Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.5 L+₹9,318 (0.57%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹22.8 L+₹6.4 L (38.9%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹27.9 L+₹11.5 L (70.3%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical No, Adverse remark found in WLR QE Dec 2025 of HQ CEEC. Hence, rejected |
| Sl No | Description | Qty | Unit | Shiv Enterprises L2 | P S TRADERS L1 | RUCHIKA ENGG.WORKS L4 | SNOWY ENGINEERING INC L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting electrical connections of package type AC plant for servicing of capacity 11 TR including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing as required and refixing the same in existing position complete all as specified and as directed . | 4 | Each Job | 2,500 ₹10,000 | 500 ₹2,000 Lowest | 5,000 ₹20,000 | 1,500 ₹6,000 |
| 2.00 | M&L for rectifying electrical wiring fault of package type AC plant of capacity 11 TR and make them functional and also carry out the required repair complete all as specified and as directed. | 6 | Each Job | 1,500 ₹9,000 | 500 ₹3,000 Lowest | 1,000 ₹6,000 | 900 ₹5,400 |
| 3.00 | M&L for Disconnecting from mains/ taking out existing unserviceable/defective 3 phase, scroll compressor of Package type AC Plant of capacity 5.5 TR and supply and fixing new scroll compressor including making connections of suction and discharge copper pipe by brazing, pressure testing by Nitrogen gas, rectification of leakage if any, vacuumising and initial charging of refrigerant gas R-22, commissioning & testing for satisfactory working complete all as specified and directed by Engineer-in-Charge. (Make:- Emerson Model No. ZR72KC-TFD-522 or equivalent model of make Voltas/ Blue Star/ Tecumseh.)
(Note :- The rates quoted by the contractor shall deemed to be included the cost of initial charging of Refrigerant gas R-22.) | 4 | Each Job | 18,000 ₹72,000 Lowest | 35,000 ₹1,40,000 | 48,000 ₹1,92,000 | 27,600 ₹1,10,400 |
| 4.00 | S&F in repair of liquid line drier filter of capacity 5.5 TR complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 4 | Each | 1,000 ₹4,000 Lowest | 1,100 ₹4,400 | 1,000 ₹4,000 Lowest | 1,750 ₹7,000 |
| 5.00 | S&F in repair of condenser fan motor of capacity As per existing motor complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 3 | Each Job | 2,500 ₹7,500 | 2,000 ₹6,000 Lowest | 4,000 ₹12,000 | 4,850 ₹14,550 |
| 6.00 | Supply and fix in repair Condenser fan blade made out of Aluminium suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 3 | Set | 300 ₹900 Lowest | 300 ₹900 Lowest | 3,500 ₹10,500 | 950 ₹2,850 |
| 7.00 | Supply and fix in repair Blower fan motor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 3 | Each | 1,000 ₹3,000 Lowest | 2,000 ₹6,000 | 6,000 ₹18,000 | 2,850 ₹8,550 |
| 8.00 | Supply and fix in repair Low pressure cut off switch/ sensor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 5 | Each | 800 ₹4,000 | 700 ₹3,500 Lowest | 1,500 ₹7,500 | 900 ₹4,500 |
| 9.00 | Supply and fix in repair High pressure cut off switch/ sensor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 5 | Each | 800 ₹4,000 | 700 ₹3,500 Lowest | 1,500 ₹7,500 | 900 ₹4,500 |
| 10.00 | Supply and fixing in repair copper tube 7/8" dia | 25 | RM | 300 ₹7,500 Lowest | 500 ₹12,500 | 1,000 ₹25,000 | 550 ₹13,750 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
20 Apr 2026, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE OF 3 X 11 TR AC PLANT AT HQTG EME COLD STORAGE ROOM INSTALLED AT 226 ASC SUPPLY DEPOT AND AMBIATORS INSTALLED AT 505 ABW UNDER GE (U) PM DELHI CANTT10
2026_MES_758550_1
GE(U)/PM/D-82/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
Delhi Cantt
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹56,000
Yes
3 Jun 2026
30 Mar 2026
23 Apr 2026
30 Mar 2026
20 Apr 2026
13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Disconnecting electrical connections of package type AC plant for servicing of capacity 11 TR including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing as required and refixing the same in existing position complete all as specified and as directed . | 4 | Each Job | - | - |
| - | M&L for rectifying electrical wiring fault of package type AC plant of capacity 11 TR and make them functional and also carry out the required repair complete all as specified and as directed. | - | Each Job | - | - |
| - | M&L for Disconnecting from mains/ taking out existing unserviceable/defective 3 phase, scroll compressor of Package type AC Plant of capacity 5.5 TR and supply and fixing new scroll compressor including making connections of suction and discharge copper pipe by brazing, pressure testing by Nitrogen gas, rectification of leakage if any, vacuumising and initial charging of refrigerant gas R-22, commissioning & testing for satisfactory working complete all as specified and directed by Engineer-in-Charge. (Make:- Emerson Model No. ZR72KC-TFD-522 or equivalent model of make Voltas/ Blue Star/ Tecumseh.)
(Note :- The rates quoted by the contractor shall deemed to be included the cost of initial charging of Refrigerant gas R-22.) | 4 | Each Job | - | - |
| - | S&F in repair of liquid line drier filter of capacity 5.5 TR complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 4 | Each | - | - |
| - | S&F in repair of condenser fan motor of capacity As per existing motor complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 3 | Each Job | - | - |
| - | Supply and fix in repair Condenser fan blade made out of Aluminium suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 3 | Set | - | - |
| - | Supply and fix in repair Blower fan motor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 3 | Each | - | - |
| - | Supply and fix in repair Low pressure cut off switch/ sensor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 5 | Each | - | - |
| - | Supply and fix in repair High pressure cut off switch/ sensor suitable for 3 x 11 TR package type AC Plant all as specified and as directed by Engr-in-Charge | 5 | Each | - | - |
| - | Supply and fixing in repair copper tube 7/8" dia | 25 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
D82TENDER.pdf
Tender Documents • 1.21 MB
D82SCHOFCREDIT.pdf
Additional Documents • 0.80 MB
BOQ_849618.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .