Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC Reasonable |
| 2 | L2₹1.6 Cr+₹4.6 L (2.92%)Rejected-Finance | ₹1.6 Cr+₹4.6 L (2.92%) | L2 | Rejected-Finance Rates quoted on higher side |
| 3 | L3₹1.9 Cr+₹36.6 L (23.3%)Rejected-Finance | ₹1.9 Cr+₹36.6 L (23.3%) | L3 | Rejected-Finance Rates quoted on higher side |
| 4 | Rejected-Technical | - | - | Rejected-Technical Does not fulfill the criteria as laid down in the NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in Cat. b (ii) |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
2 Jan 2020, 6:00 pmClosed
CWE AF PANAGARH
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
PROVISION OF WORK SERVICES FOR INDUCTION OF TRANSPORTABLE SRE AT AIRFORCE STATION PANAGARH
2019_MES_276120_1
82263/PAN/E8
Open Tender
Miscellaneous Works
Lump-sum
365 days
GE AF PANAGARH
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE AF PANAGARH
₹2.2 L
Yes
5 Feb 2020
9 Nov 2019
4 Jan 2020
9 Nov 2019
2 Jan 2020
14 Dec 2019
9 Nov 2019 - 6 Dec 2019
Amount
SCHEDULE 'A' PART-I (BUILDING WORK) Total Amount of Sch 'A' Part-I (Buildings/Structures) Prepriced amount B/F from Sl page No. 19.
Total Amount of Sch 'A' Part-II (INTERNAL WATER SUPPLY) Prepriced amount B/F from Sl page No. 20(R )
Total Amount of Sch 'A' Part-III (INTERNAL ELECTRIFICATION) Prepriced amount B/F from Sl page No. 22R
Total Amount of Sch 'A' Part-IV (SEWAGE DISPOSAL) Prepriced amount B/F from Sl page No. 25R
Total Amount of Sch 'A' Part-V (ROAD & PATH) Prepriced amount B/F from Sl page No. 27R
Total Amount of Sch 'A' Part-VI (CHAINLINK FENCING & GATE) Prepriced amount B/F from Sl page No. 31R
Total Amount of Sch 'A' Part-VII (EXTERNAL WATER SUPPLY) Prepriced amount B/F from Sl page No. 33R
Total Amount of Sch 'A' Part-VIII (EXTERNAL ELECTRIFICATION WORKS) Prepriced amount B/F from Sl page No. 35R
Sch 'A' Part-IX (MISCELLANEOUS ITEMS OF WORK) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.6 signifies this fact only.
Supply and fix wall mounted LED batten with 18 W LED 6500 K tube both side connection, box type complete all as specified. (Make : Havells/Philips/Wipro/Crompton Greaves/Surya/ M/s Century LED Ltd)
Supply and fixing LED 10 Watt wall lamp complete all as specified and as directed.
Supply & fixing /hanging ceiling fan, BEE 5 star rated,1200 mm sweep size, 230 volts, AC, 50 Hz, single phase, including provisioning of cord flexible copper 3 core of size 23/ 0.0076 of required length not exceeding 1.5 metre from ceiling rose or connector to ceiling fan for giving electric connection complete all as specified and directed by Engineer-in-Charge.
Supply & fixing exhaust fan with louver shutter, turbo force, 225 mm sweep size or dia., 1400 RPM, BEE 4 star rated suitable for operation on 240 volts, AC, 50 Hz, single phase electric supply with necessary bolts (6 inches long, 6 mm dia.) with nuts and washers for fixing the fan in wall including making necessary electric connection from ceiling rose to the fan with PVC insulated flexible cord copper of size 0.75 sqmm complete all as specified and directed.(Make: Havells, Model Ventil Air-Dx or its equivalent model in Crompton Greaves/Khaitan/Bajaj/Orient)
S&F sheet metal enclosure for MCB distribution board , powder coated, double door, TPN , Vertical type for incoming MCCB , 04 way, with 200 Amp rated bus-bar, 415 volts, AC, flush mounting type including grouting on the wall by means of screws and rawl plugs and making good disturbed surfaces to match with existing colour of wall complete all as specified. Note: Rate of MCCB paid in respective item
S&F sheet metal enclosure for MCB distribution board, powder coated, double door, SPN , 06 way, with 200 Amp rated bus-bar, 240 volts, AC, flush mounting type including grouting on the wall by means of screws and rawl plugs and making good disturbed surfaces to match with existing colour of wall complete all as specified.
S&F sheet metal enclosure for MCB DB, powder coated, double door, SPN , 04 way, with 200 Amp rated bus-bar, 240 volts, AC, flush mounting type including grouting on the wall by means of screws and rawl plugs and making good disturbed surfaces to match with existing colour of wall complete all as specified.
S&F MCB, SPN with Fault indicator 240 volts, AC,50 Hz, 6-32 Amps rating, 'C' curve characteristics,10 kA breaking capacity all as specified.
S&F MCB, Four Pole with Fault indicator 415 volts, AC,50 Hz 40 Amps rating, 'C' curve characteristics, 10 kA breaking capacity all as specified.
S&F MCB, Single Pole with Fault indicator 240 volts, AC,50 Hz, 6-32 Amps rating, 'C' curve characteristics, 10 kA breaking capacity all as specified.
Supply and fix metal earth plug and socket 20 Amp, 3 Pin 3 Pole having 3 modules, flush mounting suitable for Air-condition supply,240 volts, AC, 50 Hz complete all as specified and as directed .
S&F LED luminaire 1 x 45/40 watt for building security lighting purpose with pressure die cast aluminium housing with all accessories , IP 65 protection, internally prewired and including and connecting with twin core twisted flexible cord of 0.75 sqmm copper conductor cable from ceiling rose to the fitting, including all other necessary fixing accessories such as clamps, nut, bolts and GI pipe (medium grade) 40mm dia bracket arm for fixing the fitting to wall of building complete all as specified & directed. (Make : Havells / equivalent model of Philips/Crompton/Surya/ Eveready /M/s Century LED Ltd)
Material & labour providing 10 users septic tank, Hume pipe including all necessary excavation & earth work, PCC foundation & RCC (M-25) slab etc complete all as specified and as shown on drawing(s).
Material & labour providing 1.2m dia & 3.00m deep Soakage well including all necessary excavation & earth work, PCC foundation, honeycomb walling,PCC band, RCC (M-25) cover slab, brick bat filling etc. complete all as specified and and as shown on drawing(s).
Supply and install, testing and commissioning HT 11 KV indoor type, floor mounted, 3 Phase 50 Hz, 400 Amps Vaccum Circuit Breaker, Incommer Panel, having rupturing capacity of 250 MVA, totally enclosed metal clad switchgear, flush front horizontal draw out and horizontal isolation having 'M2' class type tested mechanism, effective earthed supply system comprising of housing breakers, mechnical interlocks, safety sutters, 06 Nos isolating plugs and a VCB trolly three vaccum interupter & epoxy supports,insolators and self aligning finger type isolating contacts, Trunks having integral locking in device for insertion and withdrawal of VCB complete with necessary interlocks. Manual charged independend spring closed/spring tripping, trip free operating mechanism with manual closing and tripping push button, mechanical indication viz. Breaker closed/open, spring charged/Discharged mechanical opertion counter, electrical release coil, breaker operating auxiliary switch with 6NO+6NC and spare contacts and Motorised mechanism plus manual hand operting mechanism. ircuit breaker shall have arc protection system for all three compartments viz. , busbar and cable. The switch board panel shall be sheet steel encloser of minimum 2mm thick with protection class IP4X , E47, epoxy insulated with one bus PT. The panel shall be electrically operated trip free for 400Amp TP VCB with mechanical ON & OFF indicators and spring charged motor, shunt tripping & closing coil arrangement suitable for 110V DC power pack. The DC power of 110V to be included. The VCB panel shall be confirming to IEC 62271-100 & IEC 62271-200. The panel inclding following accessary & specification comprising complete all as specified and as directed:-
Supply and fix Voltage Stabilizer for automatic operation ,3 Phase, naturally oil cooled,indoor type & designed for input variation between 300V to 480 V with out put voltage stabilized at 415 Volts with accuracy +- 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA. (Make: VINTEC/VOLINA/APLAB/VOLTAMP /ANDREW YULE/ BRENTFORD/ M/s Instruments & Equipments Co.)
Supply, Installation, testing and commissioning of Isolation transformer 100 KVA,3 Phase,Oil Cooled including first fill up oil of requisite dielectric strength, Floor Mounted, Metalic Body, Unbalance Type, Winding - Copper (Primary- 415 V 3 wire 50 Hz Delta, Secodary 415 V 4 wire Star) ,designed for input voltage of 415 Volt ± 5%, out put voltage 415 volt ± 5% , Input frequency 50Hz ± 3%,Vector Gp-DYN-11, Die Electric Strength- 2.5 KV for 60 seconds, Class of insulation-H, IR Value > 2000 Mega Ohms, Impendance Voltage- 3-4%, Properly enclosed complete all as specified and as directed by Engr-in-Charge. (Make: VINITEK/VOLINA/APLAB/VOLTAMP/ANDREW YULE / M/s Instruments & Equipments Co.)
M & L earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr deep connected with and including copper strip 20 x 3 mm upto 7.5 mtr length distance in 40 mm dia pipe light grade by means of nuts bolts washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and PCC cover and watering pipe 20 mm dia medium grade with funnel and necessary excavation complete all as specified.
Supply, installation, testing and commissioning of transformer step down, outdoor type, floor mounted, 11.00/0.433 KV, capacity 100 KVA, AC, 50 Hz, 3 phase, percentage of impendance 5% conforming to IS: 1180/2014 (Level-II) 1997, oil cooled including on load changing tap arrangement up to ± 10% in steps of ±1.25% as per the following description( Make: ANDREW YULE & CO/HINDUSTAN/ ITE GURGAON/ NGEF/ABB/SIEMENS/ VOLTAMP/CROMTON GREAVES) :- (a) Connection - DYN 11 (b) Cooling - ONAN (c) Winding - Copper, HT side Delta connection, LT side Star connection 3 phase 4 wire (d) Oil conservation tank with air release valve, explosion vent, oil level indicator, breather with Silica gel (e) Oil inlet and outlet pipe with gun metal valve and drain pipe (f) First fill up oil of requisite dielectric strength (g) Air release plug All tests shall be carried out according to 1180/2014 (Level-II) . The Contractor shall furnish original paid voucher and test certificate of the CRGO manufacturer. Prior to manufacturing the general arrangement, drawing and design details of the transformer shall be aproved by the accepting officer. (Note : PCC Platform as per manufacturer specification and drawing shall be provided and the cost of which shall be deemed to be included in the quoted rates)
M&L Chemical earthing (Compound Based earthing) having advance encapsulated compound based CPRI tested maintainance free , pipe in -pipe technology upgraded( Zinc and alloy coated), Zinc cozted (80-100) microns with pure zinc (99.9%) & alloy coating (200-250 microns). Earthing system confirming to IS 3034. The outer and inner pipe should be 76.2mm & 41.9 mm dia, 3 metre length, Zinc coated with additional special alloy coating 300 mm on the top side for additional protection of the terminal. The annular space between the pipes being filled up with compact fill (CF) (Crystalline conductive compound) . The compact fill (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when oter pipes corrodes. The inner pipe should be extended with terminals for connectivity. The job includes digging the pit not less than 3 metre and refilling the same by electrodite/conductolite Back fill compound(Ground Enhancer)CONDUCTOLITE, The BFC should be eco friendly , It should not contain environmentally hazardous material/metalhaving ROHS certification from NABL acrredited lab . The Earth pit should be provided with FRP earth pit cover for protection and safe guard of terminals.compete all as specified and directed by Engr in charge. Make- ASHLOK, MODEL-ASEEL-39- ZC & AC (76.3 mm Dia) 3 M LENGTH with back fill compound/ ABB or its equivalent make. Notes for Item No. 9.21 :- (i) In areas where soil condition is bad, good earth is to be filled in the exacavated pits by mixing the same with BFC 2 or 4 bags extra per pit/unit. (ii)The earthing values obtained shall be less than 1 ohm iii)The manufacturer shall provide minimum 10 years warranty on each earth pit in terms of ohmic value (iv) Extra BFC bag shall be measured and paid seperately. (v) The excavation, removing exacavated material paid seprately in respective item.
Supply & Fix on-load Change over Switch of 200 Amp, 415 V,AC, 4 pole in sheet metal enclosure powder coated complete all as specified and directed. (Make: Havells/Standard/Bentec/ABB/L&T)
Supply,laying and testing PVC insulated, PVCsheathed electric power cables (heavy duty) with stranded copper conductor ,armourmed, 1100 volts grade ofcross-sectional area 50 sq mm 3.5 Core complete all as specified and directed.
Supply,laying and testing PVC insulated, PVC sheathed electric power cables (heavy duty) with stranded copper conductor ,armourmed, 1100 volts grade ofcross-sectional area 25 sq mm 3.5 Core complete all as specified and directed.
Supply only Back Fill Compound (BFC) CONDUCTOLITE , 25 kg to a Bag complete all as specified and as directed.
Boring of hole under road, pavement, hard standing by incorporating trenchless technology using ultrasounding techniques complete with all necessary machine, T&P, tools and tackles including M&L providing HDPE pipes, 150 mm bore size , class PN 10, laid under road, pavement, hardstanding for passing cables complete all as specified and directed by Engineer-in-Charge.
Supply , Installation , commissioning and testing hi-wall split inverter air conditioner (outdoor & indoor unit), electric driven, single phase, AC, 220 volts complete with cordless remote control unit and with in-built air ioniser and plasma filter for better indoor quality with R410A refrigerant, minimum 3 star rating and EER 3.2 of capacity 2.0TR complete all as specified and directed by the Engineer-in-Charge. (Make: Voltas/Blue Star/Carrier/Hitachi/Diakin) . (Notes: Cost of angle iron bracket for mounting outdoor unit cost of copper tube shall be deemed to be included in the unit rate)
Supply, installation, commissioning & testing of water cooler, partiallly stainless steel body, electric driven, single phase having 80 litres storage capacity and 40 litres/hour nominal cooling capacity complete all as specified and directed by Engineer-in-Charge. (Make: Voltas/Blue Star/Trane/Carrier/Usha)
Supply and fixing voltage stabilizer for automatic operation, single phase naturally aircooled, indoor type and designed for input variation between 170 V to 250 V with out-put voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5 KVA complete all as specified and as directed.(Make: Voltamp/Aplab/Andrew Yule/Microtek/VINITEC/ / M/s Instruments & Equipments Co.))
Supply and fixing voltage stabilizer for automatic operation, single phase naturally aircooled, indoor type and designed for input variation between 170 V to 250 V with out-put voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 1.0 KVA complete all as specified and as directed.
Supply and fixing Sheet metal enclosure for MCB distribution board, powder coated, double door, SPN 8 way with 200 Amp rated bus bar, 240 Volts AC flush mounting type including grouting on the wall by means of screws and wall plugs and making good disturbed surface to match with existing colour of wall complete all as specified and as directed.
M/s KUMAR BUILDERS
FRIENDS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .