Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | ₹1.0 Cr | 1 | Accepted-AOC bidder is L1 |
| 2 | 2₹1.1 Cr+₹2.1 L (2.03%)Rejected-AOC 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹1.1 Cr+₹2.1 L (2.03%) | 2 | Rejected-AOC bidder is L2 |
| 3 | 3₹1.2 Cr+₹14.3 L (13.9%)Rejected-AOC | ₹1.2 Cr+₹14.3 L (13.9%) | 3 | Rejected-AOC bidder is L3 |
| 4 | 4₹1.2 Cr+₹20.6 L (19.9%)Rejected-AOC 86 SECTOR 07 URBAN ESTATE KURUKSHETRA | ₹1.2 Cr+₹20.6 L (19.9%) | 4 | Rejected-AOC bidder is L4 |
| 5 | Not Admitted-Fee/PreQual/Technical 708 PREM NAGAR KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
1 Jul 2020, 5:00 pmClosed
Executive Engineer, HTC, Chandigarh
Haryana Tourism Corporation, SCO-17-18-19, Sector-17B, Chandigarh
Development of Tourism Infrastructure at places related to Mahabharat in Kurukshetra under Krishna Circuit (Work for proposed electrification of ghats at Braham Sarovar, Kurukshetra)
2020_HBC_131149_1
HTC-2020/EW/2832
Open Tender
Civil Works
Multi-stage
180 days
Kurukshetra
Please refer Tender documents.
2 documents required · 2 mandatory
₹17,700
Haryana Tourism Corporation Ltd
₹2.4 L
Yes
28 Jul 2020
10 Jun 2020
2 Jul 2020
10 Jun 2020
1 Jul 2020
10 Jun 2020
Amount
Wiring in 1.5 sqmm PVC insulated copper conductor cable, single core, 1100 volts in 25mm dia PVC pipe, Heavy gauge, ISI mark with modular accessories and GI sheet steel modular boxes of required size with modular inner & outer face plates complete (flushed). Modular accessories should be either of make Legrand ( Mosaic) / Anchor (Wood) / ABB (Classic) only. The work should be completed as per satisfaction of Engineer-in-charge / Architect. (II) Light Point :-
(i) short point
(ii) Medium point
(iii) Long point
Supply of 500mm RGB Linear wall washer 20 +/- 1 W with with CV driver for proper driving of LEDs With Extruded Aluminium Housing(powder coated).Tempered Frosted Step Glass with IP Protection of IP6.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70.. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . .Fixture have beam angle of 30 degree.Including all accessories. Wipro Cat. No LF01-181-030-CC-05/ Philips Color Kinects Intel Hue Color Graze Powercore/Ligman/Trilux(Jali of Sarovar Temple)
Driver ( Wipro Cat. Code :LPV-100-24 / Equivalent in Philips /Ligman)
DMX controller ( Wipro Cat. Code :LG70-360-3M-24V / Equivalent in Philips /Trilux)
T connector 4C ( Wipro Cat. Code :C-T-4C-IP67 / Equivalent in Philips /Trilux)
S connector 4C ( Wipro Cat. Code :C-S-4C-IP67 / Equivalent in Philips /Trilux)
Supply, Carriage, Installation, Testing and Commissioning of RGB Mini Flood Light 12 +/- 1 W with minimum system lumens 1020 lm with CV driver for proper driving of LEDs constructed from aluminium die cast (powder coated).Tempered Frosted Step Glass with IP Protection of IP66.The LEDs used in the product shall be of reputed make like Citizen Japan / Nichia Japan/Osram/Cree/Everlight with minimum LED efficacy of 140lm/W LED with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 3000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 3kV with Colour Changing Solutions .Fixture have beam angle of 30 degree including fixing the fitting as per site requirement with cost of other petty material including labour required. The work should be completed as per satisfaction of Engineer-in-charge / Architect. Wipro Cat. No LF04-181-030-CC-XX/ equivalent in eW Burst Power Core Gen 2 Philips Color Kinetics/Ligman/Trilux.(Sikhar)
Supply, carriage, erection, testing and commissioning the following as per requirement of LED Fittings complete in all respects to the satisfaction of Engineer-in-charge / Architect.
Driver ( Wipro Cat. Code :LPV-60-24 / Equivalent in Philips /Trilux)
DMX controller ( Wipro Cat. Code :LG70-360-3M-24V / Equivalent in Philips /Trilux)
T connector 4C ( Wipro Cat. Code :C-T-4C-IP67 / Equivalent in Philips /Trilux)
S-Connector ( Wipro Cat. Code :C-S-4C-IP67 / Equivalent in Philips /Trilux)
Supply, Carriage, Installation, Testing and Commissioning of RGB Led flexi strip light 10W/ Meter(4Mtr Spool) with CV driver for proper driving of LEDs. IP Protection of IP68. Including all accessories. (Wipro Cat. No LS27-005-120-CC-50/ Philips Color Kinects iColor Flex LMX gen 2/Ligman/Trilux)(Entrance Gate)
Driver ( Wipro Cat. Code :ELG-240-24 / Equivalent in Philips /Trilux)
DMX controller ( Wipro Cat. Code :LG70-360-3M-24V / Equivalent in Philips /Trilux)
T connector 4C ( Wipro Cat. Code :C-T-4C-IP67 / Equivalent in Philips /Trilux)
S-Connector ( Wipro Cat. Code :C-S-4C-IP67 / Equivalent in Philips /Trilux)
Supply, Carriage, Installation, Testing and Commissioning of RGB Inground LED Light 18 +/- 1 W with minimum system lumens 1080 lm with CV driver for proper driving of LEDs constructed from aluminium die cast (powder coated).Tempered Frosted Step Glass with IP Protection of IP67.The LEDs used in the product shall be of reputed make like Citizen Japan / Nichia Japan/Osram/Cree/Everlight with minimum LED efficacy of 140lm/W LED with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 3000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V. Fixture have Surge Protection 3kV with Colour changing solution in RGB.Fixture have beam angle of 15/30 degree.Including all accessories. (Wipro Cat. No LI20-231-030-CC-XX/ Philips Color Kinetics Colorburst Compact PowerCore/Trilux/Ligman)(Pillars)
Driver ( Wipro Cat. Code :LPV-100-24 / Equivalent in Philips /Trilux)
DMX controller ( Wipro Cat. Code :LG70-360-3M-24V / Equivalent in Philips /Trilux)
T connector 4C ( Wipro Cat. Code :C-T-4C-IP67 / Equivalent in Philips /Trilux)
S-Connector ( Wipro Cat. Code :C-S-4C-IP67 / Equivalent in Philips /Trilux)
Supply, Carriage, Installation, Testing and Commissioning of 3-Channel Main Controller 24/ 48VDC input/output, max. 360W(24/ 48V).Including all accessories such as 1 no BPS 8UK , 1 no POE , 2 Nos PSU and 1 No Expander as per Requirement complete in all respects to the entire satisfaction of EIC / Architect. (Wipro Cat. No : LG70-360-3M-24V/ Equivalent in Philips Color Kinetics/Trilux/Ligman)
Supply, Carriage, Installation, Testing and Commissioning of Flood LED Light 58 +/- 1 W with minimum system lumens 2320 lm with CV driver for proper driving of LEDs constructed from aluminium die cast (powder coated). Tempered Frosted Step Glass with IP Protection of IP66.The LEDs used in the product shall be of reputed make like Citizen Japan / Nichia Japan/Osram/Cree/Everlight with minimum LED efficacy of 140lm/W LED with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 3000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 3kV with Colour changing solution in RGB.Fixture have beam angle of 40 degree.Including all accessories.(Wipro Cat. No: LF27-601-040-CC-XX/ Equivalent/Philips Color Kinetics Colorreach Power Core Gen2/Trilux/Ligman)( Gumbad of Sarovar Temple)
Driver ( Wipro Cat. Code :ELG-240-48 / Equivalent in Philips /Trilux)
DMX controller ( Wipro Cat. Code :LG70-360-3M-48V / Equivalent in Philips /Trilux)
T connector 4C ( Wipro Cat. Code :C-T-4C-IP67 / Equivalent in Philips /Trilux)
S-Connector ( Wipro Cat. Code :C-S-4C-IP67 / Equivalent in Philips /Trilux)
Supply, carriage and erection of PVC Copper cables 3Core / 4Core flexible 1100V grade FR PVC insulated and PVC sheathed as per IS694-1990. The cable is to be laid in existing pipe / duct fixed with suitable clamps as per site requirements including their cost. The work should be completed as per satisfaction of Engineer-in-charge / Architect. (Finolex / Havell's / RR / Polycab make only)
2.5Sqmm 3Core
2.5Sqmm 4Core
4Sqmm 4Core
Supply, Carriage and laying of Power Copper Cables, Solid Copper Conductor Upto 6 Sqmm And Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured, Extruded PVC Type ST2 Sheathed, 650/1100 V Grade As Per IS 7098 (Part 1) 1988. The cable is to be laid in existing trench / pipe / duct fixed with suitable clamps as per site requirements including their cost. The work should be completed as per satisfaction of Engineer-in-charge / Architect. (Finolex / Havell's / RR / Polycab make only)
4Sqmm 3Core
6Sqmm 4Core
Supply, Carriage and erection of thermoplastic cable junction boxes IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry) of various sizes for termination of cables. The box is to be embedded in the Cement Concrete Plateform / on wall / ceiling as per site requirement. The job includes cost of junction box with petty material required to fix the box excluding cost of cement concrete. The work should be completed as per satisfaction of Engineer-in-charge / Architect. (Hensel / Diplast or make similar to Hensel)
Junction Box of size 130x180x77mm suitable for 4-10 sq.mm
Junction Box of size 104x104x70mm suitable for 1.5-4sqmm
NOTE: The Electrification job includes cost of petty material required to fix the fitting as per the instruction of Engineer-in-charge. The work should be completed as per satisfaction of Engineer-in-charge / Architect. (Work on All heights & Levels)
CIVIL WORKS
Drilling / Cutting hole by mechnical means upto 23cm square in RCC Floor / Roofs for making provision for Lighting Fixtures in RCC Slab and making good the same & finishing according to existing finish where required complete as per directions of Engineer-In-Charge.
Floor cutting with cutter (Mechnical Means) for taking pipe / cable to corridor from electric trench including relaying the same with new matching stone over cement mortar and required base to match existing floor, pointing work etc complete to the satisfaction of EIC.
Wall cutting with cutter (Mechnical Means) for laying pipe after removing stone and reinstallation of stone with new matching stone fixed with cement slurry over cement mortar and required base to match existing floor, pointing work etc complete to the satisfaction of EIC.
Covering of PVC conduit 25mm / 32mm dia with cement concrete 1:2:4 all around pipe laid in floor / ground including cutting floor / excavation work as per requirement complete in all respects to the satisfaction of EIC.
Bidder Name
Amount
Krishna Construction Co
Highlight Associates and Contractors
MAHESH KUMAR SINGLA CONTRACTOR
ESS ESS ENGINEERS
MAHESH KUMAR SINGLA CONTRACTOR
ESS ESS ENGINEERS
Krishna Construction Co
Krishna Construction Co
MAHESH KUMAR SINGLA CONTRACTOR
Highlight Associates and Contractors
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .