Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57 LAdmitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹57 L | L1 | Admitted-Finance |
| 2 | L2₹57.0 L+₹4,100 (0.07%)Admitted-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹57.0 L+₹4,100 (0.07%) | L2 | Admitted-Finance |
| 3 | L3₹63.7 L+₹6.7 L (11.8%)Admitted-Finance | ₹63.7 L+₹6.7 L (11.8%) | L3 | Admitted-Finance |
| 4 | L4₹72.5 L+₹15.5 L (27.2%)Admitted-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹72.5 L+₹15.5 L (27.2%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S MANOJKUMAR M NAGARKATTE L3 | ANKIT SHIP REPAIRERS AND SUPPLIERS L4 | Shree Ayyappa Engineering L1 | DURGAI ELECTRICALS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down/out carefully old unserviceable UG cable (HT) /LT of any size from inside of tunnel and remove the unserviceable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and as directed. Note : Excavation and earthwork shall be measured and paid for Separately | 240 | RM | 34 ₹8,160 | 40 ₹9,600 | 20 ₹4,800 | 10 ₹2,400 Lowest |
| 2.00 | Supplying & laying including testing of XLPE insulated, armoured, heavy duty, HT UG electric cable in trenches/wall/cable tray/saddling/GI pipe or specified as per site requirement with stranded aluminum conductor 11 KV grade of 3 core 120 sqmm all as specified and directed. | 80 | RM | 1,218 ₹97,440 Lowest | 1,220 ₹97,600 | 2,500 ₹2,00,000 | 1,220 ₹97,600 |
| 3.00 | Supply, jointing & testing in repair of Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 95 Sqmm all as specified and as directed. | 2 | Each Job | 4,500 ₹9,000 Lowest | 5,000 ₹10,000 | 6,000 ₹12,000 | 5,000 ₹10,000 |
| 4.00 | Supply, jointing & testing in repair of Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 120 sqmm to 185 Sqmm all as specified and as directed. | 2 | Each Job | 5,200 ₹10,400 Lowest | 6,000 ₹12,000 | 7,000 ₹14,000 | 6,000 ₹12,000 |
| 5.00 | Supply, jointing & testing in repair Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 400 Sqmm all as specified and as directed. | 2 | Each Job | 6,600 ₹13,200 | 6,400 ₹12,800 Lowest | 8,000 ₹16,000 | 7,000 ₹14,000 |
| 6.00 | Supply, jointing & testing in repair of straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 95 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. | 2 | Each Job | 13,800 ₹27,600 | 13,000 ₹26,000 | 14,000 ₹28,000 | 10,000 ₹20,000 Lowest |
| 7.00 | Supply, jointing & testing in repair of straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core from 120 Sqmm to 185 sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. Make : Raychem Cat No HVS-3-2152 or equivalent model in makes specified in Appx B. | 2 | Each Job | 14,200 ₹28,400 | 15,000 ₹30,000 | 12,500 ₹25,000 | 11,000 ₹22,000 Lowest |
| 8.00 | Supply, jointing & testing in repair straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 400 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. | 2 | Each Job | 16,200 ₹32,400 | 16,000 ₹32,000 | 13,000 ₹26,000 | 12,000 ₹24,000 Lowest |
| 9.00 | Material and labour for Testing of faulty HT UG cable up to 400 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having minimum length of 1000 RM and pin point the fault location complete all as specified & as directed. Note: (1) In single stretch having minimum length 1000 RM whatsoever Nos of fault shall be paid as each job.(2). Fault locator Machine will be issued by department for testing purpose only. | 4 | Each Job | 5,200 ₹20,800 | 5,000 ₹20,000 Lowest | 17,000 ₹68,000 | 15,000 ₹60,000 |
| 10.00 | Material and labour for Testing of faulty HT UG cable up to 400 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having length more than 1000 RM and pin point the fault location complete all as specified & as directed. Note: (1) In single stretch having minimum length 1000 RM whatsoever Nos of fault shall be paid as each job.(2). Fault locator Machine will be issued by department for testing purpose only. | 3 | Each Job | 6,000 ₹18,000 Lowest | 6,500 ₹19,500 | 17,000 ₹51,000 | 15,000 ₹45,000 |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
29 Aug 2026, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR AND MAINTENANCE OF HT/LT DISTRIBUTION NETWORK INCLUDING BUSBAR DUCT TRUNKING AND ALLIED WORKS AT DSS 5, DSS 5A AND DSS12 INCLUDING SHORE SUPPLY AT SITE A2 OF NAVAL BASE KARWAR
2026_MES_780505_1
86137
Open Tender
Civil Works
Item Rate
KARWAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE(SB) KARWAR
₹1.4 L
Yes
2 Sept 2026
24 Jul 2026
31 Aug 2026
24 Jul 2026
29 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down/out carefully old unserviceable UG cable (HT) /LT of any size from inside of tunnel and remove the unserviceable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and as directed. Note : Excavation and earthwork shall be measured and paid for Separately | 240 | RM | 53 | ₹12,720 |
| 2 | Supplying & laying including testing of XLPE insulated, armoured, heavy duty, HT UG electric cable in trenches/wall/cable tray/saddling/GI pipe or specified as per site requirement with stranded aluminum conductor 11 KV grade of 3 core 120 sqmm all as specified and directed. | 80 | RM | 10 | ₹800 |
| 3 | Supply, jointing & testing in repair of Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 95 Sqmm all as specified and as directed. | 2 | Each Job | 11 | ₹22 |
| 4 | Supply, jointing & testing in repair of Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 120 sqmm to 185 Sqmm all as specified and as directed. | 2 | Each Job | - | - |
| 5 | Supply, jointing & testing in repair Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 400 Sqmm all as specified and as directed. | 2 | Each Job | 10 | ₹20 |
| 6 | Supply, jointing & testing in repair of straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 95 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. | 2 | Each Job | 10 | ₹20 |
| 7 | Supply, jointing & testing in repair of straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core from 120 Sqmm to 185 sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. Make : Raychem Cat No HVS-3-2152 or equivalent model in makes specified in Appx B. | 2 | Each Job | - | - |
| 8 | Supply, jointing & testing in repair straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 400 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed. | 2 | Each Job | 1 | ₹2 |
| 9 | Material and labour for Testing of faulty HT UG cable up to 400 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having minimum length of 1000 RM and pin point the fault location complete all as specified & as directed. Note: (1) In single stretch having minimum length 1000 RM whatsoever Nos of fault shall be paid as each job.(2). Fault locator Machine will be issued by department for testing purpose only. | 4 | Each Job | 1.25 | ₹5 |
| 10 | Material and labour for Testing of faulty HT UG cable up to 400 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having length more than 1000 RM and pin point the fault location complete all as specified & as directed. Note: (1) In single stretch having minimum length 1000 RM whatsoever Nos of fault shall be paid as each job.(2). Fault locator Machine will be issued by department for testing purpose only. | 3 | Each Job | 1.25 | ₹3.75 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_874296.xls
BOQ • 0.43 MB
86137Tender.pdf
Tender Documents • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .