| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC Awarded being L1. | |
| 2 | L2₹6.6 L+₹68,150 (11.5%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹8.9 L+₹3.0 L (50.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINTENANCE OF INDUSTRIAL RO PLANTS AND SAND FILTRATION TANKS, WATER PUMPS AND MOTORS AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K).
2024_MES_661562_1
CA NO. AGE (I) CIF (K) - 27/2024-25
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS.
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹20,000
Yes
25 Oct 2024
22 Jun 2024
5 Sept 2024
22 Jun 2024
3 Sept 2024
6 Jul 2024
Amount
Material and labour for servicing to RO Plant of capacity 3000 Litres/hours including chemical cleaning by skilled person of Indian ion company, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for servicing to RO Plant of capacity 500 Litres/hours including chemical cleaning by skilled person of Thermax company, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Hydraulic membranes top quality recommended by Indian ion company suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I)
Supply and fixing in replacement Hydraulic membranes top quality recommended by Thermax company suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make -Thermax or equivalent as approved by AGE (I).
Supply and laying in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement UV Ballast and fuse etc. complete suitable for 3000 litres per hour RO Plant , complete all as specified as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Ballast and fuse etc. complete suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Candle 20 inch long suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Candle 20 inch long suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make -Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Hose pipe 20 mm suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement Hose pipe 20 mm suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I)
Supply and fixing in replacement Rotor Meter suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I)
Supply and fixing in replacement Rotor Meter suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Pressure Meter suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Pressure Meter suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Relay for automatic Panel suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement Relay for automatic Panel suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 5.5 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 3000 litres per hour RO plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ION or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 2.5 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 500 litres per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Dismantling and replacement of existing burnt winding of water pump 2 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 3000 litres per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Indian ION or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 1 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 500 Ltrs per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Taking down old unserviceable PVC pipe 32mm bore and supply and fixing new PVC pipe 32mm bore complete with all fitings, complete all as specified as directed by the Engineer-in-Charge.
Supply and fixing in replacement globe or gate valves, 32mm bore brass body head, screwed both ends (as per sample) for stainless steel pipe, complete all as specified and directed by the Engineer -in - Charge. Make :- Bir/Venus/Leader/Kirloskar
Supply and fixing in replacement gun metal, globe or gate valves, 50 mm bore with iron wheel head, screw both ends for iron pipe and fixed , complete all as specified and directed by the Engineer -in - Charge. Make :- Bir/Venus/Leader/Kirloskar
Material and labour for servicing of dosing pump 0.5 HP capacity and repalcement of PVC pipe complete as specified and as directed by the Engineer -in - Charge.
Supply only Cartridge 30 inches long of RO Plant 3000 Litres /hours, complete all as specified as directed by the Engineer-in-Charge. Make - Indian Ion or equivalent as approved by AGE (I).
Supply only dosing Chemical anti-scalant as per recommended by indian ion company, complete all as specified as directed by the Engineer-in-Charge.
Supply and fixing in replacement Media carbon (coconut shell coal) suitable for sand filtration plant of capacity 10000 Glans, complete as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement Media complete (stone,sand and pebbles) suitable for sand filtration plant, complete as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement PVC nozzels suitable for sand filtration plant of capacity 10000 Glans, complete all as specified and directed by the Engineer -in- Charge.
HEATING PLANTS AND WATER PUMPS
Material and labour for dismanteling Hot air plant /wall mounted heater , transporting to work shop for repair/ servicing such as Calibration and complete repair of Hot air plant of any capacity on work bench pressure supply of Hot air as standard procedure any spares require for repair such as washers, for speed adjustment ,split cotter pin etc as deemed to be inclusive in the quoted rates.
Material and labour for dismanteling to fuel injector pump, transporting to work shop for repair/ servicing such as Calibration and complete repair of fuel injecton pump of Hot air plant of any capacity on work bench pressure supply of fuel as standard procedure any spares require for repair such as washers, for speed adjustment ,split cotter pin etc as deemed to be inclusive in the quoted rates.
Disconnecting existing defective electric motor of any make 20/15 HP from electric mains isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, decouple from pump, opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site or transporting to workshop and back, re-assembling the motor after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of defecting parts shall be measured and paid separately as S&F here after. (b) In case of major repairs not possible at site, the motor shall be shifted to contractor’s workshop, and cost of shifting to workshop and back to site included in the rates
All as per item No 35 above but capacity 2.0 to 5.0 HP
Taking out old unserviceable/burnt copper winding of motors capacity 20/15 HP (defective motor taken out in item No. 30 above) and material and labour for rewinding of elect motor of capacity 20/15 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge all as specified and as directed.
All as per item No.37 above but capacity 2.0 to 5.0 HP
M&L for replacement of coupling suitable for pump set 20 HP capacity centrifugal pump all as specified and directed as per site requirement.
Taking out unserviceable terminal plate with connector and outer cover of elect motor of any make, type 20 HP capacity and supply & connect, testing terminal plate with connector same as per existing complete all as specified and as directed Engr-in-Charge.
All as per item No.40 above but capacity 2.0 to 5 HP
M/L or replacement of Ball bearing of the electric motor 20/15 HP opened in item No 40 here in before complete all as directed. Make: SKF/TATA/NBC.
All as per item No.42 above but capacity 2.0 to 5 HP
Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out from well the submersible pump set including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carry out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down in well, including column pipe of any dia, 10 ft long upto 20 Nos, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning all as specified and as directed. (The replacement of parts shall be measured and paid separately)
Taking out old unserviceable/burnt winding from the submersible 3 phase motors 5 HP and M&L for rewinding the same with insulated winding wire as per existing gauge as approved by E-in Charge and testing after repair all as specified and as directed.
All as per Ser Item No 45 but motor 10 HP
All as per Ser Item No 45 but motor 15 HP
All as per Ser Item No 45 but motor 1.0 to 1.5 HP
M & L for replacement of unserviceable/ defective Gun metal bush of submersible pump of any make and capacity 5 HP pump motor after inspection by Engineer-in-Charge all as specified and as directed.
All as per Ser Item No 49 but motor 10 HP
All as per Ser Item No 49 but motor 15 HP
M & L for replacement of unserviceable/ defective PVC bush of submersible pump of any make and capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge all as specified and as directed.
M & L for replacement of unserviceable/ defective PVC impeler of submersible pump of any make and capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge all as specified and as directed.
M & L for replacement of unserviceable/ defective Gun metal impelar of submersible pump of any make and capacity 10 HP after inspection by Engineer-in-Charge all as specified and as directed.
All as per Ser Item No 54 but 15 HP
All as per Ser Item No 54 but 5 HP
Material and labour for dismanteling to fuel injector pump, transporting to work shop for repair/ servicing such as Calibration and complete repair of fuel injecton pump of Hot air plant of any capacity on work bench pressure supply of fuel as standard procedure any spares require for repair such as washers, for speed adjustment ,split cotter pin etc as deemed to be inclusive in the quoted rates.
Supply instalation testing and commissing star delta starter three phase submersible pump controllers (with single phase preventer) with enclouser for 15/17.5 hp pump .Modle no MU-G15 FASD(WITH WIDEBAND COIL)Complete all as spd and as directed.Make:-l&T
Supply instalation testing and commissing star delta starter three phase submersible pump controllers (with single phase preventer) with enclouser for 20/15 hp pump .Modle no MU-G20 FASD(WITH WIDEBAND COIL)Complete all as spd and as directed.Make:-l&T
Supply instalation testing and commissing star delta starter three phase submersible pump controllers (with single phase preventer) with enclouser for 5/10 hp pump .Modle no MU-G10 FASD(WITH WIDEBAND COIL)Complete all as spd and as directed.Make:-l&T
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution 100 Amp capacity .cat no IHCNFOO100 of Havell’s or equlant of /L&T/ Siemens
Material and labour for dismanteling to fuel injector pump, transporting to work shop for repair such as Calibration and complete repair of fuel injecton pump of Hot water plant 1000 ltrscapacity per hour on work bench pressure supply of fuel as standard procedure any spares require for repair such as washers, for speed adjustment ,split cotter pin etc as deemed to be inclusive in the quoted rates.
All as per Ser Item No 62 but replacement of nozle tip
All as per Ser Item No 62 but replacement of poto sensor
All as per Ser Item No 62 but replacement of poto ignetion transformer
All as per Ser Item No 62 but replacement of burner gasket
All as per Ser Item No 62 but replacement of electromegnet rod
All as per Ser Item No 62 but replacement of auto thermocut
All as per Ser Item No 62 but replacement of relay box
Note :- An amount of Rs. 19,796.00.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S Ghulam Mohammad Shalla (BID ID -3060246)
M/S RATHER STEEL WORKS (BID ID -3078515)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .