Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest and reasonable bidder. | |
| 2 | L2₹10.3 L+₹76,307 (8.00%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than lowest bidder. | |
| 3 | Rejected-Technical | - | Rejected-Technical Not fulfil proper documents |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAL
GE AF NAL
AS DESCRIBED IN BILL OF QUANTITIES
2023_MES_633435_1
GE (AF) NAL/T-64/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
BIKANER SD UNDER GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF NAL
₹30,000
Yes
8 Mar 2024
19 Dec 2023
17 Jan 2024
19 Dec 2023
15 Jan 2024
2 Jan 2024
19 Dec 2023 - 30 Dec 2023
Amount
Rewinding to burnt transformer of voltage stabilizer 5 KVA with copper winding wire including varnishing with super quality varnish, suitable size of thimble, mica paper and testing after rewinding complete all as specified and directed.
S&F in repair of circuit plate of existing make and model suitable for 5 KVA voltage stabiliser complete all as specified and directed.
S&F in repair of the following items with existing make and model and provided with new and suitable for 5 KVA voltage stabiliser complete all as specified and directed :-
Time delay relay
Toggle switch
Auxiliary transformer 24 Volt
Step up relay
PVC connector base plate.
Attending the complaints pertaining to Summer appliances such as Split /window type Air Conditioners, Refrigerators, deep freezer, water coolers of any size/capacity lodged by users in person and reporting to the concerned JE E/M complete all as specified and as directed by Engineer-in-Charge. Note:- Any consumable items will be measured and paid seperately.
Supply and fixing inrepair PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 4.0 sqmm complete all as specified
M&L for shifting of split AC 1.5/ 2.0 TR with indoor and outdoor unit and refixing the same in new position and testing up to the satisfaction of Engr in charge complete all as specified.
Disconnection and taking out, reinstallation and connection of spilt AC of any capacity after carried out the following maintenance / servicing task :- (a) Cleaning of Air filter with vacuum cleaner(Pressurised air) & washing of the fins using pressurised water by portable pump for AC servicing. (b) Cleaning of complete AC unit by hand blower removing dust complete (For split AC indoor, out door unit) (c) Servicing blower motor complete. (d) Complete job for a particular AC shall be carried out on prompt basis and no part work shall be left for next day . (e) The Split AC before servicing would be covered with "closed type horizontal air conditioner wash bags" for insite servicing at critical locations.
S&F in repair copper condenser unit suitable for 2/1.5 Ton capacity split AC of existing make and model complete all as specified and directed
S&F in repair hermetically sealed unit compressor suitable for split/window type AC 1.5 Ton capacity of existing make and model complete all as specified and directed.
All as per Srl item No 9 here-in-before but for split/window type AC 2 Ton capacity.
Supply and Charging Refrigerant gas R-22 /410A/32 including cost of welding leak detection and refitting the same in entire system,for 1.5 ton and 2.0 ton window/split AC all as specified and as directed. Note : Cylinder for refrigerant gas shall be arranged by the contractor at his own cost.
Refrigerant gas R-22/ R-134A or suitable refrigerent including cost of welding, leak detection, rectification in the entire system , testing and commissioning of water coolers/refrigerator/deep freezer of any capacity all as specified and as directed. Note : Cylinder for refrigerant gas shall be arranged by the contractor at his own cost.
S&F in repair copper tube ½ inch bore incl insulation of AC pipe complete all as specified and directed.
S&F in repair copper tube 3/8 inch bore incl insulation of AC pipe complete all as specified and directed.
M&L for taking out condenser/ evaporator unit of split type Air Conditioner of any capacity and rectifiy leakage/ blockage of refrigerant and refixing the same after carryout necessary repairs/brazing work complete all as specified and directed.
Disconnection and taking out, reinstallation and connection of window AC of any capacity after carried out the following maintenance/servicing task :- (a) Cleaning of Air filter with vacuum cleaner(Pressurised air) & washing of the fins using pressurised water by portable pump for AC servicing. (b) Cleaning of complete AC unit by hand blower removing dust complete (c) Servicing blower motor complete.
S&F in repair condenser unit suitable for 2/1.5 Ton capacity window type AC of existing make and model complete all as specified and directed. Note : Labour for taking down and fixing shall deemed to be included in item.
S&F in repair of outdoor unit kit suitbale 3 star rated IDU with complete fittings like condenser assembly, fan motor, suitable for existing 1.5/2.0 ton capacity Split type Air conditioner complete all as specified and directed.
S&F voltage stabilizer of capacity 5 KVA for split AC 1.5/2.0 Ton capcaty complete all as specified and directed
Supply and fixing in repair UPVC conduit pipe 20mm dia to drain out pipe including all accessories and taking down the existing one, with fixing arrangment on wall, ceiling etc.,complete all as specified and directed.
S&F in repair to the following items with new of existing make and model suitable for Split/Window type AC 1.5/2 Ton capacity complete all as specified and directed :-
Blower Motor
Remote control
Starting relay
Over load relay
Thermo state switch
Starting Capacitor any capacity
Running Capacitor any capacity
Supply and fixing in repair Insulation for copper tube of split AC of capacity 1.5/2 ton complete all as directed.
Supply and fixing as in repairs PCB board for Window/ Split AC upto 2 Ton of any make and as per sample and as specified and directed.
Supply and fixing as in repairs window AC grill for Window AC upto 2 Ton of any make and as per sample and as specified and directed.
Supply and fixing in repair Condenser fan motor for window/ split AC 1.5/ 2.0 Ton capacity.
S&F in repair of indoor unit kit with complete fittings like copper coil, temperature display, blower motor, PCB etc suitable for existing 1.5/2.0 ton capacity Split type Air conditioner complete all as specified and directed.
S&F in repair hermetically sealed unit compressor suitable for refrigerator of 165 litre capacity of existing make and model complete all as specified and directed.
All as per Srl item No 23 here-in-before but for Refrigerator of 300/320 litre capacity.
All as per Srl item No 23 here-in-before but for Deep freezer of 300/320 litre capacity.
S&F in repair to the following items with new of existing make and model suitable for refrigerator 165/320 capacity complete all as specified and directed :-
Starting relay
Over load relay
Thermo state switch
Starting Capacitor suitable capacity
Running Capacitor suitable capacity
Vegetable Tray with glass cover.
Ice tray
Rubber door gasket magnetic type
Shelve PVC coated suitable
S&F in repair hermetical sealed unit compressor suitable for water cooler of 40/80 litre capacity of existing make and model complete all as specified and as directed.
All as per Srl item No 27 here-in-before but for water cooler of 60/120 litre capacity.
S&F in repair to the following items with new of existing make and model suitable for water cooler 40/60/80/120 ltrs capacity complete all as specified & directed :-
Starting relay
Over load relay
Thermo stat switch
Starting Capacitor suitable capacity
Running Capacitor suitable capacity
Taking down carefully ceiling fans of any sweep & make from fan hook and refixing in same position after necessary repairs / rewinding etc incl connecting up with flexible twin core cable 23/.0076 from ceiling rose or connector to fan complete all as specified and directed. Note :- repair item will be measured and paid seperately.
All as per Srl item No 30 here-in-before but exhaust fan/ pedestal/ air circulator fan of any sweep and make.
Rewinding of ceiling fan of sweep 1200mm, of any make & model, with supper enameled copper winding wire of same size as per old winding wire and confirming to relevant IS including replacement of insulation materials, varnishing, greasing & lubricating to ball bearings, GM bushes and testing etc complete all as specified and directed.
All as per Srl item No 32 here-in-before but ceiling fan 1400mm sweep
All as per Srl item No 32 here-in-before but exhaust fan of 230/300mm sweep
All as per Srl item No 32 here-in-before but exhaust fan of 450 sweep
All as per Srl item No 32 here-in-before but exhaust fan of 600 sweep
All as per item No 32 here-in-before but pedestal/air -circulator fans of any size
Supply only in repairs of ball bearing for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep, complete all as specified and directed. Make : SKF/NBC of size 6201 to 6204
Supply only in repairs of GM bush for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed
Supply only in repairs of Stainless steel shaft for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed.
Supply only in repairs of capacitor 2.5/3.15 mfd for ceiling /cabin fan/ table fan of any sweep and complete all as specified. Make : USHA /ASIAN /RENTROL
Supply only in repairs of capacitor 4 mfd for Exhaust fan of any sweep and complete all as specified and directed. Make : USHA /ASIAN /RENTROL
Supply only in repairs of rubber seal for ceiling fan complete all as specified and directed.
Supply only in repairs of mild steel U-clamp including 10mm dia bolt, nut, washer and split pin for ceiling fan completed all as specified and directed.
Taking down carefully old U/s sub main wiring of any type /size including conduit and conduit accessories and making good the disturbed surfaces all as directed.
M/L for submain wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable of 4.0sqmm and 4.0 Sqmm as earth lead through surface PVC conduit complete with conduit and conduit accessories not less than 20mm dia all as directed.
Supply and fixing single pole and neutral sheet metal enclosure with socket plug top 2 pin and earth complete with one single pole MCB 20 Amps all as directed.
Taking up / down water heater (Geyser) of capacity 25 ltrs/ 50 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection, and including transportation to the contractor 's workshop for repair and vice - versa, , and after repairing,general cleaning with suitable detergent and making fully serviceable and fixing back. in same location / position or new location all as directed. Note :- (a) Replacement of any un-serviceable parts required for making the geyser serviceable will be measured and paid seperatelly under "supply only".
Supply only stailnless steel inner tank suitable for 25 Ltrs geyser of any make /shape with any number of holes for fixing geyser assembly.
All as per item No 49 herein before but for 50 ltrs.
Supply only bottom base assembly of stainless steel 6/8/9 holes type suitable for 25 ltrs capacity geyser all as directed.
All as per item No 51 here-in- before but for 50 ltrs capacity geyser .
Supply only heating element 1000/1500/2000 watts capacity of any shape /type with rubber gasket ISI Marked. Make :- willson , ditz, Dass pass
Supply only thermostat suitable to adjust the temperature from 0º C to 80º C all as directed ISI Marked. Make :- ABC, Ditz, Arcon , Dass Pass
Supply only neon indicator lamp of any shape / size / colour all as directed.
Supply and fixing in repair rubber gasket of thickness 5 mm for geyser assembly of 06/08/09 holes all as specified.
Supply only the bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape all as directed.
Supply only 3 pin plug top 15 Amps, back plate bakelite suitable for 230/240 volts AC supply all as directed.
S&F in repair rubber ring of existing size to the lower and upper housing of geyser, any make / size all as directed.
Supply only outer MS shell complete inluding top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG all as directed.
All as per item No 60 herein before but for 50 ltrs.
Supply and fixing in repair angle stop valve , chromium plated , brass fancy type screwed down,high pressure with crutch or butterfly handle screwed down,screwed for iron pipe or for union, suitable for 15 mm bore pipe , complete all as specified and directed
Supply and fixing in repair Bip cock without flange (foam flow) , cast copper alloy chromium plated , fancy type , screwed for iron pipe or for union , suitable for 15 mm bore pipe , complete all as specified and directed.
supply and fixing in repair PVC connection 15mm bore 450mm long in any position with both end brass nut with inner threading and washer suitable for cold water connection complete all as directed .
All as Srl item No.64 above but for hot water connection.
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .