Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC quoted lowest rate | |
| 2 | L2₹45.3 L+₹1.9 L (4.29%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Rejected-Finance quoted high rate | |
| 3 | L3₹47.0 L+₹3.5 L (8.09%)Rejected-Finance | L3 | Rejected-Finance quoted high rate | |
| 4 | Rejected-Technical S O KALA RAM C O LALIT AND BROTHERS UTARLAI UTTARLAI VPO UTTARLAI BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | - | Rejected-Technical REJECTED |
Tender Value
₹43.9 L
EMD Value
₹88,000
Closing Date
13 Sept 2024, 6:00 pmClosed
CWE AF JAISALMER
HQ CWE AF JAISALMER
SPECIAL REPAIR OF E/M APPLIANCES LIKE VCB, SERVO VOLTAGE STABILIZER, MOTOR AND PUMP AT AF STN UTARLAI
2024_MES_667172_1
80315
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) UTARLAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UTARLAI
₹88,000
Yes
17 Oct 2024
22 Jul 2024
14 Sept 2024
22 Jul 2024
13 Sept 2024
6 Aug 2024
Amount
Excavating in trenches in any type of soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, cesspits,manholes, pier holes, water/sewer pipe line, electric cable line etc not exceeding 10 Sqm area on plan and not exceeding 1.5 m in depth and getting out ,including taking out defective cable, sand cushion and protection cover and stacking serviceable materials for reuse and removing unserviceable from complete all as specified and directed.
Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed. (Note:-23 cm Punned thickness shall be reckoned for the purpose of measuremet and payment)
Supply, lay, test, joint and commission in replacement XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 95 sqmm 3 core, 11000 Volts grade (11 KV earthed system); laid in trenches/under floor/through ducts, fixed on pole/pipes/open complete all as specified and directed. Note : Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ
S&F Cable End Termination Jointing Kit, HT 11 KV grade, heat shrinkable, indoor type complete with jointing materials and accessories suitable for HT XLPE cable 3 core 11 KV grade of size 70 Sqmm to 120 Sqmm x 3 core armoured alumuinium conductor cable complete all as specified and directed. Note- Unit rate quoted by the contractor shall be deemed to inclusive of jointing material like long sleeve form RMU connection and other connected items, T&P and labour etc.
Supply and lay 300mm x 180mm x 40mm thickness Un-reinforced Precast Concrete Cable Covers Class HV, type-1, flat, ISI marked, putting on the cable abutting to each other for cable protection complete all as specified and directed.
M&L for Earthing in replacement complete with Copper earth plate electrode 60cm x60cm x 3.15mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level ,connected to and including Copper earth strip 20X3mm by means of nut, bolts, check nuts and washers made of copper alloy and connection to test point and earth dolly and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil/rock strata and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I complete with the following:- (a) Excavation and earth work for drilling hole for electrode in any type of Soil/rock strata. (b) PCC chamber in cement concrete 1:3:6 type C-1, Pre-cast RCC cover with CI frame with suitable handle 50 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with 20 mm bore galvanised iron medium grade watering pipe and lugs etc complete all as specified and directed. (d) 40 mm bore galvanised iron light grade protection pipe for protection of earthing lead and earth lead, each 7.5m long complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. Note:- Copper earth strip and 40mm light grade GI protection pipe upto 7.5m each shall be deemed to be included in quoted rate of this item. (ii) If the desire earth resisitance not obtained on testing after completion, earthing shall be redone by the contractor without any extra cost upto obtain the desired resistance. (iii) Tibba sand shall be shall be used by the contractor after filling of salt and charcoal for earthing.
Supply, install, commission and test Ring Main Unit (RMU) HT 11 KV Outdoor Extensible type, cubical 3 Way (1 I/C VCB + 2 O/G VCB) gas (SF6) insulated comprising with incomer - 1 Nos. X VCB and outgoing - 02 NOs X VCB of rating of each 630 Amp 3 phase 50 cycle 12 KV, 20 KA/3 sec ambeint temprature (-5 degree celsius to +55 degree celsius ) . Manual operated SF6 breaker having copper bus bar 600 Amp rating cast resin tank with , LV current transformer compatible with self powered relay & 11 KV resin cast PTs (one set of 3 Nos.) with seprate metering chamber complete make- SIEMENS model 8 DJH ST/ euivalent in makes specified in Appendix "B" Makes of Particular Specifications.. Each Circuit breaker will have the following- (i) Manually operated SF6 VCB 3 phase 630 A, 12 KV rating circuit breaker having resin cast tank and earthing switch with full making capacity with position ON-OFF - Earth (ii) Manual line disconnector with three position switches ON-OFF -Earth (iii) Anti reflex operating handle (iv) Auxiliary switches 3 No. +3 NC with wiring
Accessories with each RMU includes- (i) Operating handle -01 Nos (ii) Right angled cable boots make- Siemens/equivalent - 03 Sets (iii) Capacitive voltage indicator type HR-ST-Make Hortsmann - 03 Nos separate metering chamber having - (i) 3 phase 3 limb drawout type bus connected epoxy potential transformer ratio 11 kv/root3/110V/root 3 AC accuracy 1.0 burdon 50 VA-01 9ii) Digital type voltmeter -01 Nos. (iii) RYB indicator- Sets NOTE- (i) RMU shall be outdoor plinth mounted (ii) Erection commissioning and civil work (plinth protection) for RMU is deemed to be included with unit rates. The plinth protection details as per the manufacturer instruction after approval of drawing from GE.(i) Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease for installation/testing /*replacement purposr) with door arrangement for enhanced safety (IP 54+IP3X) interlocke to prevent access up to 11 KV, 185 Sqmm 3 core alongwith XLPE AL cable termination each set of 03
(iii) Right angle boots (push on type) each set of 3 (iv) 3O/C +1 E/F self powered numerical protection relay with low and high set for overcurrent and earth fault. relay should have facilities to display maximium loaded phase current also. relay shall record minimum 5 fault records with time stamping . Relay shall be communicable with RS 485 port on MODBUS protocol-01 No. /per VCB (v) Relay for OTI/WTI/B - relay protection-01 No. (vi) Associated ring core cast -resin insulated CTs 50/1 Amps 2.5 VA 10 P 10 protection - each set of 3 (vii) Arc proof cable cover having cable entry from bottom , front with interlocking mechanism including earth switch -01 No. (viii) Capacitive voltage indication fixed type system as per IEC 6123 with LED -01 set (ix) ON OFF Earth mechanical indication on the front mimic of the panel - 01 No. (x) Emergency trip push button -01 Nos.
01 No bus connected fixed- type auxilary transformer with floor mounted compartment of matching height and depth positioned alongside RMU to provide required aux supply for spring charging motor and metering consisting of following accessories. (i) 3 ph ( 11 KV/root 3) ; 230 volt AC 500 VA auxilary transformer -01 No. alongwith trivector meter 2X12 Volt DC battery -01 Set (iii) Battery charger with power pack -01 No. with indication of status of functioning (iv) HRC fuses links for primary side isolation and AC/DC supply availability -01 Set (vi) anti condensation space-heater -01No. (vii) CFL lamp for illumination and 3 pin socket with switch-01 No. (viii) Enclosure- powder coated camouflage (ix) Complete RMU must be scada compatible (x) Separat cable entry box must be mounted with RMU system(D) Standard mano meter -01 for each tank operating handle -2 , cable clamping provision (standard) -01 / for every cable entry operation and maintenance manual-01, installation and commissioning manual-01, Foundation as per OEM recommendation (earth work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted . Height of plinth should not be less than 0.60 mtrs from ground level.
NOTE- (a) The above module consisting of VCBs shallbe alligned appropriately and must have electrical and mechanical interlocking as per the latest electrical and mechanical interlocking as per latest electrical safety norms including installation on plateform as recommended by OEM complete. Following T&P alonwith RMU will be supplied and cost of the same deemed to be included in quoted rates (i) Rubber hand gloves-11 KV -02 Pair of gloves (ii) Multipurpose screw driver set -02 Set of all size (iii) Plier-02 Nos (iv) Charging handle for RMU-02 Nos
Supply install, test commission Servo Controlled Voltage Stabilizer (Conforming to BIS 9815 Part-I 1994), ( second revision) (Re-affirmed 2019) . The performance requirement should be as per para 9 of the BIS 9815 ( Part -I) ( Re-affirmed 2019) Capacity- 50 KVA three phase 50 Hz, Naturally oil cooled, indoor, unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos, digital display type relay free smooth and silent operation with 1st filing of Transformer oil up to level having following specification :- (a) Input Voltage 340V-480V (b) Output Voltage stabilizer at any deigned/ desired voltage 415V (+/-)1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e) Response time not to exceed 20 mile second. (f) Sensitivity (+-) 1% (g) Rate correction 8 Volt/ second for single phase and 3 v/seconds for phase to phase. (h) Efficiency more than 95% (j) Type of load three phase, unbalanced type. (k) Digital display Voltmeter/ Ammeter Note- By pass arrangement for servo stabilizer shall be deemed to be included in quoted rates.
Rasam Engg Co. (BID ID -3084328)
RISING ELECTRICALS (BID ID -3094096)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .