Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹30.0 L+₹21,367 (0.72%)Rejected-Finance TARIN JALAL NAGAR SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹34.2 L+₹4.4 L (14.8%)Rejected-Finance 687 ARYA NAGAR POWAYAN ROAD SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹34.6 L+₹4.9 L (16.4%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹35.5 L+₹5.7 L (19.3%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
18 Jan 2024, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
PROVN OF PQC PATH INFRONT OF STAFF QUARTERS OF KV NO. 2 AND CERTAIN MINOR WORK AT MIL STN SHAHJAHANPUR UNDER GE (E) BAREILLY.
2023_MES_634100_1
8313/E8
Open Tender
Civil Works
Item Rate
183 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹83,000
Yes
22 Feb 2024
22 Dec 2023
20 Jan 2024
22 Dec 2023
18 Jan 2024
4 Jan 2024
22 Dec 2023 - 29 Dec 2023
Amount
M&L for Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning , filling in, including spreading , levelling , watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
M&L for Surface dressing n. exc (not exceeding) 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material out side of MOD land and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M & Lfor PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for providing cement concrete type B-1 1:2:4 (20 mm graded aggregate) as in bed block hold fast, coping, benching etc complete all as specified and directed.
M & L for RCC 1:1.5:3 type A-1, using 20 mm graded stone aggregate as in column footing, foundation including raft footings, plinth beam, bases of columns etc complete all as specified and directed.
M & L for RCC 1:1.5:3 type A1using 20 mm graded stone aggregate as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC 1:1.5:3 Type A1 using 20 mm graded stone aggregate as in colums, pillars etc complete all as specified and directed.
M & L for RCC type A-1, 1:1.5:3 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves and the like complete all as specified and directed.
Use and waste form work to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical or to batter of rough finished surfaces complete all as specified and directed.
Use and waste form work Square, rectangular or polygonal to sides of columns, pillars etc. of rough finished surfaces complete all as specified and directed.
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n. exc. 200 mm thick, rough finished surface of concrete complete all as specified and directed.
Use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of rough finished surfaces complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20 cm for rough finished surface complete all as specified and directed.
M&L for Steel reinforcement TMT bars 10 mm dia and over cut to length, bent to shape and tying with annealed MS wire 0.9mm dia all as specified and directed.
Ditto but 6mm to 8mm dia complete all as specified and directed.
Ditto' all as per Item above but 5mm dia and over upto and incl 10 mm dia as in Binders,stirrups,spacer complete all as specified and directed.
M&L brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 complete all as specified and directed.
M&L brick work with sub class ‘ B’ bricks straight or curved on plan exc 6 m mean radius build in CM 1:6 complete all as specified and directed.
M&L half brick thick brick work with sub class "B" bricks straigth or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified.
M&L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surface of wall finished even and fair complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface using water proofing compound @ 3% by weight of cement content or as per manufacturer's instruction. Note- integral WPC shall be measured and paid separately
Supply only integral water proofing compound complete all as specified and directed.
M&L Rendering 05 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement as in ceiling complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, cornices etc and applying two coats of cement base paint over a coat of cement wash with portland cement slurry to a smooth bodied finish complete all as specified and directed.
M&L for preparing new plastered or un plastered surfaces of walls and applying three coat of white wash including preparation of newly plastered surfaces complete all as specified and directed.
M&L applying two coats of cement based paint over one coat of cement primer on newly plastered surfaces of wall including preparation of surface complete all as specified and directed.
M&L for preparing new plastered or un plastered surfaces of ceiling and applying three coat of white wash including preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparation of roof, roof plaster and applying a coat of hot bituminous primer @ .30 kg/sqm and applying a coat of industrial bitumen 85/25 @ 1.20 kg/sqm over primer and laying modified polymeric water proofing membrane(weight not less than 4 kg/sqm 3 mm thick consisting 100 mm micron HMHDE FILM ) and applying one coat of industrial btumen grade 85/25 @ 1.2 kg/sqm on top of membrane with 100 mm overlap at side end lap where required over 10 mm thick rendering in CM 1:4 including integral waterproofing compound 3% and taking down existing plastering as per manufacturer instruction and complete all as specified and directed.
M&L broken stone hard core of gauge n. exc 63mm deposited, spread and levelled in layers n. exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L machine cut Kota stone slab 18 to 20 mm thick as in flooring or trades of step incl half round moulding over and including screed bed 20 mm thick in CM (1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified.Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size complete all as specified and directed.
Description same as above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:3, complete all as specified and as directed.
M&L PCC 1:3:6 type C2, 75 mm thick laid as in plinth protection/paving etc finished even & smooth with out usnig extra cement complete all as specified and directed
S&F pressed steel frames( factory made) made of size 1.25mm thick MS steel for door with one or more rebates incl lugs,hinges hold fast, lock strike plate etc complete of size 125 x 60mm including one shop coat of red oxide primer, PCC 1:3:6 as in back fill to chowkats complete all as specified and directed.
S&F 35mm thick 2nd class hardwood plain framed panneled factory made shutters ( two panels) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veeneering on both faces fitted to cowkhats complete all as specified and directed.
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F extruded aluminium alloy handles 150mm long 'D' type anodised complete ISI Marked complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 200 mm long complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing with nut and bpolt of ISI Marked complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new or previously untreated wood and wood based surface over a coat of pink primer including preparation complete all as specified and directed.
S&F Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS sheet tube factory made with double side shutters wire gauged shutter&glass glazed shutter (wire cloth and glass panes will be measured and paid seperately)with side hung shutters with MS handles and MS peg stay dovetailed or welded incl 02 Nos MS Tower bolts 150 mm long for each leaf and 08 mm square bar grill/guard bars at spacing as shown on Drg welded MS flat iron frame work ,including other fittings ,hinges ,MS handles ,tarred hold fasts ,PCC blocks for hold fasts etc all as shown on Drg No CEPZ/TD -354/09 sheet 1/3 to 3/3 including one coat of of red oxide zinc primer complete all as specified and directed.
S&F Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane 3mm thick complete all as specified and directed.
S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M/L preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F GI wire 3.20 mm dia for hanging clothes with tightening arrangements & stiffening to be fitted to wall for 3 RM complete all as specified and directed.
S&F for Joist, channel , angle or tee sections, tubular sections, fixed independently without connecting plates etc (cut to ordinary lengths i.e. within 20mm of the length indicated of FE 410 W (Gde E-250) quality 'A'. complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required Exc. 150 sq. cm but n exc 400 sq. cm. complete all as specified and directed.
S&F galvanised 2 strand , steel barbed wire 2.24mm dia barbed within 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including , securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured ) complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of brick work in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floor and paving exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110mm set and jointing with solvent cement complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall all as specified includin MS clamp complete all as specified and as directed.
S&F 75 mm bore. PVC (SWR) bends complete all as specified and as directed.
S&F 75mm bore.PVC(SWR) junction single (single T) equal or unequal with access door complete all as specified and directed.
S&F, GI tube 15 mm dia medium grade with all fittings and fixed to wall, ceiling or laid in floors complete all as specified and as directed.
S&F angle cock cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed both end for iron pipe or or brass ferrule for 15 mm bpre of pipe complete all as specified and as directed.
S&F in repair vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe complete all as specified and as directed.
S&F in repairs 15mm bore pillar tap cast copper allloy with capstan head Chromium plated scwed down with or without letter Hot or Cold with long shank and fly nuts scrwed for iron pipe and fixed complete all as specified and as directed.
Supply only 32mm dia wast fittings brass chromium plated for basin with long screwed shank and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F in repair PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floor for pavings n.exc 15cm thickness (below are above ground level) complete all as specified and as directed.
M&L conc as in coping ,mud stop, coveroing the pipe in CM 1:2:4 finished even and smooth complete all as specified and as directed.
S&F in repair 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer complete all as specified and as directed.
Finishing surface of concrete roads, pavements, by brooming complete all as specified and directed.
Pavement quality concrete(PQC) of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean , hard strong, dense non-porous and durable pieces of crushed stone gravel, fine aggregates of clean natural sand crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width , including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Required surface texturing to be done as specified in Clause 10.1.14 and Tabl~ 9 of IRC' 15-2017
Forming 25 mm width expansion joint in concrete slab for full depth of POC. Early entry saw and subsequent cutting by using diamond bit cutter of appropriate size. straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. The joint then filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified thereafter application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacture complete as specified and directed.
Cutting of construction joints 25 mm deep and 10 mm wide by early entry saw cut using diamond bi cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and the debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked olyethylene foam backup rod of 12 mm dia, application of bond breake tape on top of back up rod for complete width of the joint and filled with polyurethane based sealan complying with BS-5212, BS 4254 and EN- 141875-2003 with minimum movement accommodation factor (MAF) of +I- 30% having minimum 10 years performance guarantee, applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed.
M&L precast cement concrete type B1 1:2:4 (20mm graded stone Aggr) in kerb stone of size 300x150x300 (LxWxD) and set in CM 1:6 complete all as specified and directed.
M&L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub floor, sub base of floor/hard standing/foot path complete all as specified and directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Material and Labour for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC conduit concealed and conduit accessories of suitable dia medium grade and pressed steel terminal boxes suitable for swiches size and duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with suitable for fixing switches / sockets/ regulators including fixing all accessories etc including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed.
One light/fan point controlled by one switch.
S&F Switch piano type single pole one way flush type 5 Amps capacity 230 volts complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 5.00 BEE. with brushless direct current motor (BLDC) complete all as specified and directed.
S&F Nut & Bolt set U type hook hanger with Fasteners for hanging Ceiling fan golden set of 1 (Mild steel) all as per specified and as directed.
S&F ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified and directed.
M&L for Point wiring in concealed PVC conduit using stranded copper conductor cable of size 2.5 Sqmm, PVC insulated unsheathed FRLS cable complete with all fittings and accessories but using existing sunken cast iron or pressed steel terminal box for mounting of switches, sockets, fan regulators etc but providing new cover 3mm thick laminated,(Hylem) sheet top cover fastened with chromium plated screws and 2.5 Sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly all as directed and as specified. NOTE: for wiring in ceiling portion conduit shall be fixed with surface of ceiling/with trusses etc.
One 3 pin socket outlet 15 Amp on independent board.
S&F switch piano flush type polycarbonate SP one way 15 Amps complete all as specified and directed.
S&F socket out let 3 pin 5/15 Amp multipurpose, flush type 240 volt complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc including making connection complete all as specified and as directed.
S&F 15mm bore GI water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F 15mm bore angle stop valve of cast copper alloy chromium plated high pressure screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing Bip tap 15mm dia ,cast copper alloy chromium plated fency type with crutch or butter fly handle screwed down for iron pipe or brass ferrule and fixed complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
M & L for Cutting of wall for exhaust fan of any size and sweep and necessary fitting such as nut bolt and washers & Fastner and to make as per existing colour to match the wall complete all as specified and directed.
M/S SHAHABUDDIN AND SONS
M/S MANSI TRADERS
UTTRAKHAND BUILDERS
M/S CHAUHAN ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .