Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC VILL SANTINAGAR WARD NO 1 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹3.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 Cr+₹3,955.50 (0.01%)Rejected-AOC | ₹3.6 Cr+₹3,955.50 (0.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.6 Cr+₹18,955.50 (0.05%)Rejected-AOC | ₹3.6 Cr+₹18,955.50 (0.05%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
28 Feb 2020, 4:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of Road from Kokrajhar Main Bazar to Law College along with drain, Cycling Track, etc. under City Infrastructure Development Fund for the year 2019-20.
2020_BTC_16430_1
27/KOJ/IFB/2016-17/Pt-I/17
Open Tender
Electrical Works
Item Rate
365 days
Kajalgaon
Refer to SBD
6 documents required · 6 mandatory
₹10,800
Principal Secretary, BTC, Kokrajhar
₹7.2 L
Yes
5 Jun 2020
13 Feb 2020
29 Feb 2020
13 Feb 2020
28 Feb 2020
13 Feb 2020
13 Feb 2020 - 28 Feb 2020
Amount
(A) Non Schedule Items: Annex-1: Supplying with installation, testing and commissioning of Solar Panel 300 w/24 Volt (ISI marked or as approved by the department) in proper position and jamp with required nuts and bolts clamps etc. as required and as directed as specified and by the Department.
Annex-2: Supplying with installation, testing and commissioning of Central Inverter 100 KVA/360 Volts (ISI marked or as approved by the department) in proper position and jamp with required nuts and bolts clamps etc. as required and as directed as specified and by the Department.
Annex-3: Supplying with installation, testing and commissioning of Central Inverter 100 KNVA/96 Volt 50Hz Combiner and Junction Box Solar current distributor (ISI marked or as approved by the department) in proper position and jamp with required nuts and bolts clamps etc. as required and as directed as specified and by the Department.
Annex-4: Supplying with installation, testing of Solar panel structure on GI pipe (ISI marked or as approved by the department) frame of required size clamping with nuts and bolts, CC foundation etc. as required and as directed as specified and by the Department.
Annex-5: Supplying with installation, testing of Solar panel Battery150 Ah/12 Volt of branded company with battery racks (ISI marked or as approved by the department) as required etc. as required and as directed as specified and by the Department.
Annex-6: Constructure of Solar Inverter and Batteries house (Assam Type) plinth area size (9.09 x 7.58) Mtr. = 68.90 Sq. mtr. (Rate as per PWD Building Schedule 2013-2014)
(B) Schedule Items: 32.12: Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm. 8 x 2.5 sq. mm. 2 x 10 sq mm. 3 x 10 sq mm. 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ HAvells/RPG/ CCI/ Polycab/ Gloster/ Finolex make). 32.12 4 Core, 2XWY 2XFY 32.12.4.3 10.00 Sq. mm.4 Core armoured
32.12.4.4 16.00 Sq. mm.4 Core armoured
32.12.4.7 50.00 Sq. mm.4 Core U.G. armoured cable
32.12.4.10 120.00 Sq. mm.4 Core U.G. armoured cable
16.44: Supplying with fitting and fixing Four Pole 415V Front handle operated on Land Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.44.1 C&S, Havells, Indo Asian, HPL, GECO make 16.44.1.6 400A
15.21: Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.21.1. ABB, Schneider MG, legrand, Hager make) 15.21.1.3. 12 way TPN (4+36) single door
16.42: Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.42.1. 35/36 KA 415V 50 Hz 4P MCCB (C&S, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.) 16.4213 315A
1.10: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.10.4. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in flat 32 mm ISI marked casing 'n' capping| system.
1.10.5. With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm, cable in flat 32 mm ISI marked casing 'n' capping| system.
22.4: Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 2.00 Metres length corrosion free Single pipe technology- Copper CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV) including excavation of earth pit and const. brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
22.6: Supply, installation & commissioning of Advanced Lightning protection system by using High pulse Voltage ESE Lightning conductor with Optimized Pulse Rod (ABB| or equivalent make) as specified and directed by the deptt| (as per NFC 17 - 102 STANDARD & IEC Std 60 - 111989)
(C) Baterry and Inverter Room. 1.1: Wiring for light/ fan/ call bell point with 2x1.5 sq mm |P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.1. Short point up to 3.00 metre. length.
1.1.2. Medium point up to 6.00 metre. Length.
1.1.3. Long point up to 10.00 metre. Length.
1.2: Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright| annealed electrolytic copper conductor for voltage grade up| to 1100 volts (Finolex /RR Kabel Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm, cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.2. Medium point up to 6.00 metre. Length.
1.3: Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16| Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover) earth continuity with 2.5 sq.mm cable to the 3rd pin of the socket as required complete. 1.3.3. Long point up to 10.00 metre. Length.
1.8: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100|| volts (Finolex /RR Kabel Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ |MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
11.8.2. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system.
1.10: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR| conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.10.4. With 4 x 10 sq.mm. + earth continuity with 2x6 sq. mm. cable in flat 32 mm ISI marked casing 'n' capping system.
11.11: Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required.
14.1: Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 14.1.1. 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)
15.4: Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts asreqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.4.1. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 15.4.1.1. 4 way SPN double door
15.7: Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.7.1. ABB, Schneider MG, legrand, Hager make) 15.7.1.1. 4 way TPN (4+12) Single Door
16.1: Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1. B Series (Schneider MG, legrand, Hager make) 16.1.1.1.6 to 32A
16.3: Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1. B Series (Schneider MG, legrand, Hager make) 16.3.1.2. 40A
16.4: Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.4.1. B Series (Schneider MG, legrand, Hager make) 16.4.1.3.63A
22.7: Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.1. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.1. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12: Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. Supplying &
22.16: laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
29.1: Supplying with installation testing and commissioning of Hi-wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt. )up to 5 m between the room unit and out door unit as directed by the department 29.1.3. 2 Ton capacity 29.1.3.3.
30.11: Supplying with fitting and fixing Single Phase D.O.L Starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 30.11.2. Overload Relay Range 6.0-9.3 Amps for 3.7 KW
31.1: Supplying with fitting and fixing Voltage stabilizer of the |following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 31.1.6.3.0 KVA Automatic Input 90-280V Out put 200-240 V
32.1: Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 32.1.4. 4 Core A2XWY A2XFY 32.1.4.4. 16.00 Sq. mm.4 Core armoured U.G. cable
ECBC. 3.28: Supplying installation testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/ceiling including connection with 1.5 sq. mm PVC insulated S.C. Copper conductor as required and as directed by department ECBC.3.28.1. LED Lamp indoor application operating voltage 90V-250V, 12V DCI Model GN 1/1-2 or equivelent LED Lamp with main input (make Philips, Bajaj. Schneider, Havells)
ECBC. 3.18: Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED round fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. ECBC. 3.18.2. LED Round Light,6W
M/S J.B. ENTERPRISE
Manasa Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .