Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.1 L+₹2.4 L (9.30%)Rejected-Finance MALLICK JAYANTI BAGAN KUMAR BAGAN JHAPPUKUR POST SAHAGANJ DIST HOOGHLY HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance Highest
Amount Quoted | |
| 3 | L3₹28.4 L+₹2.8 L (10.8%)Rejected-Finance P O VILL SUGANDHA DIST HOOGHLY WEST BENGAL | SUGANDHA | HOOGHLY | WEST BENGAL | 712102 | L3 | Rejected-Finance Highest
Amount Quoted |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
27 Oct 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division
Emergent_Electrical_Installation_work_arrangement_of_Air_conditioning_and_UPS_Power_Back_up_in_respect_of_preparation_of_proposed_HDU_CCU_unit_at_ground_floor_of_CMDA_building_of_Uttarpara_State_General_Hospital_Uttarpara_in_the_District_of_Hooghly
2021_WBPWD_345852_1
WBPWD/EE/ HED / NIeQ-16/ 2021-22 (2nd Call)
Open Tender
Electrical Work/ Equipment
Item Wise
25 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
3 Nov 2021
28 Sept 2021
30 Oct 2021
28 Sept 2021
27 Oct 2021
28 Sept 2021
120 days
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch of grey/black colour (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
8 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switchof grey/black colour (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C) as per GS.
On Board [ 3 (i) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm) + 1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ]
4x(10 sqmm)+2x (6 sqmm) [ 1(d1) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
e) 10 sq mm [9(iv) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
240 x 200 x 65 [11(d)/E-4 ,12(d)/E-5]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )
8 Way Make - Legrand, Enclosure-607717/Schneider,Enclosure-A9HTND08/Crabtree, Enclosure- (DCDKTHODCW08) or equivalent cat of LT/Siemens as approved E.I.C] [ 14 / D- 10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing 415V, FP Changeover switch with Sheet Steelenclosure on angle iron frame on wall with nuts bolts etc.
63 A [Make - Havells/HPL/LT as approved by E.I.C] [2(b)/D-1]
Supplying and fixing 415V TPN SFU with sheet steel enclosure of following rating on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.( Make - L&T /Siemens/ABB)
200 A TPN SFU [4(a)/D-3]
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc(Make-L&T /HPL/Havells)
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Havells as approved E.I.C]
3.5 Core 95 Sq. mm
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. As necy., mending good damages and painting.
from 35 to 95 Sq. mm [ 2(e)/ F- 1 ]
Laying of cable in underground trench as per GS for the following numbers of Cables.
Above 35 and upto 185 Sq. mm [ 1(b)/ F- 2 ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
Above 35 to 95 Sq. mm [ 5(ii)/ F- 3 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
3.5 Core 95 Sq. mm [7(d)/F4 & 8(b- xviii) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
50 mm dia [11(d)/F-6]
Supply & Fixing 240 V, 4 nos. 6/16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch of grey/black colour (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[15/E-19]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket of grey/black colour (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [9(a)/E-18]
Supply & Fixing 240 V 16 A, 3 pin Modular type plug socket of grey/black colour (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [9(b)/E-18]
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17 / E-19]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [ 5(b) / E-17]
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25/32 A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 25/32 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC.
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supply & Fixing 240 V, 32 A, Modular type AC starter (Havells cat no.-AH00323204 or equivalent Brand approved by EIC) in existing 2 way SS encloser as per direction of EIC.
Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A, 4-Pole-3P+N+E Metal Industrial Plug socket & 63A Industrial top(Legrand Cat no.-5078 64 or equivalent model of Siemens/ABB) incl. S&F 63 A FP MCB(Legrand DX-series or equivalent model of Siemens/ABB) of breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary connection.
Supplying & Fixing Industrial Plug & Socket board with 240 V, 32A, SPN & Earth Metal Industrial Plug socket (L&T cat no.-MPS332S or equivalent) & 32A Industrial top(L&T cat no.-MPS332p or equivalent) in SS enclosure fixed on wall and nececessary interconection incl. S&F 175x100x65mm Sheet metal Inspection Box[11(c )/E-4] and 3mm thick Bakelite top cover(13(c )/E-5] .
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supply and fixing 14 W LED bulb(Bajaj/CG/Philips/wipro) on existing batten holder
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [ 14d/C-2 ]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ]
Supply & fixing 450mm sweep wall bracket fan (high speed) with metal body & blades (Orient - Wall-II Tornado, or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.
Dismantling the existing damaged defective unuseable electrical Installation materials.
S & F of porcelain kit kat rewireable type fuse unit (Beat quality approved make) and base complete on Hard Wood Board size 600 x 300 x 25 mm fixed on wall with anchor fastener bolts.
SITC of 20 KVA/ 18 KW IGBT based UPS with three phase in /three phase out with battery backup for one hour (minimum 31200 VAH Flame retardent battery) as per details annexure enclosed.(with 2 years warrenty incl. Battery). [Factory testing is essential before despatch]. [Make : APC / Numeric / Emerson /AVO as approved by E.I.C]
Topology, IGBT BASED DSP CONTROLED
Rating of UPS(KVA/KW): 20 KVA / 18 KW
Input Frequency: 40 to 70 Hz
TVSS: Inbuilt TVSS should be present as per ANSI/UL 1449 Third Edition
Input PF: .99 with IGBT Rectifire
Isolation Transformer: Delta to Star Inbuilt Isolation Transformer with 1:1 ratio at UPS Input to be provided . No external/Step up Transformer will be accepted
Back feed Protection: UPS should have back feed protection
DC Ripple: Residual ripple Voltage should be <1%
Charging: Autometic float cum Boots Charging Capability with setteble flote & boost charging voltages and current levels and boots charger timer
Input current Distortion: THDi<=3%
Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3%
Output Frequency: 50 Hz +/- 0.1%
Output Power Factor: 0.9
Crest Factor: 3:1
THDu: < 1% (linear load), < 5%(non linear load)
Waveform: Pure Sine Wave
Birdge: Microprocessor based and IGBT Technology
Overload: 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minutes.
Static By Pass: 100 % rated static switches with fuse protection overload on Bypass: 100% for 10 ms
Overall Efficiency: 93%
Battary Cabine: With power coated MS angle with MS sheet suiteble dimention and gadge, well air ventilation to ensure the battery optimum life cycle.Useing Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress.
Battery : 12 V, Mono Block batteries. SMF VRLA
DC Bus : Minimum 384V or above, 60 mim back up required (Minimum 32770 VAH) Battery. Battery Make: Exide/Amar Raja(Quanta)
Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery
Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
Metering: Graphical LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch
Termination: Input, Battery, Output & Bypass
Enclosure: IP 20
Operating Temp: 0 to 40 Deg C
Humidity: Upto 95% Rh (non-condensing)
Cooling: Forced Air
Noise: < 55 dB
Cold Start : Provided
Parallel Redundant facitities should be present for each unit with Accessories
Communication: RS 232, RS 485, Dual input Kit,
Monitoring Software: UPS Monitoring Software on Windows XP Platform
Certification : ISO 9001: 2008, ISO 14001: 2004, ISO 18001, RoHS and OHSAS 18001
CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
Supply of 3.0 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32. (Make- O-General Model-ASGA36FUTC or equvalent model of Hitachi/Daikin as per approved by EIC). (4 nos. for HDU-I & 6 nos. for HDU-II)
Supply of 3 Star rated 2.0 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32. (Make- Hitachi, Model- Takeshi-3100f or equvalent model of O-General/Daikin or other equivalent make as per approved by EIC)
Supply of 3 Star rated 1.0 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32. (Make- Hitachi Model- ZUNOH 3100f or equvalent model of O-General/ Daikin or other equivalent make as per approved by EIC)
Installation, testing & commissioning of the above-said split AC incl. supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C.
Supply, installation & commissioning Copper Refrigeration pipe line for liquid and suction line with supports & brackets for hiwall split AC.
a) Liquid Line (3/8" OD HD Copper Pipe with 0.6mm thick)
b) Suction line (5/8" OD HD Copper Pipe with 0.7mm thick)
Supply & Fixing Pipe Insulation in suction & liquid line with 9mm nitrile rubber tube for hiwall split AC.
Liquid Line
Suction Line
S & F of Control copper Cabling from ODU Unit to IDU unit of hiwall Split AC.
3 Core 2.5 sq. mm. Communication Cable
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
25 mm dia
Supply & charging Refrigerant-R410A
Supply & Laying Extra Add-on items- 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 3 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for A.C. Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C.
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar (4:2:1) as per GS [ 14 / J2 ]
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works as per GS [ 9 / J-1 ]
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work as per GS [ 11(a) / J-1 ]
Making soldered joints between conductors, conductors and air terminals by 7/10 stranded GI (Hot Dip) wire or 20 mm x 3 mm thick GI (Hot Dip) wire / strip incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint [12a / J-2 ]
Making soldered joints between conductors and down pipes/ other metallic objects by 7/10 stranded GI (Hot Dip) wire including supply of necessary 4 SWG or 20 mm x 3 mm thick GI (Hot Dip) wire / strip incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint [12b / J-2 ]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required as per GS [ 13 / J-2 ]
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: as per GS
Length Upto 0.5 Mtr [ 4(a) / J1 ]
Length above 0.5 Mtr [ 4 (b) / J1 ]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of overhead reservoir (vertical run) as per GS [ 7 / J1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Supply and laying 32 mm x 6 mm thick GI (Hot Dip) strips/tape directly in ground level from earth electrode and interconnecting all earth Electrodes surrounding lower portion of the building to form a grid structure as per direction of E.I.C
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-6 SWG [5(a)(ii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
TERMS AND CONDITION 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES.
Add GST @12% except item no.-15:- Rs.
Add LWC @1% except item no.- 14,31,42,43 & 44 :- Rs.
B.S.M ELECTRICAL
UNION ENGINEERING COMPANY
stage.html
html • 0.05 MB
technical_663571.pdf
PDF • 0.62 MB
techsummary_663571.pdf
PDF • 0.78 MB
finance_663571.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_663571.pdf
PDF • 0.48 MB
16_2ND.pdf
PDF • 0.12 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .