GEMC-511687781338513
Awarded to THE SERVICE POINT
₹1.7 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPL ECG MACHINE 9108 | 9108 | - | 2 NOS | ₹82,900 | 165,800 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 LQualified Make: BPL
Model: 9108 D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: 9108 | L1 | Qualified | |
| 2 | L2₹1.8 L+₹11,700 (7.06%)Qualified Make: BPL
Model: 9108 00 PC GROUP AKHARI BYPASS TRIMUHANI CHUNAR ROAD VARANASI VARANASI VARANASI UTTAR PRADESH 221011 | VARANASI | UTTAR PRADESH | 221011 | Make: BPL
Model: 9108 | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Sept 2018, 1:00 pmClosed
electrocardiography ekg/ecg units ( PAC Only ) Experience with Gov. Required 3 Year (s) Electrocardiography Ekg/ecg Units ( 2 ) ( Under PAC ) Make bpl Model 9108 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport * Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes * Heart rate trend display of at least previous 24 hours yes * In built Software and/or standard of communication yes * Heat Dissipiation: yes * 1/4 Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan User interface manual * Noise Lavel (dba) - * Electrical protection provided by fuses in both live and neutral supply lines yes * Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * Arrhythmia detection facility required; minimum gradation of 1 bpm yes * Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high yes * 2/4 heart rate Operates from mains voltage or from internal rechargeable battery Power consumption - * weight - * Power cable length (meter) 3 METER OR MORE * Display must allow easy viewing in all ambient light levels yes * Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes * STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) US FDA approved product
ISO 13485 Certificate For Quality Standard
Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs)
C E Approved product * MISCLANEOUS Warranty (years) 3 3
5 (or higher) power input and frequency 220 To 240V
50 Hz AC * Certificate of Calibration and Inspection to be provided YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Akashdeep Kumar 110093
Rajiv Gandhi Super Specialty Hospital
Tahirpur 2 15 3/4
606173
GEM/2018/B/86082
GeM Contract
electrocardiography ekg/ecg units
GeM Contract
15 days
Delhi; North East Delhi
PRODUCT
Awarded to THE SERVICE POINT
₹1.7 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPL ECG MACHINE 9108 | 9108 | - | 2 NOS | ₹82,900 | 165,800 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units ( PAC Only ) Experience with Gov. Required 3 Year (s) Electrocardiography Ekg/ecg Units ( 2 ) ( Under PAC ) Make bpl Model 9108 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport * Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes * Heart rate trend display of at least previous 24 hours yes * In built Software and/or standard of communication yes * Heat Dissipiation: yes * 1/4 Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan User interface manual * Noise Lavel (dba) - * Electrical protection provided by fuses in both live and neutral supply lines yes * Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * Arrhythmia detection facility required; minimum gradation of 1 bpm yes * Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high yes * 2/4 heart rate Operates from mains voltage or from internal rechargeable battery Power consumption - * weight - * Power cable length (meter) 3 METER OR MORE * Display must allow easy viewing in all ambient light levels yes * Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes * STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) US FDA approved product | - | - | - |
| ISO 13485 Certificate For Quality Standard | - | - | - |
| Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs) | - | - | - |
| C E Approved product * MISCLANEOUS Warranty (years) 3 3 | - | - | - |
| 5 (or higher) power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC * Certificate of Calibration and Inspection to be provided YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Akashdeep Kumar 110093 | - | - | - |
| Rajiv Gandhi Super Specialty Hospital | - | - | - |
| Tahirpur 2 15 3/4 | - | - | - |
Exempted
12 Nov 2018
13 Sept 2018
contract_GEMC-511687781338513.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_606173.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .