Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC AB199 SALT LAKE SECTOR 1 KOLKATA 700064 | 24 PARAGANAS NORTH | WEST BENGAL | 700064 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.0 L+₹1.1 L (3.22%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹36.2 L+₹3.3 L (9.93%)Rejected-Finance | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹36.2 L+₹3.3 L (9.93%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹36.8 L+₹3.9 L (11.8%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
31 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8071/B/E8
2022_MES_540409_1
GE/ALP (8071B) OF KOLKATA 2022-23
Open Tender
Civil Works
Item Rate
270 days
GE ALIPORE KOLKATA
Class D and category b (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹64,000
Yes
30 Nov 2022
23 Jul 2022
3 Sept 2022
23 Jul 2022
31 Aug 2022
6 Aug 2022
Amount
Taking down ceiling fan of any type, any make and any sweep for repairing,opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of ceiling fan, 1200mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotton binding, heat varnished and including flexbile cable for electric connection complete all as specified and as directed.
All as per item No 2 here-in-before but for 1400mm sweep. complete all as specified and as directed.
Supply only ball bearing of size 6201/6202/6203 complete all as specified and as directed.
Supply only metal bush bearing suitable for ceiling fan 1200/1400 mm sweep of any type and size complete all as specefied and as directed.
Supply only capacitor for ceiling fan 2.25 MFD complete all as specified and as directed.
Supply only capacitor for ceiling fan 2 MFD complete all as specified and as directed.
Supply only fan blade (3 Nos blade is one set) 1200 mm sweep suitable for fan complete all as specified and as directed. Make: USHA/Havells /Bajaj or equivelent make
Supply only fan blade (3 Nos blade is one set) 1400 mm sweep suitable for fan complete all as specified and as directed. Make: USHA/Havells /Bajaj or equivelent make
Supply only stepped type electronic fan regulator existing phenolic laminated sheet of AC 120/280 volt complete all as specified and as directed.
Supply and fixing as in repair of MS clamps made out of 50 x 6mm flat iron suitable for hanging of ceiling fan on pipe including necessary cutting, threading, drilling, fixing arrangement split pin, nuts, bolts washer etc complete all as specified and as directed.
Material and labour in replacement of fan hooks, hold fasts for suitable size for hanging of ceiling fan complete make good and complete all as specified and as directed.
Material and labour in replacement of GI tubing 15 mm bore 'light grade',galvanised, (Down rod) with all fitting; suitable for hanging of ceiling fan as required complete all as specified and as directed.
Material and labour for painting of ceiling fan complete, in situ of size 1200/1400mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint including preparation of old painted surfaces including writing of MES No with letters n. exc 15mm height complete all as specified and as directed.
Taking down exhaust fan/wall mounted fan of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position complete all as specified and as directed. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of exhaust fan, 300mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and as directed.
All as per item No 16 here-in-before but 350 mm sweep. complete all as specified and as directed.
All as per item No 16 here-in-before but 450 mm sweep padestal fan. complete all as specified and as directed.
All as per item No 16 here-in-before but wall mounting fan 400 mm sweep complete all as specified and as directed.
Supply only capacitor for exhaust fan 4.00 MFD complete all as specified and as directed.
All as per item No 20 here-in-before but 3.15 MFD complete all as specified and as directed.
Material and labour for preparation of exhaust fan/wall mounting fan and applying one coat of grey synthetic enamel paint by spraying using spray gun with filling cavities including writing of MES No, taking down and refixing complete all as specified and as directed.
Rewinding of Padestal fan, of size 450mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and as directed.
Rewinding of wall mounting fan, of size 400mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and as directed.
Supply and fixing in repair Loovers of exhaust fan, 300mm sweep with fixing arrangement complete all as specified and as directed.
Supply and fixing in repair Loovers of exhaust fan, 350mm sweep with fixing arrangement complete all as specified and as directed.
Supply and fixing in repair Loovers of exhaust fan, 400mm sweep with fixing arrangement complete all as specified and as directed.
Supply and fixing in repair Loovers of exhaust fan, 450mm sweep with fixing arrangement complete all as specified and as directed.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity. complete all as specified and as directed. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Supply only heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed.
All as per item No 30 here-in-before but 1.5 KW complete all as specified and as directed.
Supply and fixing in repair thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater. complete all as specified and as directed.
Supply and fixing in repair indicating lamp, 230 V, flush type, rectangular, red and green indicator suitable for water heaters. complete all as specified and as directed.
Supply and fixing in repair PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser. complete all as specified and as directed.
Supply only 450mm long brass CP connection with 2 nuts without nipple suitable for geysers. complete all as specified and as directed. Make : Jaquar Cat No 805B or equivalent approved make.
Material and labour for preparation to old painted surface of storage water heater and painting of geyser 25 ltr capacity with two coats of synthetic enamel paint (white) by using spray gun complete all as specified and as directed.
All as per item No 36 here-in-before but 35/50 ltrs capacity. complete all as specified and as directed.
Supply and fixing as in repair for split cover made out of 22 guage sheet duly painted with synthetic enamel paint suitable for water heater of 25 ltr capacity. complete all as specified and as directed.
All as per item No 38 here-in-before but 35/50 ltrs capacity. complete all as specified and as directed.
Supply and fixing as in replacement patented nano polymer coated steel inner tank of 25Ltr capacity geyser suitable for model of make: Cromption/Usha/Bajaj complete all testing and make good in disturbed surface at existing location complete all as specified and as directed.
All as per item No 40 here-in-before but for 50 ltrs capacity. complete all as specified and as directed.
Supply and fixing as in replacement copper inner tank of 25Ltr capacity geyser suitable for model of make Usha/Bajaj/Cramption complete all as specified and as directed.
Supply and fixing as in repair for non return valve, 15mm bore, screwed down high pressure, cast copper alloy, chromium plated. complete all as specified and as directed.
Supply and fixing as in repair for pressure release valve 15mm bore 'T' type at inlet/ outlet or dead weight type heavy duty. complete all as specified and as directed.
Supply and fixing as in repair for apparatus plate , including suitable for water storage heater type 25 ltrs capacity. complete all as specified and as directed.
All as per item No 45 here-in-before but for 35/50 ltrs capacity. complete all as specified and as directed.
Supply and fixing as in repair for fusible plug, calibrated 95 deg to 100 deg C suitable for water heater. complete all as specified and as directed.
Supply and fixing as in repair for glass wool, between the inner and outer vessel of water heater any type and capacity. complete all as specified and as directed.
Supply and fixing as in repair for PVC insulated flexible copper conductor cable (FRLS) 4 Sqmm 3 core , 1100 Volts grade conforming to IS 694. complete all as specified and as directed.
Supply and fixing as in repair 15mm dia GI nipple, 2" long including GI socket. complete all as specified and as directed.
Supply and fixing as in repair rubber gasket for appratus plate any type/capacity complete all as specified and as directed.
material and labour for repair havy duty Professional impact hammer Drill Machine 2000 watt complete all as specified and as directed.
Material and labour for replacement of 80-100 mfd Starting capacitor for water cooler of capacity 80/ 150 ltrs, complete all as specified and as directed. Make : Sarda/ Power or equivalent.
Material and labour for replacement of running capacitor 10 mfd for Water Cooler of capacity 80/ 150 ltrs, complete all as specified and as directed. Make : Sarada/Power or equivalent.
Material and labour for replacement of 15mm bore chromium plated push cock suitable for water cooler of any capacity as per existing shape and complete all as specified and as directed.
Material and labour for replacement of Thermostat switch for water cooler, complete all as specified and as directed. Make : Indfoss or equivalent approved make.
Material and labour for replacement of ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 15 mm complete all as specified and as directed.
Disconnecting defective sealed compress or unit of Water Cooler Upto 150 ltrs capacity from the water cooler and fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed.
Material and labour for replacement of door gasket for 150 ltrs capacity Water Cooler complete all as specified and as directed.
Material and labour for replacement of Door gasket for 80 ltrs capacity Water Cooler complete all as specified and as directed.
Material and labour for replacement of Starting Relay suitable for water cooler 80/ 150 ltrs capacity complete all as specified and as directed.
Material and labour for replacement of Overload protector suitable for Water Cooler of capacity 150 ltrs complete all as specified and as directed.
Material and labour for replacement of Overload protector suitable for Water Cooler of capacity 80 ltrs complete all as specified and as directed.
Material and labour for replacement of Capillary copper tube of size 0.36 mm for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for replacement of Freezer door for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for replacement of Thermostat switch (Make : Indfoss/Kelvinator) for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for replacement of Chill tray for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Disconnecting defective condensor coil of Refrigerators upto 315 ltrs capacity and replacing the same with new condensor coil and fixing in original position as per existing complete all as specified and as directed.
Material and labour for replacement of Inner lights for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Disconnecting defective sealed compressor unit of Refrigerators upto 315 ltrs capacity and fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed.
Material and labour for replacement of Door switch for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for replacement of 5 Amps, 230 Volts Plug Top complete all as specified and as directed.
Supply and fixing Digital thermometer LCD (Hygrometer ) for Indoor humidity and tempratuer sensor complete all as specified and as directed.
Supply and refill suitable gas for Refrigrator up to 315 Ltr complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down carefully sub main wiring of size upto 16 Sqmm including making good disturbed surfaces of walls, ceilings etc complete all as specified and as directed.
Material and labour for surface type point wiring for one light/fan point controlled by One Way switch,with 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade ,controlled by one way switch drawn through and including appropriate size of PVC casing caping with all accessoriese for surface wiring including 1.5 sqmm PVC insulated un shealthed copper cable (FR-LSH) multistrand conductor 1100 Volts grade for continuity earth wire connected to each point and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick PVC laminated/bakalite sheet cover complete all as specified and as directed.
All as per item No 77 here-in-before but for 3 Pin socket outlet 5 Amps same board with other switches with cable 1.5 Sq mm size complete all as specified and as directed.
All as per item No77 here-in-before but for 3 pin 5 Amps independent board complete all as specified and as directed.
All as per item No 77 here-in-before but for 3 pin 5 Amps independent in the same vertical plane/below the switch board of light/socket points with cable,1.5 Sq mm size. complete all as specified and as directed.
All as per item No 77 here-in-before but for 5 pin 15 Amps switch socket combination on independent board with 2.5 Sqmm cable. complete all as specified and as directed.
All as per item No 77 here-in-before but for power supply unit consisting of starter or 5 pin 15Amps switch socket combination on independent board with 4.0 Sqmm cable.
All as per item No 77 above but for one buzzer point controlled by one bell push complete all as specified and as directed.
All as per item No 77 above but for one light point controlled by two way swithces with cables 1.5 Sqmm size complete all as specified and as directed.
Material and labour for socket outlet 2 in 1,3 pin, 5 Amps, 240 V on same board complete all as specified and as directed.
Material and labour for switch socket combination 3 pin 15 Amps, 240 V Flush type, complete all as specified and as directed.
Material and labour for switch socket combination 5 pin 16 Amps, flush type, 240 Volts, universal complete all as specified and as directed.
Material and labour for power supply unit consisting of starter with 20 amps over load protection, MCB-20 amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC complete all as specified and as directed.
Supply and fixing switch piano type 5 Amp, single pole one way complete all as specified and as directed.
Supply and fixing Buzzer call bell AC 230 Volt single pole. complete all as specified and as directed.
Material and labour for bell push 5 Amp complete all as specified and as directed.
Supply and fixing for ceiling rose surface backelite 65 x 50mm three terminal complete all as specified and as directed.
Supply and fixing switch piano type 5 Amp two way complete all as specified and as directed.
Supply and fixing in repair for stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Supply and fixing in repair for socket outlet 2 in 1, 3 pin, 5 Amps, 240 V on same board complete all as specified and as directed.
Supply and fixing in repair for switch socket combination 3 pin 15 Amps, 240 V Flush type complete all as specified and as directed.
Supply and fixing in repair for power supply unit consisting of starter with 20 amps over load protection, MCB-20 amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC after taking down old one complete all as specified and as directed.
Supply and fixing in repair for switch piano type 5 Amp, single pole one way complete all as specified and as directed.
Supply and fixing in repair for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing in repair for Buzzer call bell AC 230 Volt single pole complete all as specified and as directed.
Supply and fixing in repair for bell push 5 Amp complete all as specified and as directed.
Supply and fixing in repair for ceiling rose surface backelite 65 x 50mm three terminal complete all as specified and as directed.
Supply and fixing in repair for switch piano type 5 Amp two way complete all as specified and as directed.
Supply and fixing in repair of MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA. complete all as specified and as directed. Make-Legrand Cat No-4085-87 to 4085-95 or equivalent grading ISI marked.
Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts, breaking capacity 10KA complete all as specified and as directed. Make-Legrand Cat No-4086-18 to 4086-20 or equivalent grading ISI marked.
Supply and fixing in repair MCB TPN, 63 Amps, 240 Volts, breaking capacity 10KA complete all as specified and as directed. Make - Legrand Cat No-4087-02 or equivalent grading ISI marked.
Supply and fixing in repair MCCB TPN, 160 Amps, 240 Volts , breaking capacity 25KA complete all as specified and as directed. Make- Legrand Cat No-4200 57 or equivalent grading ISI marked.
Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.
Supply and fixing as in repair MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.
Supply and fixing as in repair MCB DB SPN (double door) 2 ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.
Supply and fixing as in repair MCB DB TPN (double door) 4 ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.
Material and labour for sub main wiring for main DBs to Sub DBs with standard copper conductor 1100 volts grade of size 4 sqmm two runs of multistrand unsheathed PVC insulated cable (Red colour cable used for live connection & Black colour cable used for neutral connection) and 4 sqmm copper multistrand conductor 1100 volts grade multistrand un-sheathed PVC insulated (Green colour cable used) cable for earth continuity wire connected from main earth through PVC conduit of size 25mm for with all accessories complete all as specified and as directed. Note : Two runs of 4 sqmm and one run of 4 sqmm cable with PVC conduit shall constitute one unit.
Supply and fixing for sub main wiring(surface type) for main DBs to Sub DBs with PVC insulated & unshaethed four two run of 6 Sqmm single core multistrand copper conductor cable, 1100 Volts grade alongwith one run of 6 sqmm PVC insulated & unshaethed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuity conductor, with PVC conduit / casing caping of size 25mm for with all accessories complete all as specified and as directed. all as directed by the Engr-in-Charge. Note : (a) Two runs of 6 sqmm and one run of 6 sqmm cable with PVC conduit shall be constitute one unit.
Material and labour for sub main wiring as in repair wiring (surface type) for main DBs to sub DBs with PVC insulated two runs of 10 sqmm single core multistranded copper conductor cable , 1100 volts grade, along with one run of 10 sqmm PVC insulated & unsheathed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuty conductor , through PVC conduit / casing caping of as required for with all accessories complete all as specified and as directed. Note : Two runs of 10 sqmm and one run of 10 sqmm cable with conduit pipe shall be considered as one unit.
Supply and fixing for sub main wiring(surface type) for main DBs to Sub DBs with PVC insulated & unshaethed four runs of 16 Sqmm single core multistrand copper conductor cable, 1100 Volts grade alongwith two run of 16 sqmm PVC insulated & unshaethed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuity conductor, with PVC casing capping/PVC conduit of suitable size with all accessories complete all as specified and as directed. Note : (a) Four runs of 16 sqmm and two runs of 16 sqmm cable with PVC conduit shall be constitute one unit.
Material and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 500 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and as directed.
Supply and fixing earth continuity conductor of 25x4 mm galvanised iron strip with saddle and fixing screw for conductor above ground, complete all as specified and as directed.
Supply and fixing Electronic LED light fitting Driver Up to 36 watt complete all as specified and as directed.
Supply and fixing in repair main terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing main switch board of any size (housing of switches, sockets outlets, regulators etc) complete including making good with existing colour of disturbed surfase of wall complete all as specified and as directed.
Supply and fixing in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size housing of at least one switch sockets outlets15 Amps etc complete including making good with existing coulor of disturbed surfase of wall complete all as specified and as directed.
Supply and fixing in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size housing of at least one switch sockets outlets 5 Amps etc complete including making good with existing colour of disturbed surfase of wall complete all as specified and as directed.
Supply and fixing in repair bakelite laminated sheat top cover 3mm thick of existing size main switch board (mounting of switches,sockets outlets,regulators etc) complete including refixing seviceable switches, switch sockets and regulators etc complete all as specified and as directed.
Supply and fixing in repair bakelite laminated sheat top cover 3mm thick of existing size for mounting of ,switch sockets outlets 15 amp, etc complete including refixing seviceable switch sockets etc complete all as specified and as directed.
Supply and fixing in repair bakelite laminated sheat top cover 3mm thick of existing size for mounting of switch sockets outlets 5 Amp etc complete including refixing seviceable switch sockets etc complete all as specified and as directed.
Tirupati Buildcon Pvt. Ltd.
SOVA ENTERPRISE
M. M. C. AND CO
M/S. CHAKRABORTY ENTERPRISE
GAYATRI ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .