Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹48.4 L+₹1.7 L (3.61%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.9 L+₹3.2 L (6.79%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹50.1 L+₹3.4 L (7.28%)Rejected-Finance B4 60 1 NEW SANTOSHPUR THANDER PARA STATION ROAD 24 PARGANAS SOUTH PIN 700142 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 700142 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.4 L+₹3.7 L (7.94%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.6 L
EMD Value
₹87,120
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN ALTN TO BLDG NO 0 2 NEAR DALHOUSIE BARRACK AND IMPROVEMENT IN 04 ROOMS OF OFFRS IN OFFRS MESS OF CERTAIN UNIT INSIDE FORT WILLIAM UNDER GE(FW) KOLKATA
2022_MES_545482_2
8886/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹87,120
20 Oct 2022
9 Sept 2022
20 Sept 2022
9 Sept 2022
19 Sept 2022
9 Sept 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris outside MOD area and disposing off as per municipal guidelines complete all as specified and as directed. (NOTE: Quoted rate shall be inclusive of the cost of dismantling of air termination rod and earthing strips before removing the existing roof treatment and re-fixing the same after completion of water proofing treatment with PCC blocks, saddles, insulators etc as per existing layout. No claim in this regard shall be admissble during currency of work)
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for brushing neat cement slurry with 2.75 Kg of cement per Sqm on roof complete all as specified and directed.
M&L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L bituminous gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces, all as specified and directed.
M&L for Providing Cement Concrete, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding mixed with water proofing compound and the concrete surfaces is to be finished even and fair (without using extra cement) complete all as specified and directed. (NOTE: WPC Shall be measured & paid separately)
M&L 15 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm and allowing to dry till tack free. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Providing a layer of 150 GSM non-woven geo textile of approved make and laid over the APP membrane. (iv) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & prtect the seal with a polysulphide/polyurethane sealant.
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane. (v) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
S&F heat resistant roof/terrace ceramic tiles, of size 300 mm X 300 mm of minimum 9.5 mm thickness, white coloured with mineral composition for reflective thermal insulation with solar reflective index (SRI) > 0.90 on roof/terrace, laid over and including 20 mm thick screed bed in cement mortar 1:4 mixed with liquid water proofing compound @ 200 ml/50 kg bag of cement, applying cement slurry and scratching the screed bed for proper fixing of tiles, laying the tiles with 4-6 mm spacers, curing the tiles for 48 hours and subsequently filling and grouting the joints with mix of white cement & marble powder/grout powder in the ratio 1:1 including providing skirting upto 150 mm height along the parapet walls in the same manner but at an angle of 45 degree over screed bed in cement mortar 1:3 complete all as specified and as directed. (MAKE: JOHNSON, Model: Endura Cool Roof tiles / ORIENT BELL, Model: Cool White or similar model in other ceramic tiles makes specified in tender) (Note: Waterproofing compound shall be measured & paid separately)”
Dismantling of brick tiles or terracing tiles, single layer on roofs incl screed bed and removal of debris & rubbish from site including cleaning of surface complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of concrete Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing the rubish off the premise complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
Dismantling of AC corrugated/semi corrugated sheets including ridge as in roof covering and removing off the site complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quaries, arches pillars etc and removing debris off the site complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4 sqm each and removing from the site complete all as specified and directed.
Dismantling of ceiling board incl snap grid frame of any thickness including cover fillets complete all as specified and directed.
Supplying and laying 40mm thick brick tiles, bedded in cement mortar (1:6), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on terrace etc complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for Mild steel works conforming to Fe-290 Gde E-165, framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified and directed.
M&L for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight exc 4 Kg per sqm complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
-ditto- but with 6 to 8 mm dia TMT bars
M&L for Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves etc for rough finished surfaces complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) using 20 mm graded aggregates in slabs supported on walls, beams and columns in floors, roof landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed.
M&L for reinforced cement concrete M-25(design mix) using 20 mm graded aggregates in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified and directed.
M&L for providing precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded aggregates set in cement mortar 1:4 as in landings, cover slabs (for manhole etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces incl formwork complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for brickwork with fly-ash old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M& L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing etc complete all as specified and directed.
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finishes complete all as specified and directed.
M&L 18-20mm thick granite slab in window cills, cooking platform etc and like set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over screed bed 20mm thick in cement mortar 1:4 all as specified and as directed.
Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed.
M&L for providing 25 mm thick, Plain Cement Concrete (1:2:4) type B0 (using 12.5 mm graded aggregates) as in sub base of floor completed all as specified and directed.
M&L for laying and fixing Machine cut kota stone slab flooring 18-20 mm thick over and including 20 mm thick screed base in cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillars etc, fixed over and including 10 mm thick screed bed in cement mortar 1:3, fixed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Vitrified ceramic tiles, light shade, double charged, minimum 8 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and incl screed bed 20mm thick cement mortar 1:4 complete all as a specified and as directed
-ditto- but light coloured double charged vitrified tiles in skirting, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
S&F digital glazed coloured ceramic tiles in vertical surface, as per approved design, size 300 X 450 X 7 mm thick/350 X 250 X 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and incl 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.
Deduct / Add for below / over 5mm or part thereof thickness for item No 53 above (Any storey/ height of building/ structure)
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Reinforcement bars shall be paid seperately)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litre and adhjesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for dubbing out cement plaster (1:4), average 20 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortor (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick to fair faces of concrete surface on ceilings in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per 50 kg bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only"
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted wooden surface and providing one coat of synthetic enamelled paint of any description, over 10cm in width or girth, not otherwise described for complete all as specified and directed.
M&L preparation of old painted steel surface and providing one coat of synthetic enamelled paint of any description, over 10cm in width or girth, not otherwise described for complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 2 mm thick wall putty duly finished to a smooth surface and applying two coats of acrylic bound distemper with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying 2 mm thick wall putty duly finished to a smooth surface and applying two coats of acrylic distemper with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 1 mm thick wall putty duly finished to a smooth surface and applying two coats of acrylic distemper with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying 1 mm thick wall putty duly finished to a smooth surface and applying two coats of acrylic distemper with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and applying one coat of acrylic distemper with rollers complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceilings and applying one coat of acrylic distemper with rollers complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceilings and applying one coat of white wash complete all as specified and directed.
Removing old paint on wooden surfaces of any description over 10 cm width or girth by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Removing old varnish/french polish on wooden surfaces of any description over 10 cm width or girth by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, and applying French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler with two or more coats complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying 2 mm thick exterior wall putty for smooth surface and finishing by applying two coats of weather proof exterior emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for complete removal of existing treatment on walls and applying 2 mm thick exterior wall putty for smooth surface and finishing by applying two coats of weather proof exterior emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for 2nd class hardwood, plain soild, straight chowkhats and frames, wrought, framed rebated on the soild, rounded or chamfered, put together, with glue, pinned at joints complete all as specified and directed.
S&F 5mm thick toughened glass as in hinge doors, partitions, windows, automatic doors and similar works including cutting to shape, drilling holes as required complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made uPVC- Sliding windows/doors having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer shall have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of iron mongery in Ist quality (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles shall have a warranty of 20 years. The profiles shall conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and cost of scaffolding if required for fixing shall deemed to be included in the quoted rate complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)
S&F 35mm thick Factory made 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to receive glass, gauge etc.(with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: Stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F butt hinges, medium weight, stainless steel, 100mm complete all specified and directed
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all specified.
S&F 150mm extruded aluminium handles, fabricated type, anodised complete all specified.
S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all specified.
S&F in repair 15mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
-ditto all as per item No 91 here-in-before but 20 mm bore
-ditto all as per item No 91 here-in-before but 25 mm bore
-ditto all as per item No 91 here-in-before but 40 mm bore
S&F in repair gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
-ditto- but 25 mm bore gate valve
-ditto- but 40 mm bore gate valve
Disconnecting exiting water storage Tank of capacity exceeding 500 litres but not exceeding 1000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water Tank and writting MES No, Unit Name (With capital letter, not exceeding 15cm height and not exceeding 10ms each tank) and re-connecting and refixing all connections complete all as specified and directed.
-ditto- but for water storage Tank of capacity exceeding 1000 litres but not exceeding 2000 liters
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple, ling screw & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
S&F in repair 25 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-153 or equivalent model in JEXON / POLYTUF / SHAKTI)
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:4 complete all as specified and directed.
Making good under cills or over arches, lintels and bressummers in cement mortar 1:4 including all pinning when necessary all as specified and directed.
S&F in repair Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
All as per Item No. 105 above, but for 150 mm bore pipes
S&F CI bends for 100mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
All as per Item No. 107 above, but CI bend for 150 mm bore pipes
S&F 100 mm bore cast iron (sand cast) bends with access door (any radius), diminishing pieces or tapers (larger bore to be measured) complete all as specified and as directed.
All as per Item No. 109 above, but CI bend with access door for 150 mm bore pipes
S&F CI branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches, for 100mm dia pipe complete all as specified and directed.
All as per Item No. 111 above, but CI branch piece for 150 mm bore pipes
S&F Stack clamps for 100 mm dia bore pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
All as per Item No. 113 above, but Stack clamps for 150 mm dia bore pipe
M&L for snap grid system with powder coated aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and powder coated aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with supporting hangar 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
Re-fixing of aluminium snap grid sytem using serviceable grid sections obtained from taking down of false ceiling, fixed to ceiling with supporting 6 mm dia. G.I hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
S&F 'E' board "Classic", reinforced, designer series, ceiling board with HPSC (High pressure Steam Curing) of size 595 mm x 595 mm x 4 mm thick fixed on snap grid system complete all as specified and as directed.
M&L for applying one coat of acrylic distemper wit rollers over a coat of primer on ceiling boards complete all as specified and as directed.
S&F powder coated (medium thickness of powder coating 50 micron) aluminium frame for door, windows, partitions and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed.
Supply and fixing 4.8 mm thick sheet glass frosted on one side, area in squares exc 0.5 sqm in each pane and fixed to aluminium frame work / snap beading complete all as specified and as directed.
S&F Solar control film 25 micron reflective type sticked to glass panes as per manufacturers instructions all as specified and as directed.
S&F Decorative laminate type 1 (0.90 mm thick) of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and as directed.
S&F Door closer hydraulically regulated, designation No. 3, aluminium (die cast) body, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedcomplete all as specified and directed.
S&F 4 lever mild steel type Mortice lock vertical type size 100mm complete all as specified and directed.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 127 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 127 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 127 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 15 Amp AC 230 Volts flush type complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 100 watts, 5 Speed Control, 230/240 Volts complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate body with back plate suitable for batten/pendant fittings or to be mounted on walls complete all as specified and directed.
Re-fixing of of LED light fittings, any type with driver, holder incl LED tube lights, connecting up with three core flexible copper conductor of suitable size from ceiling rose and testing on completion all as specified and directed.
S&F in repair Double Door, Sheet Metal Enclosure for DBs, for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F in repair Double Door, Sheet Metal Enclosure for DBs, for mounting of MCB for 240 Volts, 4 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F in repair MCB, 'C' series, SPN, 40 to 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Taking down of existing exhaust fan, 450 mm sweep from any height, opening the fan, removing the damaged coil and rewinding the coil with suitable gauge of copper wire as per requirement including oiling, greasing and replacement of unserviceable accessories such as capacitor, connector, bearing etc, painting of fan with one coat of synthetic enamel paint by spray painting, re-assembling and fixing in existing location and testing complete all as specified and directed.
M&L for sub main wiring with 2 runs (P-N) of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm 1100 volts grade along with one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm 1100 volts grade as earth continuity conductor drawn through and including adequate size PVC non-metallic concealed conduit incl taking down existing sub main wiring complete all as specified and as directed. (NOTE : Three runs of single core 4.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
M/S SRINIVASA CONSTRUCTION
MODERN AGENCY
DGR CONSTRUCTION
UNITED ENGINEERS
dutta and dutta
JOY-EN-JOY
JAGATMATA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .