Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC HOUSE NO 54 PUBERUN PATH HATIGAON GUWAHATI 781038 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.3 L+₹30,126.57 (0.91%)Rejected-Finance SUMATEE BHAWAN GUWAHATI AIRPORT NEAR BORJHAR TELEPHONE EXCHANGE GUWAHATI 781015 ASSAM | KAMRUP METRO | ASSAM | 781015 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.0 L+₹91,934.77 (2.78%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹36.6 L+₹3.6 L (10.9%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹36.0 L
EMD Value
₹71,900
Closing Date
8 Aug 2023, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
PROVN OF TOILET NEAR BLDG NO P 253 SECURITY LIGHTS WITH POLE AND SPL REP TO BLDG NO T 05 MT SHED UNDER GE NARANGI
2023_MES_608399_1
8892/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹71,900
Yes
26 Sept 2023
8 Jul 2023
12 Aug 2023
8 Jul 2023
8 Aug 2023
21 Jul 2023
Amount
Excavation in trenches n.exc 1.5m wide and not exceeding 1.5 m in depth for foundation etc, or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil etc complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and depth exceeding 1.5 m but not exceeding 3.00m beyond the forst 1.50m etc, or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil etc complete all as specified and as directed.
M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed.
M&L surface dressing not exceeding 15 cm deep and complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil etc complete all as specified and as directed.
Removing of surplus excavated material not exc 50m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and as directed.
M&L sand filling under floors including watering and consolidation complete all as specified and as directed.
Supply and laying 150 micron polythene film, black, laid in floor between sand and sub base complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge not exceeding 63mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed.
M/L PCC 1:3:6 type C-2 ( 40mm graded aggregate) as in concrete bed to drain pipe 110 mm dia including packing under , and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L Precast RCC1:2:4 Type B-1 ( Using 20mm graded stone aggregate) as in landings, cover slabs ( for manhole etc) chullah hoods, chajjas , water toughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation filliing and mass concrete complete all as specified and as directed.
M&L PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) in surface channel and drain including form work complete all as specified and as directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) in coping/benching including form work complete all as specified and as directed.
M&L for RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete etc complete all as directed.
M&L for RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in Columns, pillars, piers, posts and struts etc.complete all as specified as directed.
M&L for RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in beams, seimic bands, cantilevers, bressumers and lintels complete all as specified as directed.
M&L RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in slabs supported on walls , beams and columns in floors, roofs, landings, balconies, casnopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in chajja complete all as specified and directed.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified as directed.
M&L Formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified as directed.
M&L Formwork to chajjas, chullahoods, troughs and similar items including edges complete all as specified as directed.
M&L Formwork to concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified as directed.
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L TMT steel bars 8mm dia cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for mild steel TMT bars 6 mm dia and over upto and including 8mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
M&L for brick work with old size sub class 'B' bricks straight or curved on plan exc. 6m mean radius and built in CM 1:6 etc complete all as specified as directed.
M & L for half brick work with sub class 'B' bricks old size (locally available best quality) straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed.
M & L 40mm thick damp proof course 1:2:4 type B-0 and applying evenly a tack coat of blown bitumen 85/25 @ 1.20 kg/sqm binding with clean dry sand @ 0.05cum/sqm and laying 150micron thick polythene film complete all as specified and as directed.
M & L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 mixed with water ptoofing compound @ 3% of weight of cement or as per manufactures instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (ii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (iv) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
S&F 30 mm thick Factory Made Solid Panel PVC Door Shutter consisting of frame made out of M.S. tubes of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet 5mm thick ‘C’ channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side, and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s instructions and drawing. The width of stiles & rails will be in proportion to the width of the door shutter as per SSR Clause No 8B.2.1
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing etc complete all as directed.
S & F steel ventilators and windows fixed type , with glazing bars dovetailed or welded ready for wire mesh/glass pan fixing complete all as specified and as directed.
S&F mild steel Framed work such as grills, gratings, angle iron, mild steel sheets, mild steel round bar, MS flat iron etc.. for chowkhats or doors shutters or windows etc with ends of bars shouldered and/or riveted, wlded or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F 100mm size stainless steel butt hinges, medium weight, and fixed etc complete all as directed.
S&F 200 mm size aluminum anodised, barrel tower bolts of extruded section etc complete all as directed.
S&F 125 mm extruded aluminum alloy handles, cast type, anodized all as specified and directed.
S & F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F in repair stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, quality or description) from wooden/steel frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S & F4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane frosted on both sides complete all as specified and as directed.
S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges and hips.
M & L for 25 mm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregates) as in levelling course complete all as specified and as directed.
M & L for 100 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in sub base complete all as specified and as directed.
M & L for coloured Non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 450x300x7mm/350X250X7mm thick / 300X450X7mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
M&L Prepolished cement concrete chequrred tiles coloured of size 20cmx20cmx25mm thick machine pressed , set and jointed and pointed in neat cement slurry with grey cement and pigments including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on fair faces of RCC concrete surfaces and including applying cement slurry in bottom of slab, chajjas, fin, facias etc. complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 2% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
S&F aluminium anodised 20mm dia tubular curtain rod including brackets, stops, rollers etc. complete all as specified and as directed
S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for preparation of old steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed.
S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F GI tubing 20 mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Cutting into existing manholes for connecting new drain pipe of any size making good to pipe and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 th section) in cement concrete 1:2 :4 type B-1 smooth finished and reforming benching as required for 150mm dia ( internal ) pipe complete all as specified and directed.
S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S&F stop valves/ angular stop valve, 20mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.
S&F Bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F , 15mm dia stop valves stop cast copper alloy, fancy type, chromium plated with long shank and cup ( concealed type) complete all as specified and as directed.
S & F 15 mm bore pillar taps, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
S&F vitreous china bowl, urinal flat back, size of 465X 355 X 265 mm white ( minimum) with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc. complete all as specified and directed.
S&F vitreous china urinal partition white fixed to wall with necessary accessories. complete all as specified and directed.
S & F vitreous china, wash hand basin, white coloured, flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed
S&F brass chromium plated tubular towel rail of 20mm dia and 60cm in length, D shaped, with brass chromium plated brackets complete all as specified and as directed.
S&F stainless steel grating doom 100mm dia complete all as specified and as directed.
S&F CI floor trap75mm outlet with grating including jointing to waste pipe fixed in cement concrete type B-1 ( 1:2:4). complete all as specified and directed.
S&Fchromium plated soap dish of approximate size 160x160x90mm embedded in wall complete all as specified & as directed.
S&Fhealth faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection and fixing in position complete all as specified & as directed.
S&F PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets complete all as specified and directed.
S&F 32 mm dia PVC waste pipe including coupling complete all as specified and as directed.
S&F PVC connections 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed.
S & F vitreous china wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed
S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed
S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed
S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall, ceiling or laid in floor complete all as specified and directed
S & F 110mm PVC ( SWR) j P or S trap complete all as specified and directed.
S&F 75mm dia PVC (SWR) vent cowl complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) bends of any radius complete all as specified and directed
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 laid and fixed including PVC rigid conduit with all accessories including febricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screws for mounting switches, sockets, regulators etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 94 here-in-before but for one 3 pin 5 Amp switch socket outlet on same board with other switches.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as specified and as directed.
S&F switch piano, flush type single pole one way 15 Amps 240 volt complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F in repair saucer nextgen highbay light of 100 W LED with energy saving with PDC housing suitable for ceiling ( surface/suspended) mounting and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repair LED light fitting of approved make 1X 20 W, 220V, AC decorative batten type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F LED light fitting of approved make 1X 20 W, 220V, AC decorative batten type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repairs, LED35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .
Supply and fixing LED street light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection .
M&L for building secruity light bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 2.0 mtrs complete all as specified and directed.
M&L for street light bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 1.50 mtrs including two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F street light junction box of size 250mmX200mmX105mm made of high quality sheet moulding compound with IP 66 protection ( Dust and vermin proof as per IEC 60529) totally insulated with MCB, DP, 10 KA, 6 Amps to be fixed on Din rail, with locking arrangement with cable gland suitable upto 16 sqmm cable and necessary fixing arrangements such as clamps, nuts, bolts etc complete all as specified and as directed.
S&F LED light fitting of approved make mirror type with high output diffuser 2 feet, 10 W, 220V, AC decorative type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed .
S & F SPN DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed.
S & F in repair SPN DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed.
S&F MCBs,TPN 40 to 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F MCBs, SPN 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F of Exhaust fan made of sturdy Engineeering plastic complete with louver shutter, 230V, 50 Hz, RPM 1200 300mm sweep copper winding complete all as specified and directed.
Supply, laying and testing of XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches / floor or fixed on wall /pole with brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading fine dry river sand for cushing to UG cable including spreading levelling and hand punning etc complete all as specified and directed.
M&L for sub class 'B' old size bricks laid in trenches for cable protection laid flat width wise along the length of cable complete all as specified and directed.
M& L for Manual boring under roads / hard standing by required T&P without disturbing the top surface of the road for passing the cable in GI Pipe of 40 mm to 80mm dia complete all as specified and as directed.
M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors, complete all as speciffied and as directed
M&L for erection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface complete all as specified and as directed.
M&L connecting junction box to street light luminaire using wiring with two runs (P-N) single core 1.5 sqmm ( nominal area) FR PVC insulated and unsheathed multistranded copper conductor cable 1100 V grade and one run of FR PVC insulated and unsheathed multistranded copper conductor cable of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit and tiding the same with aluminium strip with the pole complete all as specified and directed. Note: ( Two single core 1.5 sqmm cable and one single core 1.5sqmm earth conductor cable and one run of PVC conduit shall be measured as one run).
M&L in repair Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit all together shall be measured as one unit.)
M&L Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit all together shall be measured as one unit.)
M&L in repair Sub main wiring with 2 runs of 2.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit all together shall be measured as one unit.)
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 with and including demolition of old earthing..
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 .
Ms Sukumar Talukdar and Co.
SHANKAR ENTERPRISE
M/S Bharat Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .