Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹78.8 L+₹1.3 L (1.64%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹80.1 L+₹2.6 L (3.31%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L3₹80.1 L+₹2.6 L (3.31%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹73 L
EMD Value
₹1.3 L
Closing Date
10 Dec 2022, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
PROVN OF GUN SHED WITH PLINTH PROTECTION AND PROVN OF MI ROOM IN JORHAT MIL STN
2022_MES_559425_1
84108E8
Open Tender
Civil Works
Lump-sum
240 days
GE JORHAT
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE JORHAT
₹1.3 L
Yes
17 Jan 2023
31 Oct 2022
17 Dec 2022
31 Oct 2022
10 Dec 2022
28 Nov 2022
31 Oct 2022 - 12 Nov 2022
Amount
Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only.
Design and Construction of Gun Shed with Plith Protection in RCC Framed Structure as per Arch Drg No. CWE/DIN/04/22 sht 1/3 and 2/3, and specification given in Sch A Notes and Particular Specifications, including 0.5mm thick Pre-painted Aluminium Zinc alloy metallic Coated sheet roofing on a steel truss, brick wall in CM 1:4 upto roof level, RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE- a) The contractor shall submit along with the tender, structural drawings for based on which contractor shall quote their LUMPSUM RATE. b) Please note that in case of contractor fails to submit structural drgs in Cover-I, the firm shall be rejected in Cover-I and their Cover-II will not be opened.
Design and Construction of MI Room in RCC Framed Structure as per Arch Drg No. CWE/DIN/06/22 Sht No. 1/3 to 3/3, CWE/DIN/EM-4/22 Sht No. 1/1 and specification given in Sch A Notes and Particular Specifications, including RCC roof, brick wall in CM 1:4 upto roof level, RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE- a) The contractor shall submit along with the tender, structural drawings for based on which contractor shall quote their LUMPSUM RATE. b) Please note that in case of contractor fails to submit structural drgs in Cover-I, the firm shall be rejected in Cover-I and their Cover-II will not be opened.
NOTE: Schedule ‘A’ Part II to VIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch ‘A’ Part II (Excavation, Earthwork & Site Clearance)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch ‘A’ Part IV (Internal Water Supply)
Total amount of Sch ‘A’ Part V (External Electrification)
Total amount of Sch ‘A’ Part VI (External Water Supply)
Total amount of Sch ‘A’ Part VII (Sewage Disposal)
Total amount of Sch ‘A’ Part VIII (Road Path and Culvert)
Total amount of Sch ‘A’ Part IX (Area Drainage)
SCH 'A PART X (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
S & F LED tube light nominal power 22 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours with 3 core flexible copper conductor cable of suitable size from ceiling rose. Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED ceiling hanging type tube light nominal power 2 x 22 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours with 3 core flexible copper conductor cable of suitable size from ceiling rose. Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED ceiling hanging type tube light nominal power 2 x 22 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours with 3 core flexible copper conductor cable of suitable size from ceiling rose. Make mentioned under Appendix "B" complete all as specified and as directed.
S and F double stiff pendants comprising of galvanised steel or chromium plated brass bell mouth connectors 2 Nos with back plate and length upto 2x 2 meter long parallel 15mm dia galvaanised or stove enamelled screwed steel conduit with two check nuts for flexible tube light fittings and upto 1.5 m long twin core 0.5 sqmm copper conductor flexible cable complete all as specified and directed
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L for making hole by suitable means for insertion of GI pipe 40 mm to 80 mm for passing cable across the road without cutting the road complete all as directed.
S & F LED street lights nominal power 30 Watt, wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 85 lumens per watt, lumen output of minimum 2500, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CRI greater than 70%, CW available CCT of 6500K, beam angle equals to 120⁰, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LHETBXU7PAIS030 of Havells or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
M & L for construction of new valve chamber of size 600 mm X 600 mm X 600 mm with burnt brick (Sub class B) including necessary earth work in any type of soil, PPC foundation (1:4:8) type D-2 20 mm grade stone aggregate as in base concrete, brick work in CM 1:4 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge.
S & F LED street lights nominal power 60 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours as per catalogue No. ENDURAPEARLPLUSSL60WLED757SASYTOPC of Havells or equivalent of Make including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Supply and fix Thermoplastic cable junction box for street lights of size 155 x 210 x92 mm made of high quality polycarbonate IP-66 (Weather Proof), incl 4 way bakelite cable terminals indl 03 Nos polymide gland, shock proof, rust free, corrosion free, chemical resistant, fire retardant having high impact (IK 08) totally insulated, UV resistant having high grade gasket made of polyurethane with including MCB DP 6 Amps and 2 Nos M32 size cable gland suitable up to 25 Sqmm cable etc, acomplete all as specified and directed
S & F LED tube light nominal power 20 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours with 3 core flexible copper conductor cable of suitable size from ceiling rose. Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED tube light nominal power 10 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours with 3 core flexible copper conductor cable of suitable size from ceiling rose. Make mentioned under Appendix "B" complete all as specified and as directed.
Supply and Fix, LED roadway luminaire, 25 Watts, with pressure die-cast aluminium housing, IP-66, high power LEDs as light source and electronic driver and 10 KV SPD and fixed on pole with 40 mm dia light grade GI pipe (bend to shape) bracket complete with MS flat iron clamp, nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof, ABS plastic body material, stainless steel inner tank material, high - performance porcelain enamel glass lined tank comprising fittings (a) heating unit (b) thermostat (c) indicating lamp (d) thermal cutout (e) drain plug (f) flexible cable of suitable length with 3-pin plug of 16A capacity. (g) provision for vent pipe pressure relief valve/device. (h) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.
Chief Builders &Consultants
M/S A K BROTHERS
M/S SINGH TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .