Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 CrAccepted-Finance | ₹11.6 Cr | L1 | Accepted-Finance Lowest rate found. |
Tender Value
₹11.9 Cr
EMD Value
₹21.9 L
Closing Date
18 Oct 2023, 2:00 pmClosed
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
CONSTRUCTION OF BOUNDARY WALL,VARIOUS FACILITIES, INSTALLATION OF SECURITY EQUIPMENTS AND BAGGAGE HANDLING SYSTEM AND OTHER ALLIED REMAINING WORKS OF AIRPORT TERMINAL BUILDING, DAMAN. (5th call) (E-30226)
2023_DAMAN_3102_1
Tender Notice No.79/01/2023-24
Open Tender
Civil Works
390 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe.,Engg., PWD, WD-I, Daman.
₹21.9 L
The Exe.,Engg., PWD, WD-I, Daman.
28 Oct 2023
20 Sept 2023
18 Oct 2023
20 Sept 2023
18 Oct 2023
20 Sept 2023
26 Sept 2023
Amount
Civil work
BOUNDARY WALL (AIR SIDE & CITY SIDE): (A) CIVIL WORKS, 1)- EARTHWORKS:- Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering
Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to 100 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 100 m to 200 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 200 m to 300 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 300 m to 400 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 400 m to 500 m
2)- CONCRETE WORKS:- Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum- i)- All works upto plinth level
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum ii)-i All works above plinth level upto floor V level
Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level
Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10mm to 16mm dia bar
3)- FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns Pillars Posts and struts. (1) Square Rectangular Polygonal in plan.
4)- MASONARY WORK:- Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional.Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
5)- FINISHING:-20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement: 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement: 1-sand) etc. complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
6)- MISCELLANEOUS WORKS:- Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A) In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like
TAXI WAY LINK 52M LENGTH GATE (A) CIVIL WORK 1)- EARTHWORK:-Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to 100 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 100 m to 200 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 200 m to 300 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 300 m to 400 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 400 m to 500 m
2)- CONCRETE WORKS:- Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum i)-All works upto plinth level
Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level
3)- FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan. (upto 10 ton)
4)- MISCELLANEOUS WORKS:- Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
TOILET BLOCK,ENTRANCE GATE WITH GUARD ROOM & FOOD PLAZA: (A) CIVIL WORK 1)-EARTHWORK:- Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering
Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to 100 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 100 m to 200 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 200 m to 300 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 300 m to 400 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 400 m to 500 m
2)- CONCRETE WORKS:- Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level
Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10mm to 16mm dia bar
3)- FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (I) Edges of slabs and Breaks in floors and walls. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan. (upto 10 ton)
3)- MASONARY WORK:- Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional.Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
4)-WOOD WORK AND JOINERY:- Providing wood work in frames of Doors, windows cleare story windows and othersimilar works wrought, framede and fixed in position. (A) Indian Teak Wood (upto 10 ton)
Providing and fixing 35 mm thick shutters for Doors, windows and clearstory windows including blackenamelled M.S. butt hinges with necessary screws. (A) Indian teak wood. (i) Fully Panelled. (upto 10 ton)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. For fixed portion
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fiixng of Door Stopper of SS 304 Grade as directed by Engineer-in-charge.
Providing and fiixng of Door closer as directed by Engineer-in-charge.
Providing and fiixng of dead lock of SS 304 Grade as directed by Engineer-in-charge.
Providing and fiixng of Pull Handle of SS 304 Grade as directed by Engineer-in-charge.
Providing and fiixng of Mortise Lock of SS 304 Grade as directed by Engineer-in-charge.
5)-FLOOR FINISHES:- Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab upto 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskid (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick
6)- ROOFING AND CEILING WORKS:- Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/Cosmos/Spintone) in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation
Providing corrugated G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts 8mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete excluding the cost of purlins, Rafters and Trusses.(1) 0.80 mm thick sheet.
7)-PLASTER WORK:- 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement: 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement: 1-sand) etc. complete.
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
8)-PAINTING WORK:- Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
9)-MISCELLANEOUS WORKS:- Providing and fixing Toilet cubical made up of thermosetting resign treated high pressure ,self-supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing . Compact board should be resistance to water immersion through permissible increase on thickness and mass <0.60% and board density >1.35kg/cm3 and fulfilled the criteria of FSC and green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/97 and EN438-6 with classification of BS1D0 standard. Pilaster to be supported with SS(grade316) adjustable foot and intermediate panels will attached to the wall with the help of approved SS (grade316) channels and all required hardware, made up of stainless steel as per manufacturer’s specification. Door knob, gravity hinges,Thumb turn locksets with occupancy indicators ,coat hooks with door stoper , U channel, top rail with corner connector, adjustable foot/pedestal, Rubber noice deafening tape, screw & wall plugs should be approved under the instruction of Engineer-in-charge.
Providing & fixing Urinal Modesty Panels made of 12 mm thick compact laminated board of approved texture/shade having standard dimension of 1200 mm Height x 450 -500 mm Width and made as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard and should be heat, bacteria, water, chemical, scratch and impact resistant . The product should have Green Guard Certificate. Including all accessories as per approval and direction of Engineer-in-Charge .Modesty panels will be fixed to the wall at an height of 500-600mm from the floor with 304 grade SS right angle bracket, 34 grade SS Screws with satin finish & Wall Plugs. The work includes all accessories, machineries, tools etc., complete as per direction of Engineer-in- charge.
10)-WATERPROOFING :- A)-RAFT/FOOTING :- Supplying and installing minimum 1.2mm thick self-adhesive HDPE membrane, having puncture resistance of >800N (as per ASTM E 154) and hydrostatic head resistance not less than 60m head of water (ASTM D 5385).The system should be fully bonded to the RCC and consists of highly resilient HDPE film, a pressure sensitive -adhesive layer which is covered by a weather proof protective layer .The membrane shall have minimum of 75mm side and end laps which shall be sealed with double sided adhesive tape. The size of the membrane should not be less than 2.4Mtr. x 20 Mtr. to minimize the joints. No Protection Required for Fully Bonded HDPE Membrane Allowing Faster Constructions. The entire waterproofing treatment should be guaranteed by the principal manufacturer as a system, for ten years and the work should be executed as per manufacturer commendations, all in accordance to technical specification as per the direction of Engineer-In-Charge.
B)- TOILETS/SUNKEN TOILET Minor cleaning work, removal of loose concrete and filling cracks and making angle fillets all around the periphery with polymer modified mortar using SBR latex. Supplying & applying 2 coats of Acrylic cementitious coating with an elongation of >40%@ 0.6-0.7 sq mtr per kg in two coats in the sunken areas & extending it up to 300 mm above the finished floor level achieving a uniform thickness of 1.0mm . This includes laying of a 150mm wide strip of an open woven glass fiber mesh over the angle fillets on the 1st coat while it is still wet Supplying & laying a protective plaster in 15mm thickness in Sand Cement mortar(1:4) admixed withSBR Latex mixed compound, all in accordance to techincal specification as per the direction of Engineer-In-Charge.
C)- TERRACE Supplying and apply single component cold applied polyurethane elastomeric membrane, having solid content 90% as per ASTM C836,elongation at break of 400% ASTM D-612, hardness 75 shoreA, as per ASTM D2240 @1 kg/m2, brush applied waterproofing coating, Providing & Laying a protection layer of 200 gsm geo-textile membrane with an overlap of 50mm over the waterproofing membrane.
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like
BAGGAGE HANDLING SYSTEM WITH AMC: SUPPLYING AND INSTALLATION OF BAGGAGE HANDLING SYSTEM CONSITING OF THE FOLLOWING SCANNING CONVEYOR OF APPROVED MAKE AS DIRECTED BY ARCHITECT/EIC.– SIZE:- 2500MM LONG X 750MM WIDE X 750MM HEIGHT (WORKING WIDE- 600MM) TECHNICAL DATA:- 1) TRACK -4MM THICKNESS 2) M.S LEGS STRATURE IN SQ. TUBE 50X50MM THICK WILL BE PROVIDED WITH THE SYSTEM 3) M.S HARD CHROME PLATED DRIVE & DRIVEN ROLLER WITH EN-8 SHAFT & NTN BRG WILL BE PROVIDED WITH THE SYSTEM 4) PVC BLACK BELT-3MM THICK X 600 WIDTH WILL BE PROVIDED WITH THE SYSTEM 5) RETURN SIDE PVC IDLER Ø 42MM WITH SHAFT 6) MOTOR – 1HP HINDUSTAN MAKE 1400RPM WITH GEARBOX WILL BE PROVIDED WITH THE SYSTEM 7) DRIVE- CHAIN SPROCKET TYPE DRIVE 8) DRIVE & DRIVEN PLATE WITH SCREW TYPE BELT ALIGNMENT WILL BE PROVIDED WITH THE SYSTEM 9) SYSTEM WILL BE POWDER COATED AS PER YOUR SPECIFIC COLOUR SHADE.
BELT CONVEYOR ( BHS) OF APPROVED MAKE AS DIRECTED BY ARCHITECT/EIC A. SIZE:- 20000MM LONG X 1000MM WIDE X 400MM HEIGHT ( WORKING WIDE-800MM)
BELT CONVEYOR ( BHS) OF APPROVED MAKE AS DIRECTED BY ARCHITECT/EIC B. SIZE:- 15000MM LONG X 1000MM WIDE X 400MM HEIGHT (WORKING WIDE-800MM)
SECURITY EQUIPMENTS WITH AMC: Supply, Installation, Testing & Commissioning of Long Range Proximity Card Readers/RFID reader 10-12 mtr read range with suitable mounting arrangement for Outdoor Application and shall be compatible with boom barrier and controller to integrate further with unified software platform for optional mobile view. (Main Entry and Vehicle Material Gate Ingress & Egress.) Approved Make : HID/HONEYWELL/ATROSYS/FAAC or Equivalent to be approved by Architect/ EIC.
Supply Installation Testing & Commissioning of 3mtr pole for mounting of RFID reader with all accessories complete as required.
Supply, Installation, Testing & Commissioning of Automatic Boom Barrier of 7 mtr boom length as per detailed technical specifications, Outdoor- IP 54, Barrier Housing Unit: Powder Coated- Boom,100% Duty Cycle, barrier shall use a Blockable DC Drive, in combination with microprocessor-based controller, inbuilt with smart i/o box, It shall offer LCD Display easy control setting, 230+/- 10% VAC, 50 Hz. 20 Degree Celsius to + 70 Degree Celsius- Modular GI housing with powder coating, aluminium boom with powder coating, All Housing and internal parts will be rust & corrosion free metals or alloys of high strength with suitable Epoxy coating as applicable, 345mmX240mmX1020mm, Inbuilt Smart I/O box to integrate with third party to attain various functionalities.Approved Make : FAAC/MAGNETIC/ATROSYS/KAVA or Equivalent to be approved by Architect/ EIC.
Supply and programming of Tamper proof RFID Tags along with facility code as per specifications.Approved Make : HID/HONEYWELL/ATROSYS/FAAC or Equivalent to be approved by Architect/ EIC.
Supply Installation Testing & Commissioning loop detector with loop coil to close the boom barrier automatically and safety with all accessories complete as required incuding all civil works.
Tyre killer - Blocking width Maximum of 6-7 m, Dia of Spike 15 mm, width of spike 100 mm Height of Spike Above road surface, Not lesser than 80 mm, Height of The Block Flush to road level Width of The Block Not more than 1.5 Meters, Foundation depth Approx. 150mm and upto 600 m Angle of spike in raised position 90 deg, Distance between c/c adjacent spike Not more than 125 mm Operating power 230 FAAC/ MAGNETIC/ ATROSYS/ KABA ̴ +10%, 50Hz, Operating temp 0 to 50 deg Celsius, Control unit Micro controller Axle load bearing capacity Minimum 4 Ton Per Axle, Material of Cabinet , M.S Galvanized, Material of spike MS EN8 carbon steel. Zinc electroplated & powder coated, Colour Spikes – yellow. Top surface is grey/silver color, Protection class IP55 for the Drive Head Inbuilt Smart I/O Box (Smart IOT box to have third party integrations.).Approved Make : FAAC/MAGNETIC/ATROSYS/KAVA or Equivalent to be approved by Architect/ EIC.
Supply, Installation, Testing and Commissioning of X-Ray Baggage Inspection systems, Physical Specifications X-ray Baggage Scanner Unit weight (kgs) 455 Unit size (mm) 2007(L)*868(W)*1314(H) after packed in wooden pallet – Gross weight (kgs) 500 Packing size #1: 212*101*156cm #2: 87*87*141cm General Specifications Tunnel size(mm) 615(L)*418(W) Conveyor Speed(m/s) 0.22 Conveyor height(mm) 680 Conveyor Max Load(kgs) 150 X ray dose per each inspection Typical 2.0 μGy/h, guarantee 2.5 μGy/h X ray leakage Typical1.0 μGy/h, guarantee 1.5 μGy/h Penetration Typical 32mm, guarantee 30mm Wire Resolution Typical AWG40, guarantee AWG38 Penetration Resolution Typical AWG32, guarantee AWG30 Spatial resolution: Typical dia1.0mm,Vertical: dia1.0mm; Guarantee dia1.3mm,Vertical: dia1.3mm; Power Consumption 0.8KVA Noise < 60dB Film Safety Guarantee ASA/ISO1600 Film.Approved Make : RAPISCAN/SMITH/PMI/VOTI or Equivalent as per BCAS norms DUAL VIEW to be approved by Architect/ EIC.
Supply, Installation, Testing and Commissioning of X-Ray Baggage Inspection systems, Physical Specifications Unit weight (kgs) 850 Unit size (mm) 3638(L)*1295(W)*1916.5(H) after packed in wooden pallet – Gross weight (kgs) 950 Packing size #1: 287*142*213cm #2: 113*89*142cm General Specifications Tunnel size(mm) 1010(L)*1003.5(W) Conveyor Speed(m/s) 0.2 Conveyor height(mm) 334.5 Conveyor Max Load(kgs) 200 X ray dose per each inspection Typical 1.5 μGy/h, guarantee 2.0 μGy/h X ray leakage Typical 1.0 μGy/h, guarantee 1.5 μGy/h Penetration Typical 10mm Wire Resolution Typical AWG36 Penetration Resolution Typical AWG24, guarantee AWG24 Spatial resolution: Typical dia2.0mm,Vertical: dia2.0mm; Guarantee dia2.0mm,Vertical: dia2.0mm; Power Consumption max. 1KW Noise < 60 dB Film Safety Guarantee ASA/ISO1600 Film. Approved Make : RAPISCAN/SMITH/PMI/VOTI or Equivalent as per BCAS norms(DUAL VIEW) to be approved by Architect/ EIC.
Supply, Installation, testing and commissiong of Walk Through Metal detector, The DFMD should have multizone capability with minimum 8 zones of detection with uniform sensitivity in all zones, Operating temperature range of 0 to +45 C with RH up to 95 %, non-condensing. , and as per technical specification.Approved Make : RAPISCAN/SMITH/ATROSYS or Equivalent as per BCAS/NIJ norms to be approved by Architect/ EIC.
Supply, Installation, Testing and commissioning of Hand held Metal Detector temperature range from 0°C to 45°C with Operating frequency (90-95 kHz), Rugged high impact case, and as per technical specifications.Approved Make : RAPISCAN/SMITH/ATROSYS or Equivalent as per BCAS/NIJ norms to be approved by Architect/ EIC.
Supply, Installation, Testing and Commissioning of Retractable Hydralic bollard,Bollard shall be fully operational within following conditions: Operating temperature-15 °C / +55 °C, It’s supplied with 230VAC voltage – 50Hz, Drive Hydraulic unit, Smart Programming Box- Programming box to integrate with other third-party systems seamlessly. Cylinder height from ground [mm]800, Cylinder diameter [mm]275, Cylinder material MS powder coated with SS 316 cover.Approved Make :GUNNEBO/MAGNETIC/ATROSYS/FAAC or Equivalent as per BCAS norms to be approved by Architect/ EIC.
UVSS- AREA SCAN, i. Camera Type Gigabit Ethernet progressive camera, ii. Sensor CMOS XGA resolution (1920 x 1200) or better, iii. Field of View > 135, iv. Format GiGE Vision compliant specifications v. Composite Image resolution of the underside 4 megapixel, vi. Camera certification CE vii. Camera casing ingress protection rating IP 67 or better, duly certified by NABL accredited lab, speeds ranging from Zero (0) to 25 Km/hr as per detailed technical specifications. Approved Make : EASYVIGIL/ATROSYS/COMM-PORT or Equivalent as per BCAS/NIJ norms to be approved by Architect/ EIC.
SECURITY EQUIPMENT AND VIP LOUNGE FURNITURE: STAMPING TABLE Supplying and placing Stamping Table, comprising of 18mm thick Particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes , 30x30 mm framework of salwood, laminate of approved make fixed over particle board at all sides by using adhesive of approved quality, at top lipping to be made at edges with 100mm high deep drawer at front with channels and hardware.,, all complete as per design/drawing in the direction of Engineer-in-Charge. Overall approx. size 450(L) x 450(B) x 1200(H) mm
STAMPING STAND Supplying and placing Stamping stand, comprising of 18mm thick Particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes , 30x30 mm framework of salwood, 4mm veneer board of approved make fixed over particle board at top and all around of stamping stand by using adhesive of approved quality,, all complete as per design/drawing in the direction of Engineer-in-Charge. Overall approx. size 736(L) x 296(B) x 1200(H) mm & 650(L) x 752(B) x 150(H) mm
FRISKING BOOTH Supplying and placing Frisking Booth, comprising of 18mm thick Particle board at all sides of cabin of approved make confirming to IS code 3087:2005 or other relevant IS codes , 50x50 mm framework of salwood, 4mm veneer board of approved make fixed over particle board on both sides of the booth by using of adhesive of approved quality, stainless steel rod of 20mm dia fixed at top of rare and front ends of cabin with curtains, all complete as per design/drawing in the direction of Engineer-in-Charge. Overall approx. Size 1500(L) x 1500(B) x 2400(H) mm
INFORMATION DESK Providing and fixing in position Information Desk, comprising of 12mm thick plywood of approved makes, confirming to IS 303 : 1989 or other relevant IS codes, framing of salwood, solid acrylic surface is fixed over plywood by using adhesive of approved quality at countertop, sides of desk as shown in the drawing including all necessary cutouts for electrical, fixtures, fittings etc. all complete as per the direction of the Engineer-In-Charge. Overall approx. Size 1500(L) x 1500(B) x 2400(H) mm
BOARDING PASS COUNTER:- Providing and fixing in position boarding pass counter, comprising of 12mm thick plywood of approved makes, confirming to IS 303 : 1989 or other relevant IS codes, 30x30 mm framework of salwood, 4mm veneer is fixed over plywood by using adhesive of approved quality at countertop, sides of desk as shown in the drawing including all necessary cutouts for electrical, fixtures, fittings etc. all complete as per the direction of the Engineer-In-Charge. Overall approx. Size 1000(L) x 875(B) x 1080(H) mm
LUGGAGE TABLE Supplying and placing Luggage Table, comprising of 18mm thick particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes over 30x30mm framework of salwood, 40 x 40 mm wooden table legs, beveled at edges. all complete as per design/drawing in the direction of Engineer-in-Charge. i-Overall approx. size 750(L) x 1525(B) x height as per x ray machine height
LUGGAGE TABLE Supplying and placing Luggage Table, comprising of 18mm thick particle board of approved make confirming to IS code 3087:2005 or other relevant IS codes over 30x30mm framework of salwood, 40 x 40 mm wooden table legs, beveled at edges. all complete as per design/drawing in the direction of Engineer-in-Charge. ii-Overall approx. size 900(L) x 600(B) x height as per x ray machine height
VIP LOUNGE Furniture Jinerio 3str Supplying and placing in position 3 Seater sofa of the following specifications.Upholstery : Microfibre with Polyester Laminate Frame Material : Kiln dried wood Seat Foam : Slab stock foam with recron layer. Also bonded foam used as a supporting material beneath slab stock. Foam Density : 34 kg/ cubic m. Back Foam : Slab stock foam with recron fill at back and arms. Foam Density : 34 kg/cubic m. Webbing Material : S- spring along with nylon strips. The overall dimension of the sofa shall be 2110 mm(W) x 935 mm (D) X 890mm (H).The upholstery is made of fabric. The seat and backrest is filled with recron. The frame is made up of tropical wooden.
Jinerio 2str Supplying and placing in position 2 Seater sofa of the following specifications.Upholstery : Microfibre with Polyester Laminate Frame Material : Kiln dried wood Seat Foam : Slab stock foam with recron layer. Also bonded foam used as a supporting material beneath slab stock. Foam Density : 34 kg/ cubic m. Back Foam : Slab stock foam with recron fill at back and arms. Foam Density : 34 kg/cubic m. Webbing Material : S- spring along with nylon strips. The overall dimension of the sofa shall be 1560 mm(W) x 935 mm (D) X 890mm (H). The upholstery is made of fabric. The seat and backrest is filled with recron. The frame is made up of tropical Wooden.
Mackenzie 1 str size1 seater-107cm(w)*101cm(d)*103cm(h)*51cm(sh) Upholstery : Fab leather. A fabric which gives a leather feel • Thickness of upholstery: 1 mm • Shade :1 seater - Dark Brown and blue 2 seater + storage – Dark Brown 2 seater – Dark Brown • Mechanism :Manual with there level reclining in metal • Frame : Material - Solid wood Moisture Content : 12% • Foam Density : Seat : 32 kg/ cubic meter Back : 28 kg/ cubic meter
Gayle Centre Table Supplying & placing in position oval shaped centre table of dimensions 1100 x 600 x 395. Tempered Glass Top with 8mm thickness. UV disc attached to the base with transparent glue. Base material is made of fibreglass reinforced plastic. Load bearing capacity : 40 Kg. Colour to be black.
Vegas Corner Table Overall Size including top cornice : Width (a) - DIA450-mm .Thickness (b) - 9 mm.Height (c) - 520 mm . D – 450mm Material : Temper glass ,thickness:9mm ;coating:chrome
FLAG POST: SUPPLY PART Supply of 30.5M Flag mast. Mast shaft shall be in three sections, hot dip galvanised and suitable for wind velocity as per IS 875. Mast shall be suitable for Indian Tri Color Flag Size 30Ft X 20Ft. System for Raising Lowering of Flag It shall have double drum winch, 6 mm dia Galvanised wire rope and integral power tool for the raising and lowering of Flag.Supply of system with 3C x 2.5sqmm Cu armoured cable for aviation light. PU painting of High mast shaft with a coating of etch primer, primer and PU paint.
Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates.
Supply of Aviation Lamp Single Dome Obstruction light. 1 nos. LED AOL per mast
Supply of 5M high hot dip galvanised octagonal pole suitable to mount 2 nos.flood light fitting at top.
Supply of national flag of size 30Ft X 20Ft in 100% knitted Polyester (140gsm), with reinforced super-strong nylon webbing on all 3 sides & rope/toggle sleeve.
ERECTION PART Erection of the Flag Mast with the help of suitable equipments and assembly of operating system and Flag supplied by you.
(A) CIVIL WORKS, 1-EARTHWORK:-Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50Meter lead.(A) Loose or soft soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering
2-CONCRETE:- Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (more than 10 ton)
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 Kg/Cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All work upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 Kg/Cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All work above plinth level upto floor V level
Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level
3-FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan. (upto 10 ton)
4-FLOORING:- Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.
310M WIDE (VEHICULAR)VILLAGE DRAIN : A)-CIVILWORK,1)-EARTHWORK:- Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering
Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to 100 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 100 m to 200 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 200 m to 300 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 300 m to 400 m
Add extra for Disposing off the excavated stuff of above items for lead of (A) 400 m to 500 m
2)-CONCRETE:- Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum i-All works upto plinth level
Providing Primary TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Upto and above plinth level
3)-FORMWORK:- Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto 10 ton)
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth. (upto 10 ton)
4)-MISCELLENEOUS:- Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10mm to 16mm dia bar
FACAD CLEANING ACCESS SYSTEM WITH AMC : Design, Manufacturing, Supply, Transportation, Installation, Commissioning of Façade Access System of Approved make as directed by EIC: - BMU Type 01- Vertical Mast Lift (Over Hung Canopy) Vertical Mast Lift (Working Height = 12m.)
BMU Type 02- Aluminium Scaffold Tower Aluminium Scaffold Tower (Working Height = 12m.)
BMU Type 03- Telescopic Cleaning Pole Telescopic Cleaning Pole (Max. Working Height = 10m.)
BMU Type 04- Inverted V-shaped Aluminium ladder Inverted V-shaped Aluminium Ladder (Working Height = 12m.)
(B)-ELECTRICAL INTERNAL,1-Wiring:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire.
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire.
2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire
2x10 sq. mm + 1x6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or c utting the wall and making good the same in case of recessed conduit as required. a- 20 mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mm x 75 mm) (For Telephone, Data, TV Outlets)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2)-Fans and Fittings:- Supply, Installation, Testing and Commissioning of following fittings on the existing point with making connection with 1.5 sqmm FRLS Copper conductor single core cable i/c earthing etc. As required. Note: All LED Fixtures shall have power factor ≥0.90 (For item No 1 to 5) Supply of Surface/recess type LED (direct/indirect) of 595 x 595 mm size with aesthetically designed extruded aluminium housing & injection molded PC component diffuser with efficacy better than 120 Lumen/watt (minimum total lumen delivered package 4800), with CCT=3000/4000/5000 K,PF>0.95,THD<10% & with Driver having efficiency >85% .Service life of 50,000 hrs @ L 70 etc complete as required. (Driver complaince IEC 62384,IEC 61547,IEC 61347-2-13,EMI-CISPR15)
Supply of Surface/recess type LED downlighter neutral white (4000 K) with LED having pressure die cast aluminium hang body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50000 hrs having system lumen output better than 1000 lumens and efficacy better than 100 lumen/ watt(fixture design for meeting LG-7 Guideline) with CRI>80, Reverse Polarity and Surge Protection upto 3 kV& Driver efficiency> 90%,PF>0.98,THD<5% (Driver complaince IEC 62384,IEC 61547,IEC 61347-2-13,EMI-CISPR15) etc. complete as reqd.
1200/1400 mm sweep BLDC ceiling fan providing minimum air delivery of 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM,service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remote alongwith necessary down rod of standard length (upto 30cms)
900 mm sweep BLDC ceiling fan providing minimum air delivery of 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM,service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remote alongwith necessary down rod of standard length (upto 30cms)
Supply ,Installation , testing ,Commissioning AC Exhaust Fan 300mm (12") Sweep (Light Duty).All complete complying with relevant standard specification and as directed by the departmental officers.
10W Mirror Light
70W LED DOWN LIGHTER SURFACE MOUNTED
3)- Distribution Boards:- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Double door
6 way, Double door
8 way, Double door
12 way , Double door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB
For 8 way, Double door SPN MCBDB
For 12 way, Double door SPN MCBDB
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required.40 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.40 Amp
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Lighting Fixture Supply , Installation, Testing & commissioning of the followings:- Post top (Gate Light) luminaire with system wattage 27W. The luminaire shall be with BIS certification for Luminaire on 3.0M GI Pole.
Street Light luminaire with system wattage 65W.The luminaire shall be with BIS certification for Luminaire.
LED BOLLARD with system wattage 8-11W & high level of durability with high impact resistance.The luminaire shall be with BIS certification for Luminaire.
LED Spike light with high level of durability with high impact resistance. The luminaire shall be with BIS certification for Luminaire.
Poles - Supply & Erection of 7.5 Mtr. high (above Ground) GI OCTAGONAL street light pole alongwith bracket and all accessories in reinforced cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation of size 40x40x150 cm, including excavation and refilling, positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 50 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole i/c cable termination etc complete as required. (For street Light Single Arms)
2)- LT CABLE AND TERMINATION- SSupplying & laying one number XLPE insulated PVC sheathed Aluminium/Cu Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3.5 core, 50sq.mm.
3.5 core, 35sq.mm.
3.5 core, 25sq.mm.
4 core, 10 sq.mm. Cu
4 core, 6 sq.mm. Cu
4 core, 4 sq.mm. Cu
3 core, 6 sq.mm. Cu
3 core, 2.5 sq.mm. Cu
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3.5 core, 50sq.mm.
3.5 core, 35sq.mm.
3.5 core, 25sq.mm.
4 core, 10 sq.mm. Cu
4 core, 6 sq.mm. Cu
4 core, 4 sq.mm. Cu
3 core, 6 sq.mm. Cu
3 core, 2.5 sq.mm. Cu
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150mm dia RCC pipe
3)-EARTHING SYSTEM- Supply, installation, testing and commissioning of followings :- Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: 25 x 6 mm strip
6 SWG wire
D)-Plumbing -1-SANITARY FIXTURE & FITTINGS:- Supplying, Installation, Testing and Commissioning white vitreous china wall mounting water closet of approved shape including seat cover, and fittings, nuts, bolts and gasket etc complete including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning of twin flush concealed cistern with knob and frame and fittings, nuts, bolts and gasket etc complete including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning Table top wash basin with C.I. brackets with waste of standard pattern with waste fitting, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 480x300 mm.
Supplying, Installation, Testing and Commissioning C.P. Pillar cock with aerator including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning white vitreous battery based infrared sensor operated urinal of approx. size 360 x 330 x 740 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Supplying, Installation, Testing and Commissioning urinal partition of size 90x320x720 mm deep. including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning C.P. Bottle Trap including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning of surface mounted satin-finish type 304 stainless steel jumbo roll toilet tissue dispenser complete.
Providing, fixing, Testing and Commissioning of CP brass two way bib cock with wall flange including, necessary flange, cutting and making good he walls / floors wherever required complete.
Providing and fixing health faucet with 1 m ss braided hose pipe and swivel hook including all fittings complete.
Supplying, Installation, Testing and Commissioning bright polish stainless steel surface mounted dual coat hooks complete.
Supplying, Installation, Testing and Commissioning of Towel Ring fixed with CP brass screw complete.
Providing, fixing, Testing and Commissioning surface mounted soap dispenser with horizantal tank , corriosion resistant valve dispense and 1.2 litre capacity soap refill window including cutting and making good the wall wherever required.
Providing, fixing, Testing and Commissioning bib cock with wall flange and areator of approved quality colour and make including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning 5mm thick glass mirror including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning of Jet speed hand dryer, 1750 Watt Power, Auto turn off including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning C.P. angle cock with wall flange including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning polyamid connection pipe including cutting and making good the wall wherever required.
Supplying, Installation, Testing and Commissioning of Cruse set including EWC (European type water closet) size 710 X 370X 810mm with cistern, soft close seat cover, flush fittings, wash basin( 510 x 400mm ), lever arm faucet for ease of operation, 2 nos. wall mounted grab bar, 1 no. wall mounted hinged hand rail fixed to wall with brackets including cutting and making good the wall and floors as required. (IN SPECIAL NEEDS RANGE) (Divyang Toilet)
Supplying, Installation, Testing and Commissioning of classic series surface mounted sanitary bin with satin finish stainless steel.Door has key lock. Self-closing panel covers disposal opening.Removable,leak proof,4.5 L Plastic bin. including cutting and making good the wall wherever required. (in ladies toilet)
Supplying, Installation, Testing and Commissioning of surface mounted sanitary disposal bag dispenser with satin finish stainless steel. Equipped with concealed locking device. Concealed wall plate 0.8 mm (22-gauge) type 304 stainless steel. Hold one pack of 25 two ply plastic bags. including cutting and making good the wall wherever required. (in ladies toilet)
Supplying, Installation, Testing and Commissioning of surface mounted satin finish type 304 stainless steel, Trimline recessed paper towel dispanser,leak proof waste bin, hand dryer complete as required.
Supplying, Installation, Testing and Commissioning of Water cooler made of pure Stainless steel body, without rusting , without corrosion. including externallly mounted thermostat to make it easy to set water temperature, wth extra large SS wate tray prevent spalashing and ensures fast drainage of water , aoto cut facilitie , over load compressor protection, electricl supply internal wiring etc. to complete the work.
Providing, fixing, Testing and Commissioning automatic Aerosol Dispenser with wooden cleats and C.P. brass screws including cutting and making good the wall wherever required
2)- SOIL, WASTE & VENT 100 mm dia-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and bend of required degree with access door, insertion rubber washer 3mm thick , bolt and nut complete 100mm dia - Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing plain bend required degree 100 mm dia -Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing plain bend required degree 75 mm dia - Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing double equal plain junction of required degree 100x100x100x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
75x75x75x75mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing single equial plain junction of required degree 100x100x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
75x75x75mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing shielded coupling for hubless centrifugally cast iron pipe i-150mm dia - SS- 304 grade coupling with EPDM rubber gasket
100mm dia -SS- 304 grade coupling with EPDM rubber gasket
Providing and fixing single unequial plain junction of required degree 150x150x100mm-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling andfloor. (internal work). a)-32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
providing and Fixing trap of self cleansing design with screw down or hing grating with or without arm complete including cost of cutting and making good walls and floors 100 mm dia inlet and 100mm dia outlet-Hubless Centrifugally cast (Spun) iron pipes epoxy coated inside and outside IS:15905
Providing and fixing cast bronze cleanout plug brass screws, male threaded joint with G.I socket coupled to CI hubless pipe including jointing etc. complete in all respects. 100 mm dia
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32, 40 0r 50 mm size fabricated from 100 mm dia G.I. Pipes (Medium class)and welded G.I. Sockets, fixed to C.I. Trap with lead caulked joint and set in cement concrete as per standard drawing etc. complete in all respect.
Providing and fixing SS grating of approved quality and colour. Circular type 124 mm nominal dia with 25 mm waste hole.
3-RAIN WATER- Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 6 Kg / Sq.cm for drainage system cut to required length including all necessary fittings and specials such as bends, junction, offset, access pipe (plain or door) and vent cowl fixing wall / ceiling level supported by GI clamps, hangers, etc.. and making good the same complete as required. (For Rain Water).110mm diameter
Making Khurra 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C sheet 1m x 1m x 400 microm, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edage and making and finishing the outlet complete.
4-INTERNAL WATER SUPPLY-Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [Bl 20 mm. Internal work - Concealed Pipe a-15mm nominal outer dia. Pipes.
20mm nominal outer dia. Pipes.
25mm nominal outer dia. Pipes.
32mm nominal outer dia. Pipes.
40mm nominal outer dia. Pipes.
50mm nominal outer dia. Pipes.
Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(A) 15mm (upto 10 ton) (internal work). Internal work - Exposed on wall 15mm (a) nominal outer dia. Pipes.
20mm (B) nominal outer dia. Pipes.
25mm (C) nominal outer dia. Pipes.
32mm (D) nominal outer dia. Pipes.
40mm (E) nominal outer dia. Pipes.
50mm (F) nominal outer dia. Pipes.
Providing & fixing brass stop cock of approved quality . 15mmdia nominal bore
20mmdia nominal bore
Providing and fixing gunmetal gate valve with CI wheel of approved quality (Screwed end) a- 25mm nominal bore
20mm nominal bore
Providing & fixing Auto Air vent for water supply risers, suitable for pressure not less than 15 Kg/Sq.cm. 25 mm dia
5-SEWERAGE & DRAINAGE SYESTEM- Providing and laying (to level or slopes) and jointing with stiff mixture of Cement Mortar in proportion 1:1 Seit glazed stoneware pipes including testing of pipes and joints complete.150 mm (B) diameter (upto 10 ton)
Providing and laying Cement concrete 1:5:10 (1-Cement: 5-Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(B) 150mm dia. (166mm Ave. bed thickness) 150mm dia SW pipe (B)
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside} with standard weight.(i} Square mouth traps. 150x100 mm size P type (upto 10 ton}
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement: 3-coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and testing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of O.lM. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.150 mm diameter
Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (upto 10 ton)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid