Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.1 CrAccepted-AOC VILL FAZALPUR BEHIND FOCAL POINT NEAR RANDHAWA MASADAN JALANDHAR | JALANDHAR | JALANDHAR | PUNJAB | ₹54.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹59.5 CrRejected-Finance | ₹59.5 Cr | L2 | Rejected-Finance Not Eligible |
| 3 | L3₹66.7 CrRejected-Finance | ₹66.7 Cr | L3 | Rejected-Finance Not Eligible |
| 4 | Not Admitted-Fee/PreQual/Technical 24 MISSION COMPOUND AJMER ROAD JAIPUR 302001 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹40.2 Cr
EMD Value
₹40.2 L
Closing Date
25 Feb 2022, 3:00 pmClosed
Chief Engineer PMU JSV Mandi
Chief Engineer PMU JSV Mandi
Design Build including Civil works and Operation and Maintenance for 5 years of Rural Water Supply Scheme at District Chamba
2022_HPIPH_56191_1
3157-3206
Global Tenders
Civil Works
730 days
Chamba
as per tender documents
15 documents required · 15 mandatory
₹2,500
CE PMU Mandi
₹40.2 L
Yes
Mandi
3 Jan 2024
28 Jan 2022
25 Feb 2022
28 Jan 2022
25 Feb 2022
17 Feb 2022
8 Feb 2022
Amount
Water Treatment Plant Supply of electrical, mechanical and instrumentation components for Water Treatment Plant of capacities as specified below including campus lightning with solar panels, automation, real time monitoring of quality and quantity of water, etc. as directed by engineer in charge. All ancillary electrical and mechanical equipment and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account.
Proposed WTP near Chamera Dam - 1900 KLD Capacity
Proposed WTP at Bharari - 400 KLD Capacity
Submersible Pump Submersible Pump Supply of suitable Raw water submersible pumpset capable of handling 3000 PPM turbidity conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible motor confirming to BIS 9238-1979 with up to date amendments, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear, It should be fitted with device to take up expansion of water on heating of motor & suitable for operation on 415 (+10% ) and ( -15% ) volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range. Capacities are mentioned below
9.71 LPS with 21 M Head - 4 Nos. (At Proposed Chamera dam)
Pumping Machinery Supply of horizontal spindle, horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, with 100% stand-by of recommended makes as per BIS 1520-1980 with upto date amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors and suitable for operation on 415 (+6%) and (-10%) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors as per ISI: 325:1978 with upto date amendments read with IS 900:1972 Note 1 :- In case of non-availability of suitable centrifugal pumps for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal pumps) supply of submersible pumping machinery with 100% stand-by conforming to IS 8034 : 2018 with upto date amendments to meet the duty condition Note 2:- Supply of any other type of pumping machinery with 100% stand-by conforming to relevant IS code in case of non-availability suitable centrifugal/ submersible pumping machinery for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal/submersible pumps). It should include cost of bearing nuts, bolts and painting etc. Complete work inclusive of all taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials B33 wastage etc. It shall include providing and fixing of C.I/C. S Sluice valves of approved make and appropriate class to resist the design pressure and as per instruction of Engineer in charge. Capacities are provided below:
19.42 LPS with 770 M Head - (At Proposed PH near Proposed WTP Chamera Dam)- 1 Job
14.9 LPS with 384 M Head - (At Proposed PH near Proposed MBR Bokhri Morh-1) 1-Job
Disinfection System Supply of electrical and mechanical instrumentation work for Gaseous Chlorination Plant at MSB .Vacuum operated pressure feed gaseous chlorinator for Chlorination of water by direct feeding to water main consisting of the following ; Chlorinator capable to deliver 0-1000 gm/hr of chlorine gas comprising of spring opposed inlet valve, rate valve, flow meter remote ejector assembly with built in check valve, vacuum tubing , vent tubing and injection assembly. Booster pump set Set of 2 No. :1W+ 1SB with electric motor operated on 400/440 volt, 3 phase 50hz electric supply to suit ejector assembly of chlorinator, mounted on common base frame. Water piping from water main/UGR Set of 2 No. :1W+ 1SB to booster pump and delivery of water to elector through 20mm CPVC pipe complete with all fitting such as 20mm inlet gate valve, 20mm delivery valve, Y type strainer and solution delivery piping 20mm heavy duty PVC plumbing pipe sch 80 upto injection point before ejector assy/piping upto delivery mains. Total piping not exceeding 24 mtrs. Accessories/spares: Multi purpose cylinder Key-1 No. lead washers -6 Nos Ejector gasket-2 sets. Hose clips- 4 Nos. Ammonia Bottle – 50ml -1 No. Chlorine Cylinders: Chlorine gas Cylinder 100kg ., capacity as per BIS Duly certified by CCE Nagpur and filled with Chlorine gas. Chlorine Leak Detector with sensor and alarm. Electric Panel for booster pumps & leak detector. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Proposed Vacuum Gaseous Chlorination
SCADA Systems Supply, of electrical and mechanical devices in SCADA system for automation and real time monitoring of quantity and quality of water at water supply source, WTP (at inlet and outlet both), Pumphouses, Reservoirs, Rising Main, Gravity Main, Distribution etc. SCADA system shall be designed to remotely control, monitor, store, display, leakages and log process and equipment operating information. The SCADA system, as delivered shall operate with a fully developed control screens, database and a communication network for seamless real-time of data communication. The software shall feature an automated backup routine to protect system from loss of critical data. SCADA System to be integrated with Solar Panel Modules (especially at remote locations, where the supply of power is not available). Computers installed at central command location shall be able to monitor and control all Pumps, motor actuated sluice valve, Pressure transmitter, Water Level sensors, electromagnetic flow meter, Sub Soil water level transmitter / Hydro static type, Ultrasonic Level Transmitter, Turbidity Analyser, Residual Chlorine Sensor, PH Analyser and other devices installed on real time basis through SCADA system. Other software shall be interfaced with SCADA for conducting off-line as well as on-line computations for efficient functioning and operation as the case may be, and viewing computed results vis-à-vis observed real-time values. Automation system with real time data Provision to be installed at discharge point of the WTP, Collection Tank, MBR and service storage tanks in all lead & lifts and to the entire satisfaction of Engineer-in-charge. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Automation at Source, WTP, Pump House, Main balancing reservoir and Service reservoir for all schemes in CW-DZ01
Supply of Flexible rail cum trolly system with Structural steel trolley mounted with Raw water pumps to extract water from river Beas. Trolley arrangement shall move on Rail sections which shall be erected on RCC Bed in CC M30. Fluctuation level in water is 10 m in Height and 2.1m in Length. To permit/control the movement, Winch crab (5 MT capacity) and Wire rope arrangement shall be provided. Standard rail section (for meter gauge) as per relevant IS Code shall be used. Flexible rail cum trolley system shall be designed to work efficiently under worst daily water level fluctuations. All steel work shall be painted with approved primer and anti- corrosive paint. Nothing extra shall be paid on this account.
Description of Work / Item(s)
Amount
Plant and Mandatory Spare Parts Supplied from Abroad (b)
Plant and Mandatory Spare Parts Supplied from Within the Employer’s Country(b)
Design Services
Installation and other services during the Design–Build Period
Subtotal for the Design–Build of the Works, to be carried forward to the Letter of Price Bid
Operation Service
Other Services During the Operation Service Period
Subtotal for the Operation Service, to be carried forward to the Letter of Price Bid
Grand Total to be carried forward to Letter of Price Bid
Description of Work / Item(s)
Amount
Water Treatment Plant Supply of electrical, mechanical and instrumentation components for Water Treatment Plant of capacities as specified below including campus lightning with solar panels, automation, real time monitoring of quality and quantity of water, etc. as directed by engineer in charge. All ancillary electrical and mechanical equipment and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account.
Proposed WTP near Chamera Dam - 1900 KLD Capacity
Proposed WTP at Bharari - 400 KLD Capacity
Submersible Pump Submersible Pump Supply of suitable Raw water submersible pumpset capable of handling 3000 PPM turbidity conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible motor confirming to BIS 9238-1979 with up to date amendments, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear, It should be fitted with device to take up expansion of water on heating of motor & suitable for operation on 415 (+10% ) and ( -15% ) volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range. Capacities are mentioned below
9.71 LPS with 21 M Head - 4 Nos. (At Proposed Chamera dam)
Pumping Machinery Supply of horizontal spindle, horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, with 100% stand-by of recommended makes as per BIS 1520-1980 with upto date amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors and suitable for operation on 415 (+6%) and (-10%) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors as per ISI: 325:1978 with upto date amendments read with IS 900:1972 Note 1 :- In case of non-availability of suitable centrifugal pumps for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal pumps) supply of submersible pumping machinery with 100% stand-by conforming to IS 8034 : 2018 with upto date amendments to meet the duty condition Note 2:- Supply of any other type of pumping machinery with 100% stand-by conforming to relevant IS code in case of non-availability suitable centrifugal/ submersible pumping machinery for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal/submersible pumps). It should include cost of bearing nuts, bolts and painting etc. Complete work inclusive of all taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials B33 wastage etc. It shall include providing and fixing of C.I/C. S Sluice valves of approved make and appropriate class to resist the design pressure and as per instruction of Engineer in charge. Capacities are provided below:
19.42 LPS with 770 M Head - (At Proposed PH near Proposed WTP Chamera Dam)- 1 Job
14.9 LPS with 384 M Head - (At Proposed PH near Proposed MBR Bokhri Morh-1) 1-Job
Disinfection System Supply of electrical and mechanical instrumentation work for Gaseous Chlorination Plant at MSB .Vacuum operated pressure feed gaseous chlorinator for Chlorination of water by direct feeding to water main consisting of the following ; Chlorinator capable to deliver 0-1000 gm/hr of chlorine gas comprising of spring opposed inlet valve, rate valve, flow meter remote ejector assembly with built in check valve, vacuum tubing , vent tubing and injection assembly. Booster pump set Set of 2 No. :1W+ 1SB with electric motor operated on 400/440 volt, 3 phase 50hz electric supply to suit ejector assembly of chlorinator, mounted on common base frame. Water piping from water main/UGR Set of 2 No. :1W+ 1SB to booster pump and delivery of water to elector through 20mm CPVC pipe complete with all fitting such as 20mm inlet gate valve, 20mm delivery valve, Y type strainer and solution delivery piping 20mm heavy duty PVC plumbing pipe sch 80 upto injection point before ejector assy/piping upto delivery mains. Total piping not exceeding 24 mtrs. Accessories/spares: Multi purpose cylinder Key-1 No. lead washers -6 Nos Ejector gasket-2 sets. Hose clips- 4 Nos. Ammonia Bottle – 50ml -1 No. Chlorine Cylinders: Chlorine gas Cylinder 100kg ., capacity as per BIS Duly certified by CCE Nagpur and filled with Chlorine gas. Chlorine Leak Detector with sensor and alarm. Electric Panel for booster pumps & leak detector. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Proposed Vacuum Gaseous Chlorination
SCADA Systems Supply, of electrical and mechanical devices in SCADA system for automation and real time monitoring of quantity and quality of water at water supply source, WTP (at inlet and outlet both), Pumphouses, Reservoirs, Rising Main, Gravity Main, Distribution etc. SCADA system shall be designed to remotely control, monitor, store, display, leakages and log process and equipment operating information. The SCADA system, as delivered shall operate with a fully developed control screens, database and a communication network for seamless real-time of data communication. The software shall feature an automated backup routine to protect system from loss of critical data. SCADA System to be integrated with Solar Panel Modules (especially at remote locations, where the supply of power is not available). Computers installed at central command location shall be able to monitor and control all Pumps, motor actuated sluice valve, Pressure transmitter, Water Level sensors, electromagnetic flow meter, Sub Soil water level transmitter / Hydro static type, Ultrasonic Level Transmitter, Turbidity Analyser, Residual Chlorine Sensor, PH Analyser and other devices installed on real time basis through SCADA system. Other software shall be interfaced with SCADA for conducting off-line as well as on-line computations for efficient functioning and operation as the case may be, and viewing computed results vis-à-vis observed real-time values. Automation system with real time data Provision to be installed at discharge point of the WTP, Collection Tank, MBR and service storage tanks in all lead & lifts and to the entire satisfaction of Engineer-in-charge. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Automation at Source, WTP, Pump House, Main balancing reservoir and Service reservoir for all schemes in CW-DZ01
Supply of Flexible rail cum trolly system with Structural steel trolley mounted with Raw water pumps to extract water from river Beas. Trolley arrangement shall move on Rail sections which shall be erected on RCC Bed in CC M30. Fluctuation level in water is 10 m in Height and 2.1m in Length. To permit/control the movement, Winch crab (5 MT capacity) and Wire rope arrangement shall be provided. Standard rail section (for meter gauge) as per relevant IS Code shall be used. Flexible rail cum trolley system shall be designed to work efficiently under worst daily water level fluctuations. All steel work shall be painted with approved primer and anti- corrosive paint. Nothing extra shall be paid on this account.
Description of Work / Item(s)
Amount
Baseline survey and studies are required to be carried out using performance base benchmark indicators related to all water supply components for project planning, designing execution and operation & maintenance.
Source feasibility studies for the proposed/existing sources are to be carried out to ensure that sources are capable of meeting ultimate water requirement in sustainable manner.
Topographical Survey of all the components is required to be carried out in accordance with the requirements as per norms and guidelines.
Hydraulic as well as structural designs are to be carried out of all the components in CW-DZ01 in accordance with the provision of Technical Planning Consideration, Design Norms and Benchmark Indicators for Rural Water Supply Schemes-Himachal Pradesh (Funded Under ADB) under the direction of Engineer-in-Charge. Wherever necessary, guidelines of Manual of Water Supply and Treatment published by CPHEEO, MoUD, New Delhi and Manual for Preparation of Detailed Project Report for Rural Water Supply Schemes in published by MoDWS Feb 2013 as directed by Engineer-In-Charge. (Refer Table 3, Section 6 of the tender document for all the detail components in scheme)
Description of Work / Item(s)
Amount
Source
Intake Chamber Designing, Constructing, Testing & Commissioning of Intake Chamber for tapping water from Khad consisting of RCC Intake Chamber Cum Raw water Pumping sets including all allied Civil Works, Site development, cutting/excavation in all kinds of soils, C/o PCC/RCC dewatering etc complete as directed by engineer in charge. The rates quoted by the contractor shall be for the complete work including Geotechnical investigations. All ancilliary works and accessories required to make the Intake system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. (Refer Vol-III-Technical specifications, )
Proposed Intake Chamber at Gadana Khad - 5Kl capacity
Bridge
Designing, Constructing, Testing & Commissioning of Steel Truss Bridge across Khads/Nallahs consisting of Anchor block on either end and 32mm dia gay ropes for suspension of bridge. The work shall include all allied Civil Works, Site development, cutting/excavation in all kinds of soils, dewatering. Steel work shall be welded in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of red lead paint In beams joists, channels, angles, tees, flats with connection plates or angle cleats as in main and cross beams hip and jack rafters purlins connected to common rafters and the like. etc complete as directed by engineer in charge. Scope consists of, but not limited to, the construction of steel truss bridge dimension as specified below. The rates quoted by the contractor shall be for the complete work including Geotechnical investigations. All ancilliary works and accessories required to make the bridge fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. (Refer Vol-III-Technical specifications)
Proposed Cross Drainage Work (Steel Truss Bridge 20 mtr Span)
Rail Cum Trolley System and Winch Room
Constructing, Installation, Testing & Commissioning of Flexible rail cum trolly system with Structural steel trolley mounted with Raw water pumps to extract water from river Beas. Trolley arrangement shall move on Rail sections which shall be erected on RCC Bed in CC M30. Fluctuation level in water is 10 m in Height and 2.1m in Length. To permit/control the movement, Winch crab (5 MT capacity) and Wire rope arrangement shall be provided. Standard rail section (for meter gauge) as per relevant IS Code shall be used. Flexible ail cum trolley system shall be designed to work efficiently under worst daily water level fluctuations. All steel work shall be painted with approved primer and anti- corrosive paint. The rates quoted by the contractor shall be for the complete work including C/o Winch Room, Geotechnical investigations etc. All ancillary works and accessories required to make the Intake system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account.
Proposed Rail cum Trolly System and Winch Room at Chamera Dam
Water Treatment Plant (WTP)
Constructing, Installation, Testing & Commissioning of Water Treatment Plant of capacities as specified below, consisting of Civil, Mechanical, Electrical and Instrumentational works, Sanitary installations, Toilet, Septic tank, Guard Room, etc. The provision of real time monitoring of quantity and quality at inlet and outlet of WTP. Works shall include necessary hydraulic testing ,structural testing and all equipment testing. The components such as site development,C/o PCC/RCC Retaining walls, Breast walls, Dewatering, Inter-connecting Path, Walkway, Storm Water Drains, Scouring arrangement, Fencing, Beautification, campus lightning with inclusion of solar panel, including all allied Works complete as directed by engineer in charge. Battery Limit shall be considered as 5.00 m from the edge of the structure or the boundary of the land whichever is less. The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. (Refer Vol-III-Technical specifications)
Proposed WTP near Chamera Dam - 1900 KLD Capacity
Proposed WTP at Bharari - 400 KLD Capacity
Boundary Wall around WTP Construction of boundary wall around WTP (constructed in brickwork/ Stonemasonry/ CMU or fencing panels of standard size i.e. 1.20x1.80 ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge.
Length of Boundary Wall in mtrs
Approach Road to WTP
Construction, Testing and Commissioning of Approach road Including all allied Civil Works, cutting/excavation in all kinds of soils, C/o PCC/RCC Retaining walls, Solar powered Street Lighting etc complete as directed by engineer in charge The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account
C/O 3 mtr. Wide single lane road i/c CD works complete. Length in KM
Disinfection System
Installation, commissioning and testing of Gaseous Chlorination Plant at MSB .Vacuum operated pressure feed gaseous chlorinator for Chlorination of water by direct feeding to water main consisting of the following ; Chlorinator capable to deliver 0-1000 gm/hr of chlorine gas comprising of spring opposed inlet valve, rate valve, flow meter remote ejector assembly with built in check valve, vacuum tubing , vent tubing and injection assembly. Booster pump set Set of 2 No. :1W+ 1SB with electric motor operated on 400/440 volt, 3 phase 50hz electric supply to suit ejector assembly of chlorinator, mounted on common base frame. Water piping from water main/UGR Set of 2 No. :1W+ 1SB to booster pump and delivery of water to elector through 20mm CPVC pipe complete with all fitting such as 20mm inlet gate valve, 20mm delivery valve, Y type strainer and solution delivery piping 20mm heavy duty PVC plumbing pipe sch 80 upto injection point before ejector assy/piping upto delivery mains. Total piping not exceeding 24 mtrs. Accessories/spares: Multi purpose cylinder Key-1 No. lead washers -6 Nos Ejector gasket-2 sets. Hose clips- 4 Nos. Ammonia Bottle – 50ml -1 No. Chlorine Cylinders: Chlorine gas Cylinder 100kg ., capacity as per BIS Duly certified by CCE Nagpur and filled with Chlorine gas. Chlorine Leak Detector with sensor and alarm. Electric Panel for booster pumps & leak detector. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Proposed Vacuum Gaseous Chlorination
Pump House
Constructing, Testing & Commissioning of Pump House & Chowkidar Room at following Locations including all allied Civil Works, Electrical works, Sanitary installations, Site development, cutting/excavation in all kinds of soils, C/o PCC/RCC Retaining walls, Breast walls, Toilets, Septic Tanks, internal and External Solar powered Street lighting, External landscaping, Fire Fighting arrangement, Gantry Crane, dewatering, campus lightning with inclusion of solar panel etc complete as directed by engineer in charge The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account.
Proposed Pump House near Proposed WTP Chamera Dam in 63.15 Sqm
Proposed Pump House near Proposed MBR Bokhri Morh-1 in 63.15 Sqm
Submersible Pumps
Installation, Testing & Commissioning with automation (to be paid separately) of suitable Raw water submersible pumpset capable of handling 3000 PPM turbidity conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible motor confirming to BIS 9238-1979 with up to date amendments, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear, It should be fitted with device to take up expansion of water on heating of motor & suitable for operation on 415 (+10% ) and ( -15% ) volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- including Pump sets (working + standby), necessary piping, Control panel with starter and protections; control valves along with electrical cable etc. Capacities are mentioned below
9.71 LPS with 21 M Head - 4 Nos. (At Proposed Chamera dam)
Pumping Machinery
Installation, Testing & Commissioning of horizontal spindle, horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, with 100% stand-by of recommended makes as per BIS 1520-1980 with upto date amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors and suitable for operation on 415 (+6%) and (-10%) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors as per ISI: 325:1978 with upto date amendments read with IS 900:1972 Note 1 :- In case of non-availability of suitable centrifugal pumps for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal pumps) supply of submersible pumping machinery with 100% stand-by conforming to IS 8034 : 2018 with upto date amendments to meet the duty condition Note 2:- Supply of any other type of pumping machinery with 100% stand-by conforming to relevant IS code in case of non-availability suitable centrifugal/ submersible pumping machinery for duty conditions (duly certified from reputed principal manufacturer for non-availability of centrifugal/submersible pumps). It should include cost of bearing nuts, bolts and painting etc. Complete work inclusive of all taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials B33 wastage etc. It shall include providing and fixing of C.I/C. S Sluice valves of approved make and appropriate class to resist the design pressure and as per instruction of Engineer in charge. Capacities are provided below:
19.42 LPS with 770 M Head - (At Proposed PH near Proposed WTP Chamera Dam)- 1 Job
14.9 LPS with 384 M Head - (At Proposed PH near Proposed MBR Bokhri Morh-1) 1-Job
Water Reservoirs
Ground Level Water Reservoirs
Constructing, Testing & Commissioning RCC Circular Ground level storage reservoirs as per capacity given below at various sites including excavation in all kinds and types of strata, soil strata including dewatering in M30 design mix in foundation, walls, bottom slab , roof slab/dome with smooth finishing in 1:3 inside the tank, all allied Civil Works, Site development, cutting/excavation in all kinds of soils, C/o PCC/RCC Retaining walls, Breast walls, Sanitary works i.e., fencing, refilling and disposing of surplus stuff with in all leads and lifts, labour and material charges. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes, all pipes should be colour coded as specified in technical specification, valves of required classes and dia and all other accessories required such as MS ladders inside and outside CI cowl type ventilator, SFRC manhole covers including frames and covers (medium duty) with proper locking arrangement water level, indicator, RCC frames for all valves ventilating shafts shall also be provided including all leads and lifts as per entire satisfaction of Engineer-in-Charge. Storage tank should include water level sensor and automatic pressure controlled valves. The tanks shall be hydraulically tested for water tightness all works shall be conforming to relevant IS code. The cost of valves shall be included in the rates of tanks . Battery Limit shall be considered as 3.00 m from the edge of the structure or the boundary of the land whichever is less. The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. The work shall include supplying of 5 sets of structural design and drawings etc complete as directed by engineer in charges per relevant data sheet and scope of work.
Proposed Reservoirs
Proposed MBR Ambu - 45 KL Capacity
Proposed MBR Bokhri Morh-1 50 KL Capacity
Proposed MBR Khrididhar - 20 KL Capacity
Proposed MBR Kunah - 40 KL Capacity
Proposed MBR Madhiyar - 60 KL Capacity
Proposed MBR Tulad - 20 KL Capacity
Proposed MBR Kamlari - 25 KL Capacity
Proposed Sub Storage tank Belli - 20 KL Capacity
Proposed SR Samliyata - 20 KL Capacity
Proposed SR Anan Khaddi - 20 KL Capacity
Proposed SR Mihnu - 20KL Capacity
Proposed SR Buhana - 20KL Capacity
Proposed SR Patna Maroh - 20KL Capacity
Proposed SR Gattiyani - 20 KL Capacity
Proposed SR Bharoori - 30 KL Capacity
Proposed SR Sherpur - 50 KL Capacity
Proposed SR Chhana - 20 KL Capacity
Proposed SR Bokhri Morh-2 - 30 KL Capacity
Proposed SR IPH Store - 20 KL Capacity
Proposed SR Bus Stand - 30 KL Capacity
Proposed SR Maluda (1+2) - 55 KL Capacity
Proposed SR Pukhri-1 - 65 KL Capacity
Proposed SR Pukhri-2 - 65 KL Capacity
Proposed SR Vatika -50 KL Capacity
Proposed SR Kanda-3 - 25 KL Capacity
Proposed SR Voged - 20 KL Capacity
Proposed SR Cheli padhar - 20KL Capacity
Proposed SR Chalama - 25 KL Capacity
Proposed SR Berian - 25 KL Capacity
Proposed SR Mihal - 20 KL Capacity
Proposed SR Dangori - 30 KL Capacity
Proposed Sumpwell at Gadana - 20 KL Capacity
Retrofitting of Existing Reservoirs
Retrofitting of existing reservoirs shall include strengthening of structure, foundation, walls, bottom slab , roof slab/dome with smooth finishing in 1:3 inside the tank, Patchwork, Denting, Painting, rehabilitation of leakages in tank and pipes, provisioning of ventilation. The job shall also includes reestablishment of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes, all pipes should be colour coded as specified in technical specification, valves of required classes and dia should be re-established wherever they are disreputable. all other accessories required such as MS ladders inside and outside CI cowl type ventilator, SFRC manhole covers including frames and covers (medium duty) with proper locking arrangement water level, indicator, RCC frames for all valves ventilating shafts shall also be retrofitted including all leads and lifts as per entire satisfaction of Engineer-in-Charge. The tanks shall be hydraulically tested for water tightness all works shall be conforming to relevant IS code.
Existing MBR Kanda (1+2) - 150 KL Capacity
Existing MBR Kaned - 90 KL Capacity
Existing SR Talgoot - 10 KL Capacity
Existing SR Lahad - 15 KL Capacity
Existing SR Belli - 52 KL Capacity
Over Head Reservoirs
Proposed Reservoirs
Constructing, Testing & Commissioning R.C.C. Elevated Circular Over head storage tanks as per capacity given below at various stages/sites including excavation in all kinds and types of strata, soil strata in M30 design mix in foundation, walls, bottom slab , roof slab/dome with smooth finishing in 1:3 inside the tank, all allied Civil Works, Site development, cutting/excavation in all kinds of soils, C/o PCC/RCC Retaining walls, Breast walls, refilling and disposing of surplus stuff with in all leads and lifts, labour and material charges. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipeproper manifold at outlet including all fittings, bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside ventilator with mosquito proof wire mesh, lightening arrester complete ,SFRC manhole covers including frames and covers (medium duty) with proper locking arrangement water level indicator, RCC frames for all valves ventilating shafts shall also be provided including all leads and lifts as per entire satisfaction of Engineer-in-Charge. Storage tank should include water level sensor and automatic pressure controlled valves. The tanks shall be hydraulically tested for water tightness all works shall be conforming to relevant IS code. The cost of valves & other accessories shall be included in the rates of tanks . Battery Limit shall be considered as 3.00 m from the edge of the structure or the boundary of the land whichever is less. The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. The work shall include supplying of Five sets of structural design after testing the bearing capacity of soil and drawings, etc complete as directed by engineer in charge.
Proposed MBR Dharamshala (Staging - 15 m) - 40 KL Capacity
Boundary Wall around Reservoirs
Construction of boundary wall around water storage tanks (constructed in brickwork/ Stonemasonry/ CMU or fencing panels of standard size i.e. 1.20x1.80 ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge.
Length of Boundary Length in mtrs
Rising Main
Excavation in foundation, trenches ( for pipes & pits) up to all depths etc. in all kinds of soil such as pick work, jumper work, saturated soil including bailing and pumping out of water, blasting soft/ hard rock or chiseling or wedging out of same rock where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring strutting , planking, timbering & dewatering wherever required, stacking usable & unusable material /soil separately & after laying jointing and testing of pipes, returning the usable soil in trenches in 15 cm layers by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces, to its original condition & including cost of diversion of traffic, night signals boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge. Quantity in Cum
GMSERW Pipe 150 mm dia , Quantity in Cum
Pipe Material
Providing, laying, jointing and testing in trenches of mild steel electrical resistance welded beveled edge flanged/ Butt welded pipe confirming to ISO 3183:2007 L210 or Grade A in item as per dimensions, weight and test pressure mentioned therein code (mill tolerances to be as per relevant ISO Code) in random lengths of 6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. The laying & jointing of pipes should conform to IS:5822-1994 (earth work in trenches, flanged joint and butt-welded joints except in bends to be measured and paid separately). The pipes and specials shall have outside wrapping with galvanized as per BIS-4736, the galvanization is done by the manufacturing firm itself complete in all respect.
GMSERW Pipe 150 mm dia FT 5 MC 4.8 mm wall thickness
GMSERW Pipe 150 mm dia FT 17 MC 4.8 mm wall thickness
GMSERW Pipe 150 mm dia FT 28 MC 4.8 mm wall thickness
GMSERW Pipe 150 mm dia FT 28 MC 5.6 mm wall thickness
GMSERW Pipe 150 mm dia FT 28 MC 6.4 mm wall thickness
GMSERW Pipe 150 mm dia FT 38 MC 7.1 mm wall thickness
Flanges
Providing, welding and fixing of M.S. flanges conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) and welding of MS flanges with GMS/MSERW pipes in two layers on both faces i.e. two layer on outer faces and one layer on inner faces to make the joint leak proof (The cost of proving and layer of MSERW pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge with in all leads and lifts.
M.S. Flange 150 mm dia. FT 5, Qty in pair
M.S. Flange 150 mm dia. FT 17, Qty in pair
M.S. Flange 150 mm dia. FT 28, Qty in pair
M.S. Flange 150 mm dia. FT 38, Qty in pair
Butt Weld
Providing circumferential butt welded joints by electrical arc welding to below mentioned dia and wall thickness MSERW pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ES/ESAB make, conforming to IS 814-1991 including Die penetration test, at site of work complete in all respects, including manual/mechanical handling of pipe in all leads and lifts to the entire satisfaction of Engineer in charge.
Butt welding 150 mm dia pipe with 4.8 mm wall thickness (Per Joint)
Butt welding 150 mm dia pipe with 5.6 mm wall thickness (Per Joint)
Butt welding 150 mm dia pipe with 6.4 mm wall thickness (Per Joint)
Butt welding 150 mm dia pipe with 9.5 mm wall thickness (Per Joint)
Valves
Providing and fixing double flanged Cast Iron Non Rising Sluice Valve Flanged End As Per IS : 14846, Body, Dome, Wedge- CI IS:210, Gr. FG260, Body & Wedge Rings- Bronze IS:318 Gr. LTB2, Spindle- SS IS:6603, Gr.12Cr12, Gland Packing- Greasy Jute Packing, Fasteners- CS IS:1367, CL-4.6/4.0, Gasket- Natural Rubber, Flange Drilling - IS:1538, Table 4 & 6 i/c carriage in all leads & lifts & complete in all respect a as per direction and to the entire satisfaction of Engineer-in-Charge.
150 mm dia PN-1.0
Providing and fixing double air valve (Isolating type) Double orifice with rubber ball 50 mm dia dia of Bir make confirming to BIS:14845 with upto date amendments in rising mains with upto date amendments as per direction and to the entire satisfaction of Engineer-in-Charge.
50 mm dia PN1.0
Anchor blocks
Excavation in foundation, trenches (for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chiselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, levelling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unusable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of engineer-in-charge. Quantity in Cum.
Providing and laying cement concrete 1:4:8 (1 cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts and to the entire satisfaction of Engineer-in- charge. Quantity in Cum.
Providing and laying cement concrete 1:2:4 (1 cement:2 sand:4 graded crushed stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced work in:- Foundation and plinth Quantity in Cum.
Providing form work with steel plates 3.15mm thick welded with angle iron frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4mtr. and removal of the same for insitu -reinforced concrete and plain concrete work in :
Foundation and footings. Quantity in Sqm
Providing tor steel reinforcement for reinforced cement concrete work including bending binding and placing in position complete including the cost of binding wire in all leads and lifts. In KG
Gravity Mains
Excavation in foundation, trenches ( for pipes & pits) up to all depths etc. in all kinds of soil such as pick work, jumper work, saturated soil including bailing and pumping out of water, blasting soft/ hard rock or chiseling or wedging out of same rock where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring strutting , planking, timbering & dewatering wherever required, stacking usable & unusable material /soil separately & after laying jointing and testing of pipes, returning the usable soil in trenches in 15 cm layers by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces, to its original condition & including cost of diversion of traffic, night signals boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge. Quantity in Cum
50 mm Dia GI Pipe, Quantity in Cum
65 mm Dia GI Pipe, Quantity in Cum
80 mm Dia GI Pipe, Quantity in Cum
100 mm Dia GI Pipe, Quantity in Cum
200 mm Dia GI Pipe, Quantity in Cum
Pipe Material
Providing, laying, jointing and testing in trenches (to level or grade) of GI pipes Medium Class of below diameter conforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade, suitable to withstand required hydraulic test pressure in random length 4m-6m with plain ends The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect as per the direction and entire satisfaction of Engineer-in Charge. ( Cost of earth work and joints to be measured and paid separately )
50 mm Dia GI Pipe Medium class
65 mm Dia GI Pipe Medium class
80 mm Dia GI Pipe Medium class
100 mm Dia GI Pipe Medium class
200 mm Dia GI Pipe Medium class
Flanges
Providing welding and fixing of M.S. flanges conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) and welding of MS flanges with GMS/MSERW pipes in two layers on both faces i.e. two layer on outer faces and one layer on inner faces to make the joint leak proof. The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge with in all leads and lifts.
M.S. Flange 50 mm dia, Per Pair
M.S. Flange 65 mm dia, Per Pair
M.S. Flange 80 mm dia, Per Pair
M.S. Flange 100 mm dia, Per Pair
M.S. Flange 200 mm dia, Per Pair
Butt Weld
Providing circumferential butt welded joints by electrical arc welding to below mentioned dia and wall thickness pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm, conforming to IS 814-1991 including Die penetration test, at site of work complete in all respects, including manual/mechanical handling of pipe in all leads and lifts to the entire satisfaction of Engineer in charge.
Butt welding 50 mm dia pipe
Butt welding 65 mm dia pipe
Butt welding 80 mm dia pipe
Butt welding 100 mm dia pipe
Butt welding 200 mm dia pipe
Valves
Providing and fixing Gun Metal Gate Valve, Screwed in bonnet, Inside Screw, non rising stem, Integral seats, Handwheel operated, Flanged ends, conforming to IS : 778 - 1984 Class - 1, valves are blue painted. Testing of Valves is done as per specification under clause - 9 of IS : 778 -1984, The hydraulic Test pressures are indicated below :- Body Test Pressure = 1.5 MPa Hyd. Seat & Backseat Test Pressure = 1.0 MPa Hyd., i/c carriage in all leads & lifts & complete in all respect a as per direction and to the entire satisfaction of Engineer-in-Charge.
50 mm dia PN-1.0 , in Nos.
65 mm dia PN-1.0 , in Nos.
80 mm dia PN-1.0 , in Nos.
100 mm dia PN-1.0 , in Nos.
Providing and fixing double flanged Cast Iron Non Rising Sluice Valve Flanged End As Per IS : 14846, Body, Dome, Wedge- CI IS:210, Gr. FG260, Body & Wedge Rings- Bronze IS:318 Gr. LTB2, Spindle- SS IS:6603, Gr.12Cr12, Gland Packing- Greasy Jute Packing, Fasteners- CS IS:1367, CL-4.6/4.0, Gasket- Natural Rubber, Flange Drilling - IS:1538, Table 4 & 6 i/c carriage in all leads & lifts & complete in all respect a as per direction and to the entire satisfaction of Engineer-in-Charge.
200 mm dia PN-1.0 , in Nos.
Providing and fixing double air valve (Isolating type) Double orifice with rubber ball 50 mm dia dia of Leader/Kirloskar make confirming to BIS:14845 with upto date amendments in rising mains with upto date amendments as per direction and to the entire satisfaction of Engineer-in-Charge. PN-1.0
50 mm dia PN-1.0, in Nos.
Providing and fixing double PRV valve complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge.
50 mm dia PN-1.0, in Nos.
65 mm dia PN-1.0, in Nos.
80 mm dia PN-1.0, in Nos.
200 mm dia PN-1.0, in Nos.
Distribution Mains
Excavation in foundation, trenches ( for pipes & pits) up to all depths etc. in all kinds of soil such as pick work, jumper work, saturated soil including bailing and pumping out of water, blasting soft/ hard rock or chiseling or wedging out of same rock where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring strutting , planking, timbering & dewatering wherever required, stacking usable & unusable material /soil separately & after laying jointing and testing of pipes, returning the usable soil in trenches in 15 cm layers by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces, to its original condition & including cost of diversion of traffic, night signals boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge. Quantity in Cum
Pipe Material
Providing, laying, jointing and testing in trenches (to level or grade) of GI pipes Light Class jointed of below diameter conforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade, suitable to withstand required hydraulic test pressure in random length 4m-6m with screw and socketed. The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect as per the direction and entire satisfaction of Engineer-in Charge. ( Cost of earth work and joints to be measured and paid separately )
25 mm dia GI Pipe Light class, Length in Rmt
32 mm dia GI Pipe Light class, Length in Rmt
40 mm dia GI Pipe Light class, Length in Rmt
50mm dia GI Pipe Light class, Length in Rmt
Providing, laying, jointing and testing in trenches (to level or grade) of GI pipes Medium Class jointed of below diameter conforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade, suitable to withstand required hydraulic test pressure in random length 4m-6m with plain ends. The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect as per the direction and entire satisfaction of Engineer-in Charge. ( Cost of earth work and joints to be measured and paid separately )
65 mm Dia GI Pipe Medium class, Length in Rmt
80 mm Dia GI Pipe Medium class, Length in Rmt
100 mm Dia GI Pipe Medium class , Length in Rmt
Flanges
Providing welding and fixing of M.S. flanges conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) and welding of MS flanges with GMS/MSERW pipes in two layers on both faces i.e. two layer on outer faces and one layer on inner faces to make the joint leak proof (The cost of proving and layer of MSERW pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge with in all leads and lifts.
M.S. Flange 65 mm dia, Per Pair
M.S. Flange 80 mm dia, Per Pair
M.S. Flange 100 mm dia, Per Pair
Butt Weld
Providing circumferential butt welded joints by electrical arc welding to below mentioned dia and wall thickness GI pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ES/ESAB make, conforming to IS 814-1991 including Die penetration test, at site of work complete in all respects, including manual/mechanical handling of pipe in all leads and lifts to the entire satisfaction of Engineer in charge.
Butt welding 65 mm dia pipe
Butt welding 80 mm dia pipe
Butt welding 100 mm dia pipe
Valves
Providing and fixing Gun Metal Gate Valve, Screwed in bonnet, Inside Screw, non rising stem, Integral seats, Handwheel operated, Flanged ends, conforming to IS : 778 - 1984 Class - 1, valves are blue painted. Testing of Valves is done as per specification under clause - 9 of IS : 778 -1984, The hydraulic Test pressures are indicated below :- Body Test Pressure = 1.5 MPa Hyd. Seat & Backseat Test Pressure = 1.0 MPa Hyd., i/c carriage in all leads & lifts & complete in all respect a as per direction and to the entire satisfaction of Engineer-in-Charge.
40 mm dia PN-1.0
50 mm dia PN-1.0
65 mm dia PN-1.0
80 mm dia PN-1.0
100 mm dia PN-1.0
Providing and fixing double PRV valve complete in all respect a as per direction and to the entire satisfaction of Engineer-in-Charge.
40 mm dia PN-1.0
50 mm dia PN-1.0
65 mm dia PN-1.0
80 mm dia PN-1.0
Restoration of road damages due to digging for laying of various dia pipe line in difference RD.s with surface and base coarse as in the existing road alignment. Construction of road should be as per the direction and to entire satisfaction of Engineer-in-charge. Length in Rmt
Water Meter and Connection at consumer end
Providing and installation of house connections with 15 mm dia GI pipe, 30 Rmtr. (Light class) i/c 80 mm nipple of 15mm dia, GI socket, GI Union , GI elbow and 1/4" ferrule connection . Quantity in Nos.
Providing and fixing of Domestic type AMR compatible (electronic) water meters from 15 mm to 32 mm sizes shall be magnetically coupled, Multi jet, inferential type, dry dial, IP68 class protection, class B water meters (screwed ends) manufactured in accordance with ISO: 4064-2005 (revised in 2014) standards & have ISI/ EEC/ MID marking on meter dial for each size with nut and nipple set. Quantity in Nos.
15mm Quantity in Nos.
20mm Quantity in Nos.
25 mm Quantity in Nos.
32 mm Quantity in Nos.
SCADA Systems Constructing, Testing & Commissioning of electrical and mechanical devices in SCADA system for automation and real time monitoring of quantity and quality of water at water supply source, WTP (at inlet and outlet both), Pumphouses, Reservoirs, Rising Main, Gravity Main, Distribution etc. SCADA system shall be designed to remotely control, monitor, store, display, leakages and log process and equipment operating information. The SCADA system, as delivered shall operate with a fully developed control screens, database and a communication network for seamless real-time of data communication. The software shall feature an automated backup routine to protect system from loss of critical data. SCADA System to be integrated with Solar Panel Modules (especially at remote locations, where the supply of power is not available). Computers installed at central command location shall be able to monitor and control all Pumps, motor actuated sluice valve, Pressure transmitter, Water Level sensors, electromagnetic flow meter, Sub Soil water level transmitter / Hydro static type, Ultrasonic Level Transmitter, Turbidity Analyser, Residual Chlorine Sensor, PH Analyser and other devices installed on real time basis through SCADA system. Other software shall be interfaced with SCADA for conducting off-line as well as on-line computations for efficient functioning and operation as the case may be, and viewing computed results vis-à-vis observed real-time values. Automation system with real time data Provision to be installed at discharge point of the WTP, Collection Tank, MBR and service storage tanks in all lead & lifts and to the entire satisfaction of Engineer-in-charge. The rates quoted by the contractor shall be for the complete work including carriage and insurance charges.
Automation at Source, WTP, Pump House, Main balancing reservoir and Service reservoir for all schemes in CW-DZ01
Health, Safety, Environmental (HSE) and Social requirementse
Air quality Monitoring
Noise Levels Monitoring
Surface Water Monitoring
Consent for establishments & consent for operation from HPPCB.
Provision for tree cutting & compensatory plantation measures
Preparation of plans and protocols (traffic management plan, waste (spoils) management plan etc.
Civil Works (Water Sprinkling for dust suppression; Barricading; etc)
Cost estimates for specific Biodiversity Mitigation Measures
Contractors Orientation to Workers on EMP implementation & COVID-19 protocol
EMP implementation costs for EMP measures that are not part of generation construction practices, and/or not covered under 18.01 to 18.10 f
Provisional Sum for STI/STD and HIV/AIDS alleviation programmeb (* It is a non competitive amount and contractor should enter the sum INR 2,00,000 without any alteration)
Percentage of item 18 for Contractor’s overhead charges and profit (10%)
Provisional Sum for the Employer’s share of the Dispute Adjudication Boardd (* It is a non competitive amount and contractor should enter the sum INR 5,00,000 without any alteration)
Description of Work / Item(s)
Amount
Foreign currency 1 (if any)
Bid price (INR)
Description of Work / Item(s)
Amount
Fixed Price * Operation and maintenance of schemes from source to Tail end of the scheme in proper working condition. O&M includes the regular i.e., daily supply of designed/required quantity of potable water having water quality as per of water supply standard/protocol to the beneficiaries of the schemes up to main storage/delivery tank, from source to WTP, Main sector storage tanks at different locations as per plan and repair and maintenance of main lines. Gravity Lines, and entire distribution system along with maintenance of SCADA system of schemes. Regular maintenance of all the facilities including cleaning, washing, oil and greasing repair, replacement of worn out/damaged part of pumping machinery. Pipeline, valves and electrical, Mechanical requirements, regular cleaning of all structures like storage tanks, sumpwells, intakes, channels, collection/distribution channels/pump house etc. and the disposal of the same as per the direction of the Engineer-in-charge. It includes fixing /repairing/leakage in structure, channel, pipeline, pumping machinery etc. & proper distribution of treated water and regular testing of water samples and required stages of treatment. Keeping regular and proper record of water quantity and quality, repair and maintenance work, chemical dosing and time and hours of run of pumping machinery, removal of all kind of slips, slush, uprooting of unwanted grass, shrubs, weeds etc growing near the structure and keeping the area neat and clean to the entire satisfaction of Engineer-in-charge. Maintenance of site development components including boundary walls and approach road need to be done. Planting and maintaining plants of the flowers/trees around the Pump Houses/ WTP/Storage tanks/Sump wells etc. to the entire satisfaction of Engineer-in-charge. It includes the cost of procurement of adequate and proper tools and plants, skilled & unskilled manpower, spare-parts, oil, grease, lubricants, chemicals and all kinds of regents required for water sample testing, refilling of gaseous cylinders including mechanical and head load carriage etc. and making standby arrangement all times, instruments, equipment, stationary and any other material etc. required for O& M excluding the cost of energy charges. All the operations shall be carried out as per the CPHEEO Manual of the water supply. The details of water supply infrastructure is provided in Table 3 of section 6 of this tender document.
Local Currency
Foreign currency 1 [if any]
Description of Work / Item(s)
Amount
Fixed Price
Guaranteed Maximum Energy Consumption Rate for the facility in kWh per unit of production
Nominal Average Tariff in INR per kWh from the local grid (a) (*for the purpose of this entry all bidders shall quote uniform tariff rate of Electricity at a rate of INR 4.2 per kWh)
Description of Work / Item(s)
Amount
Part B: Contractor’s Electricity Payment by Employer Power consumption will include total consumption of electricity that shall be made by all the components i.e Power consumption by Pumps, WTP, Disinfectant System, Pumphouse, SCADA System, Campus lighting and any other material that requires electricity in the below mentioned schemes. All power consumption by ancillary works and accessories required to make the system fully functional shall be included in the cost of power. Nothing extra shall be paid on this account.
Annual production (forecast)
Annual electricity consumption (kWh) (Line 1 x Bidder’s Guaranteed Maximum Energy Consumption Rate in Part A)
Annual Contractor’s Electricity Payment in local currency (Line 2 x Nominal Average Tariff in Part A)
Description of Work / Item(s)
Amount
Health, Safety, Environmental (HSE) and Social requirementse
Air quality Monitoring
Noise Levels Monitoring
Surface Water Monitoring
Consent for establishments & consent for operation from HPPCB.
Provision for tree cutting & compensatory plantation measures
Preparation of plans and protocols (traffic management plan, waste (spoils) management plan etc.
Civil Works (Water Sprinkling for dust suppression; Barricading; etc)
Cost estimates for specific Biodiversity Mitigation Measures
Contractors Orientation to Workers on EMP implementation & COVID-19 protocol
EMP implementation costs for EMP measures that are not part of generation construction practices, and/or not covered under 1.01 to 1.9 f
Provisional Sum for STI/STD and HIV/AIDS alleviation programmeb (* It is a non competitive amount and contractor should enter the sum INR 2,00,000 without any alteration)
Percentage of item 1 for Contractor’s overhead charges and profitc (10%)
Provisional Sum for the Employer’s share of the Dispute Adjudication Boardd (* It is a non competitive amount and contractor should enter the sum INR 5,00,000 without any alteration)
R.G. INDUSTRIES
Unipro Techno Infrastructure Pvt Ltd
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
R.G. INDUSTRIES
A V RAMBABU INFRA PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid