Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC LOWEST AND RESONABLE | |
| 2 | L2₹33.7 L+₹95,202.50 (2.91%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹41.2 L+₹8.4 L (25.7%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹45.2 L+₹12.4 L (38.0%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹45.9 L+₹13.2 L (40.3%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KOLKATA
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
REPAIR / MAINT OF HT NETWORK SYSTEM AND ITS ALLIED WORKS UNDER GE(FW) KOLKATA
2022_MES_516428_1
8185/E-03/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW)KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE(FW)KOLKATA
₹98,000
17 Jun 2022
4 Apr 2022
6 May 2022
4 Apr 2022
3 May 2022
19 Apr 2022
4 Apr 2022 - 15 Apr 2022
90 days
Amount
Disconnecting & Taking down / out unserviceable HT XLPE cable 6.6 KV of size 70 Sqmm to 300 Sqmm 3 Core of any description from trenches, Floors, walls, GI Pipes Etc, seggrating serviceable cables, pipes, bricks etc including keep in safe custody for re-use and unserviceable cable removing to and depositing at AGE E/M Store Yard complete all as specified and directed. Note:- (i) Any damage / punctured into HT cable the contractor will be responsible. (ii) Before laying meggaring the complete cable in presence of ENgineer-in-Charge. (iii) Damege / Fault detection of HT cable will be responsibility of the contractor and new same size cable will be provided by contractor in lieu old cable without aany extra cost.
Relaying of XLPE under ground cable after rectified the defects (Serviceable cable obtained from Item No 2 here-in-before) 6600 Volt grade, Cross sectional area 70 Sqmm to 300 Sqmm, 3 Core including Jointing and Testing complete all as specified and directed. Note:- Necessary Earth work to be measured and paid separately.
Supply and laying including taking down of XLPE insulated (Earthed), screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 6.6 KV grade, cross sectional area 70 Sqmm, 3 Core complete all as specified and directed.
All as per item No 4 here-in-before but cross sectional area 95 Sqmm, 3 Core
All as per item No 4 here-in-before but cross sectional area 150 Sqmm, 3 Core
All as per item No 4 here-in-before but cross sectional area 240 Sqmm, 3 Core
All as per item No 4 here-in-before but cross sectional area 300 Sqmm, 3 Core
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 70 Sqmm to 120 Sqmm and including preparation of burnt of HT cable complete all as specified and directed.
All as per item No 9 here-in-before but of size 240 Sqmm to 400 Sqmm
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 70 Sqmm to 120 Sqmm and including preparation of burnt of HT cable complete all as specified and directed.
All as per item No 11 here-in-before but of size 240 Sqmm to 300 Sqmm
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 70 Sqmm to 120 Sqmm and including preparation of burnt of HT cable complete all as specified and directed.
All as per item No 13 here-in-before but of size 120 Sqmm to 185 Sqmm
All as per item No 13 here-in-before but of size 240 Sqmm to 300 Sqmm
Excavation in trenches manually without using JCB not exc 1.5m wide and not exceeding 1.5m depth for foundation laying of cables etc and getting out in soft / loose soil complete all as specified and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and directed.
Rempving excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the strating point as in soil complete all as specified and directed.
Material and labour for dry river sand as in sand cushioning to under ground cable including punning down complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Relaying serviceable precast concrete cable cover obtain from item no 2 above complete all as specified and directed.
Material and labour for making of bore to road link width for providing HDPE Pipe upto 110mm dia for passing armoured cable complete all as specified and directed.
Supply and fixing of HDPE pipe 100mm dia, PE 80 IS: 14333 grade, working pressure 10 KGF / CM2 including taking out old unserviceable one complete all as specified and directed.
Supply and fixing 100mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor including taking down old unserviceable GI pipe complete all as specified and directed.
Disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity 500 KVA to 750KVA for checking the conditions to carryout repairs and Overhauling, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections as per instructions of relevant BIS Code complete all as directed by Engineer-in-Charge. Note:- Spares required for maintenance of transformer will be measured and paid seperately.
All as per ser Item No 25 here-in-before but transformer of capacity 315 KVA to 400 KVA
All as per ser Item No 25 here-in-before but transformer of capacity 200 KVA to 250 KVA
All as per ser Item No 25 here-in-before but transformer of capacity 75 KVA to 160 KVA
Supply only in repair HT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA as required at site complete all as directed (for three phases)
All as per Item No 29 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only in repair of LT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA as required at site complete all as directed (for three phases & Neutral)
All as per Item No 33 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 33 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 33 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only in repair of breather assembly complete with silica gel for transformers from above 315 KVA upto 750 KVA of any make, type and capacity of make complete all as specified and directed.
Supply only silica gel for transformer of any make, type and capacity or make complete all as specified and directed.
Supply and topping up transformer oil ISI marked in sealed containers for transformers oil,conforming to IS-335 with dielectric strength of not less than 50 KV and testing for strength including recording results complete all as specified and directed. Note:- (i) Purchase vouchers alongwith manufacturer's test certificate shall be produced to ENgineer-in-Charge. (ii) Nos of sealed containers shall be recorded in MB. Make: CASTROL / IOCL(SERVO)/HP.
Materialand labour for taking of insulating oil from transformer and check the Acid Test of insulating oil before De-hydration of transformer oil of any capacity of transformer complete all as specified and directed.
De-hydration and filtration of transformer oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 40 KV to 60 KV withstand for one minute is achieved and acidity test for any capacity of transformer complete all as specified and directed.
Supply and fixing of MS Cross arms, bracings, supports etc. incl nuts, bolts, washers, welding, bending, drilling including application two coats of aluminium paint over a coat of red oxide primer after preparation of surface including taking down old steel members complete all as specified and directed.
Material and labour for hardcore of gauge exc 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate complete all as specified and directed
Supply and fixing Cable Route indicator made out of Cast Iron plate 80mm dia fixed with MS angle iron 40x40x6mm having 60cm long showing MES HT cable size with voltage with two coats of synthetic enamel paint in brown colour over one coat of primer necessary Earth work and cement concrete 1:2:4 (20 mm crushed stone aggregate) Block of size 20cm x 20cm x 20cm including taking down old unserviceable cable route indicator complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below the normal ground level, connected with and including galvanized earth strip of size 32 x 6mm thick connected to main test point as directed as earthing lead by means of nuts, bolts, washers of galvanized iron protected by 40mm dia (light grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (medium grade) watering pipe including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @15 cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternative layers including necessary excavation and earth work in soft/ loose soil all as shown in Electric Plate No. 3 of SSR Part - I and testing including taking down old earthing complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead with 32 x 6 mm GI Strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
Material and labour for preparation of old painted steel or iron surfaces of VCB Panel of any capacity by scrapping with steel wire brush/scrapper emery paper, etc. and applying one coats of synthetic enamel smoke grey paint (painting shall be done by spray machine) including writing of SM No, MES No etc. with approved colour synthetic enamel thick paint in white back ground complete all as specified and directed
All as per item No 48 here-in-before but of old painted steel or iron surfaces of RMU of any way
All as per item No 48 here-in-before but of old painted steel or iron surfaces of VLE switches panel of any capacity
Supply & fixing Multi Function Meter LCD Display with Parameters - Amp, Volt, Freq, Load, % Unbal, Amp Phase angle, Maximum Demand including Taking down / out unserviceable Multi Function Meter complete all as specified and as directed.
Supply and fixing in repair bakelite kitkat with 2 / 5/ 10 Amps HRC fuse suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed. .
Supply and fixing in repair indicator lamp LED 110 Volt AC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed.
Supply and fixing in repair indicator lamp LED 24 Volt DC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed.
Supply and fixing in replacement Power Pack 110 V AC/110 V DC on VCB Panel complete internal wiring from Power Pack to VCB CTs and Amp Meter etc as per site requirement complete all as specified and as directed.
Dismantling old unserviceable gang operated Air breaker switch from two pole / four pole structure and Supply & fixing gang operated air breaker switch, triple pole, mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 AMps, out door type(conforming to IS specifications) HT 6.6 KV, triple pole with fixed contacts of phosphorus and bronze and a set of drop out HT fuse Assembly, Fuse carrier fitting, 9 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and directed
Supply and fixing lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp of rating 6.6KV including taking down old unserviceable lightening arrestors complete all as specified and as directed.
Supply and laying of 2.5 mm thick insulated synthetic mat of confirming to IS 15652 : 2006 and meeting the requirement of IS 5216 (Part 1, 2 & 3) IS 8437, IFC - 479 Pub-1, alongwith suitable adhesive / chemibound, PU resin, water proofing compound and sealing materials as per in service recommendation of IS : 15652 class - B suitable for working voltage upto 6.6 / 11 KV with trolley movement complete all as specified and directed.
Disconnecting of HT / LT connection of Transformer and shifting the Transformer from One Sub Stn to another Sub Stn as per site requirement with help of hydra / Lifting machine and connect the HT / LT connection complete all as specified and directed. Note:- During shifting of the transformer contractor shall replace the damaged spares if any and the cost of the same shall deemed to be included in the quoted rates.
Disconnecting of HT / LT connection of existing VLE link switch (of make MEI), taking out transformer oil, defective / worn out parts, cleaning up of the tank by removing oil, sludge, replacement of defective / worn out parts, filing of old transformer oil after dehydration and filtration (to achieve the di-electric strength not less than 50 KV), filing up new transformer oil (in addition, if any) for topping up, re-connecting all electrical connections and testing complete all as directed. Note:- (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) Major parts as under shall be measured and paid separately under this BOQ as "Supply Only" items. (iii) Dehydration / filtration of transformer oil shall be measured and paid separtely under relevant item of this BOQ. (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item.
Supply only of HT fuse (barrel fuses), capacity 40 Amps, suitable for VLE switch complete all as specified and directed.
All as per item No 61 here-in-before but of capacity 63 Amps
All as per item No 61 here-in-before but of capacity 80 Amps
Supply only of bakelite separator, suitable for VLE switch complete all as specified and as directed.
Repair / Maintenance of VCB 6.6 KV capacity, removing of trolly from VCB and checking mechanism system including dusting / cleaning by smooth brushing or dry cottopn and lubrication of moving mechanism system with suitable oil / grease including necessary inspection, ressembling, checking etc complete for smooth functioning of the equipments all as specified and directed.
TOTCO
KWALITY CONSTRUCTION
INDIA ELECTRICAL EQUIPMENTS
ARATI TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .