Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | ₹2.6 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹3.1 Cr+₹50.1 L (18.9%)Rejected-Finance | ₹3.1 Cr+₹50.1 L (18.9%) | L2 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
24 Jan 2023, 6:00 pmClosed
Chief Engineer Leh Zone
Chief Engineer Leh Zone c/ o 56 APO Leh 901 205
PROVISION OF FIRE STATION INCLUDING GARRAGE FOR TFF AND LIVING ACCN FOR FIRE CREW WITH ALLIED INFRA INSIDE DEPOT AREA OF 41 FAD UNDER GE I P NO 2 LEH
2022_MES_547320_1
180081 E8
Open Tender
Civil Works
Lump-sum
700 days
LEH
Please refer tender documents
8 documents required · 8 mandatory
₹2,000
GE (I) (P) NO. 2 LEH
₹3.8 L
Yes
1 Apr 2023
24 Aug 2022
1 Feb 2023
24 Aug 2022
24 Jan 2023
10 Jan 2023
Amount
NOTE: Schedule ‘A’ Part - I to VIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col- 6 only.
Total amount of Sch 'A' Part - I (BUILDINGS)
Total amount of Sch 'A' Part - II (INTERNAL WATER SUPPLY)
Total amount of Sch ‘A’ Part - III ( INTERNAL ELECTRIFICATION)
Total amount of Sch ‘A’ Part - IV (ROAD, PATH, CULVERT AND HARDSTANDING)
Total amount of Sch ‘A’ Part - V (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part-VI (EXTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' Part-VII (SEWAGE DISPOSAL)
Total amount of Sch 'A' Part-VIII (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
SCHEDULE 'A' Part - IX (MISCELLANEOUS B/R & E/M WORKS) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
S&F LED Lamp 09 Watt for holder type, confirming to Cat Pt No LHLDEUEEMC8R009 of Havells or equivalent make complete all as specified and directed.
S&F Vertical TPN Loadline distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 32 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and as directed.
S & F MCB, Single pole, 6 to 32 Amps, 10 KA complete all as specified and as directed.
S & F MCB, Single pole and neutral 32 Amps, 10 KA complete all as specified and as directed.
S & F MCB, triple pole and neutral 10 to 32 Amps, 10 KA complete all as specified and as directed.
Supply, installation, commissioning and testing of Monoblock pumping set having discharge 5 LPM at 30 mtr head complete with suitable capacity of electric induction motor 415 Volts, 3 phase, 50 Hz, including suction & delivery connection complete including DOL starter with enclousure and all accessories fixing on wall with all necessary arrangements complete all as specified and as directed. Note :- Out of the total qty, 01 shall be working and 01 shall be in standby configuration.
M&L for Construction of PCC solid block masonary valve pit of size 0.9X0.9X1.8m (internal dimensions) including excavation and earth work in any type of soil, PCC 1:4:8 type D-2 in foundation, block work in CM 1:4, 15mm thick plastering in CM 1:4 internally and externally, angle iron frame 40X40X6mm, with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle all as directed.
Supply and fix CI Foot Valve conforming to IS 4038, 50 mm (2”) dia.
Supply and fixing insulation on tubing of 25 mm dia pipe with 13mm thick nitrile rubber complete all as specified and directed.
Supply and fixing insulation on tubing of 50 mm dia pipe with 13mm thick nitrile rubber complete all as specified and directed.
Supply and fixing Aluminium Cladding of 28 SWG thickness on pipe 25 mm dia with 13mm thick nitrile rubber complete all as specified and directed.
Supply and fixing Aluminium Cladding of 28SWG thickness on pipe 50 mm dia with 13mm thick nitrile rubber complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,3 core, 1100 Volts grade laid in trench, duct, fitted on wall etc all as specified and directed. Note :- Cost of connection accessories req like copper lugs, glands etc shall deemed to be included in costed quoted rate.
Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity 315 KVA, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping + 5% to -10% of HV in steps of 2.5% each hand operated, off load tap changing gear including first filling of new transformer oil of dielectric strength not less than 50 KV with standard fittings such as two earthing terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, name rating and diagram plate, plain breather device to prevent ingress of rain water and inserts, drain Cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof and having 02 No under base channel and 04 No wheels. Note :- (1) Transformer shall be conforming to requirements of IS:1180 (Part-I) of 2014 (2) Transformer oil shall be conforming to requirements of IS:335 of 1993 specification for new insulating oil for transformers. (3) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between (-)35˚C to (+)35˚ C
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Main Fire Station)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 100 Amps. (b) MCCB 40 Amps, 415 Volt, 16 KA, 4 Pole- 01 No for incoming (c) MCCB 32 Amps, 415 Volt, 16 KA, 4 Pole - 01 No (Main F/S bldg) (d) MCB TPN 10 Amps, 415 Volt, 10 KA - 02 Nos (Repair Bay & 01 x standby) (e) MCB SPN 6 Amps, 240 Volt, 6 KA - 01 No ( 03 TFF) (f) Indicator Lamp LED type (RYB) - 01 Set
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Sub Fire Station)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 500 Amps. (b) MCCB 315 Amps, 415 Volt, 36 KA, 4 Pole- 01 No for incoming (c) MCCB 250 Amps, 415 Volt, 25 KA, 4 Pole- 01 No (Existing 08x ESH sheds) (d) MCB TPN 16 Amps, 415 Volt, 10 KA - 01No (Sub F/S bldg ) (e) MCB TPN 10 Amps, 415 Volt, 10 KA - 01 No (standby) (f) MCB SPN 6 Amps, 240 Volt, 6 KA - 01 No ( 02 TFF)
S & F precast PCC 1:2:4 type B-2, Cable route indicator of size 15 cm x 15cm x 75 cm in dimensions with projection of 45cm above ground level and 30cm grouted in PCC 1:3:6 type C-2 foundation, the exposed surface shall be painted with brown colour above ground and HT 11000 Volt/ LT 1100 Volt marked in red colour all as specified and directed.
Supplying 1000 Ltr capacity PUF insulated water storage tanks 3 layered having outer layer of FRP, middle layer of polyurethane foam 75mm thick and inner layer of HDPE (cylindrical vertical with closed top) all as specified.
DES RAJ CONTRACTS PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .