| Sl No | Description | Qty | Unit | Shree Gajanan Enterprises L2 | MAHESH ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for preparation of old wall surfaces plastered or unplastered and apply one coat of white wash on walls all as specified. | 100 | Sqm | 10 ₹1,000 Lowest | 12 ₹1,200 |
| 2.00 | All as per item No.1 but on ceiling | 80 | Sqm | 11 ₹880 Lowest | 14 ₹1,120 |
| 3.00 | M&L for Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat of distemper oil-emulsion on walls all as specified. | 4,200 | Sqm | 35 ₹1,47,000 Lowest | 40 ₹1,68,000 |
| 4.00 | M&L for washing,rubbing down and stopping of distempered and painted surfaces of ceiling and applying one coat of distemper oil-emulsion on ceiling all as specified. | 1,100 | Sqm | 45 ₹49,500 | 40 ₹44,000 Lowest |
| 5.00 | M&L for Complete removal of existing treatment of distempered and painted surfaces of wall and applying two coat of distemper oil-emulsion over a coat of alkali resist primer on walls all as specified. | 900 | Sqm | 85 ₹76,500 | 60 ₹54,000 Lowest |
| 6.00 | M&L for 3mm thick one coat of wall care putty on wall | 800 | Sqm | 42 ₹33,600 | 40 ₹32,000 Lowest |
| 7.00 | M&L for 3mm thick one coat of wall care putty on ceiling | 450 | Sqm | 60 ₹27,000 | 50 ₹22,500 Lowest |
| 8.00 | M&L for preparation of old surface of wall in any position washing down with water and cleaning the surface from all loose dirt, chalk, grease, fungal etc and finishing wall with one coat of weather proof acrylic paint etc ,complete all as specified and as directed by Engr-in-Charge. | 2,500 | Sqm | 70 ₹1,75,000 | 60 ₹1,50,000 Lowest |
| 9.00 | M&L preparation of old painted steel surface & applying a coat of synthetic enamel paint all as specified. | 140 | Sqm | 68 ₹9,520 Lowest | 70 ₹9,800 |
| 10.00 | M&L for preparation of old wooden surfaces of any description over 10cm width & girth not otherwise described and applying a coat of synthetic enamel paint complele all as specified | 600 | Sqm | 50 ₹30,000 Lowest | 70 ₹42,000 |
Tender Value
₹29.4 L
EMD Value
₹58,800
Closing Date
18 Aug 2025, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
WELCOME MAINTENANCE, PERIODICAL SERVICES TO CERTAIN BUILDINGS, CLEANING TO SEWAGE LINE ,SEPTIC TANK , MANHOLES AND REPAIR TO SANITARY FITTINGS, TILING SUNKEN PORTION INCL PLUMBING AND OTHER MISC WORK AT AF STN YEOUR UNDER GE(AF)THANE
2025_MES_721888_1
8479/E8
Open Tender
Civil Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹58,800
Yes
6 Oct 2025
22 Jul 2025
25 Aug 2025
22 Jul 2025
18 Aug 2025
6 Aug 2025
Amount
M&L for preparation of old wall surfaces plastered or unplastered and apply one coat of white wash on walls all as specified.
All as per item No.1 but on ceiling
M&L for Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat of distemper oil-emulsion on walls all as specified.
M&L for washing,rubbing down and stopping of distempered and painted surfaces of ceiling and applying one coat of distemper oil-emulsion on ceiling all as specified.
M&L for Complete removal of existing treatment of distempered and painted surfaces of wall and applying two coat of distemper oil-emulsion over a coat of alkali resist primer on walls all as specified.
M&L for 3mm thick one coat of wall care putty on wall
M&L for 3mm thick one coat of wall care putty on ceiling
M&L for preparation of old surface of wall in any position washing down with water and cleaning the surface from all loose dirt, chalk, grease, fungal etc and finishing wall with one coat of weather proof acrylic paint etc ,complete all as specified and as directed by Engr-in-Charge.
M&L preparation of old painted steel surface & applying a coat of synthetic enamel paint all as specified.
M&L for preparation of old wooden surfaces of any description over 10cm width & girth not otherwise described and applying a coat of synthetic enamel paint complele all as specified
Taking down cement plaster any description etc incl racking out joints, hacking for key scrubbing down with water etc complete all as specified.
M&L for rendering 5mm thick in CM 1:4 on fair faces of concrete as in ceiling of slab finished even and smooth without using extra cement all as specified.
M&L for rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all as specified.
M & L for rendering 20 mm thick in cement mortar (15 mm thick 1:6 as backing coat and 5mm thick1:4 finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately)
Supply only integral water proofing compound.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for preparing new plastered wall surfaces and applying two coat of OBD over a coat of alkali resistant priming paint complete all as specified.
M&L for preparing new plastered surfaces of ceiling and applying two coats of OBD over a coat of alkali resistant priming paint complete all as specified and directed.
Repairs to Shutters after taking down of any description exc 1 Sqm and n.exc 2 Sq.m each Refixing in same opening complete all as specified and directed.
Taking up down steel tubing and connection 15 mm dia including cleaning for re-fixing or removal to store complete all as specified
S&F steel water tubing 15mm bore of tubing in mm medium grade galvanised with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified
M&L Taking up or down 25mm dia steel tubing and connections incl cleaning for refaxing or removal to store.
S&F GI tubing medium grade 25mm dia with all fittings and fixed complete to walls, ceilings or floors etc complete all as specified and directed.
S&F in repairs PVC connection 15mm bore 600mm long with brass connections & washers complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair low level flushing cistern plastic valve less syphonic action type white with inlet ball valve float chain and ball bracket & capacity 10 ltr ISI marked including 32mm PVC flush pipe complete all as specified and directed.
S&F in repairs Pillar taps, 15mm cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs stop cock valves 15mm cast copper alloy screwed down high pressure with crutch or butter fly handle fancy type, chromium plated screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs bib tap 15mm bore chromium plated cast copper alloy with crutch or butter fly handle but fancy type screwed down screwed for iron pipe complete all as specified and directed.
S&F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repair 20mm Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms complete complete all as specified and directed by Engr in Charge.
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
M&L for Preparing new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters form frame) n. exc 1.5 sqm each.
S&F solid PVC solid door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling and fixing in opening with stainless steel screws of required size complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved.
Taking down chowkhats or frames exc 1.50 Sqm but n .exc 4 Sqm each, removing to or from store, including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts,or otherwise as directed complete all as specified and directed
Refixing wooden shutters of any description in same opening exc 1.00 Sqm but n.exc 2.00 Sqm each, complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters form frame) exc 1.5 sqm & n.exc 4 sqm each
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each or otherwise as directed complete all as specified.
S&F IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified.
S&F for 30 mm thick IInd class HW rail and style plain framed panelled shutter (Two panel) with lock rail and panel of 9mm BWP,commercial ply or 12mm veneered particle beard with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part-I) kiln and chemically pressure treated.
S&F for 30 mm thick IInd class hard wood glazed and Skelton shutters divided into squares with plain chamfered or rebounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rebounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chawkats.
S&F 40mm thick Flush shutters,solid core construction,with block board core and one face plywood face commercial type panels, other face is covered with decorative face veneer with lipping/frame to match etc complete all as specified and as directed .
M&L for 25 x 3mm FI holdfasts for fixing door frame all as directed.
M&L for preparation of new wood surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of pink primer etc complete all as spcd.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 250mm length and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified.
S&F aluminium anodized barrel tower bolt extruded section and fixed 150 mm long all as directed
S&F Floor door stopper 140mm length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.
S&F extruded aluminium alloy handles, fabricated type anodized 150mm long fixed all as directed
S&F butt hinges100 mm long, medium weight, cold rolled mild steel, and fixed all as directed.
S&F mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.5 sqm
S&F sheet glass ordinary quality 3.00mm thick and glazing with oil putty or aluminium/rubber beading in squares n.exc 0.5 sqm in each pane
S&F figured glass, pin-headed type 3.00 mm thick and glazing with oil putty or aluminium/rubber beading in squares n.exc 0.5 sqm in each pane.
Repairs to shutters of any description easing & adjusting without taking down area exc 1 sqm but n. exc 2 sqm
S&F in repair, Drapery curtain rod/ Harrison rails of anodised aluminium alloy complete with MS brackets golden colour rings and sode caps fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and as directed by Engineer-in-charge
M & L For cleaning of OH PVC Service Tank internally by bailing out of water/sludge from bottom of sump, removing all scale, dirt, alges and other growths from entire surfaces of tank and from mouths of circulating pipes by rubbing with wire brushes and by high pressure cleaning method with rotary sets with approved detergents and sucking all dirty water by vacuum cleaners, disinfecting the tank with approved chemical/bleaching powder for making the surfaces bacteria free and cleaning with fresh water, all as directed by EIC. (a) Overhead Pvc water tank upto 500 Litres of capacity Note- cleaning of OH PVC service tanks are safely to be handled Damage and bracing of tanks are on Contractors OWN risk.
All as above item No 61 but exc 500 ltr and n.exc 1000 ltrs capacity.
All as above item No 61 but exc 1000 ltr and n.exc 2000 ltrs capacity.
Dismantling water tank capacity exc 250 and n exc 500 ltr and removing to store all as directed
Dismantling water tank capacity exc 500 and n exc 1000 ltr and removing to store all as directed
S&F 500 Ltr Rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by Engr in Charge.
S&F1000 Ltr Rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by Engr in Charge.
S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr in Charge.
Taking down steel tubing & connections incl cleaning for refixing or removal to store for 20mm bore of pipe all as specified and directed by Engr in Charge.
M&L for 20mm bore medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors all as specified and directed by Engr in Charge.
Refixing old GI steel tubing with and including necessary fitting& connections in new or old position (walls, ceiling, floors etc) 15 mm bore of pipe all as specified and directed by EIC.
Refixing old GI steel tubing with and including necessary fitting& connections in new or old position (walls, ceiling, floors etc) 20 mm bore of pipe all as specified and directed by EIC.
M&L in repairs Orissa pattern vitreous china ware water closet white glazed of pan size 580x440mm with integral foot rest fixed flushed pipe including all joints and making good to the floor all as specified and directed by Engr in Charge.
S&F in repairs wash down water closet (EWC) (pedestal pattern) complete(excluding flushing cistern or flush pipe) all as specified and directed by Engr in Charge.
S&F in repair vitreous china wash hand basin white flat back size 550 X 400 mm excluding taps waste chain and plug and porcelain stopper but including brackets complete all as specified and directed. .
S & F in repairs brass CP mixer for mixing hot & cold water screwed down for iron pipe15mm dia all as specified and directed by Engr in Charge.
S&F in repairs quarter turn stop valves CP Brass fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm dia all as specified and directed by Engr in Charge.
S&F 15mm dia pillar tap chromium plated cast copper alloy with capstan head, fancy type screwed down high pressure with or with out letters Hot or cold with long screwed for iron pipe all as specified.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed
Supply and fix 40mm GI pipe, medium grade in isolated length of 400mm long inserting into wall surfaces with 100mm projecting from the external face of wall as in water draining spout complete all as specified and directed.
Material and labour for rendering in CM (1:3),10mm thick on wall of sunken floor surfaces finish the surface even and smooth without using extra cement mixed with water proofing compound complete all as specified and as directed (Note : WPC will be measured and paid in supply only rate)
Materials & labour for water proofing treatment to sunken floors with the following courses of treatment :- (a) Apply first layer of slurry of cement @ 0.488 kg/sqm mixed with acrylic polymer modified cementitious composite compounds @ 0.126 kg/sqm all as specified. (b) Apply second layer of slurry of cement @ 0.242 kg/sqm mixed with acrylic polymer modified cementitious composite compounds @ 0.253 kg/sqm including cleaning the surfaces and all as specified. (c) Apply 200 micron thick polythene film pasted with the help of adhesives shall be provided over treatment all as specified. Note :- The slope of slab shall be 1:20 towards the corner of outer walls and GI pipe of 50mm dia (medium grade) be inserted at corner projecting out side 10 cm which should be measured and paid separately,
Material and labour for cement concrete 1:5:10 type E2 (using 40mm stone aggregate) as in filling in sunken floor complete all as specified & directed.
Supply and fix salt glazed stoneware traps "P" type with 100 mm bore of pipe fixed in repairs setting the trap and pan in 150mm thick all around cement concrete including taking down old trap complete all as specified and as directed
Supply and fix PVC (SWR) multi floor trap 75 mm with grating including jointing with solvent cement complete all as specified and as directed
supply and fix as in repair cast iron Nahani trap of 100mm dia including jointing to waste pipe fixed in cement concrete type 1:2:4 type B1 complete all as specified and as directed .
Dismantling cast iron drain pipes of any description complete all as specified and as directed.
Supply and fix 100mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall with MS clamp complete all as specified and as directed.
All as per item No 88 above but 75 mm bore.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F (SWR) pipe 110mm bore, type A, single socketed, in any length with rubber ring joints fixed to walls with and including PVC clip complete all as specified and as directed.
All as per item No. 91 above but 75mm.
Supply and fix PVC bend/shoe 110mm dia all as specified and as directed.
All as per item No. 93 above but 75mm dia pipe.
Supply and fix 110 mm PVC (SWR) branch pipes single Y equal or unequal with complete accessory complete all as specified and as directed.
All as per item No. 95 above but 75mm dia pipe.
S&F 110mm dia (SWR) vent cowl complete all as specified and as directed.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and as directed.
S & F PVC (SWR) 75 mm branch piece, double (double Y) equal or unequal complete all as specified and as directed.
S&F PVC (SWR) 110 mm branch piece, double (double Y) equal or unequal complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stone and rubbish of the premises.
Material and labour for non-skid coloured ceramic tiles 7 to 8 mm thick (square or rectangle) area of each tile exceeding 0.06 Sqm but not exce 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for Glazed ceramic tiles in vertical surface 350x 250x7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
S&F PVC waste pipe, 32mm bore suitable to waste coupling pipe attach with rubber ring joints fixed to waste coupling of sinks/WHBs complete all as specified and directed.
S&F in repair PVC cover for tanks of capacity 500 to 1000 ltrs including taking out old broken covers with GI nuts and bolts 3/16" dia and 1" long bolts with washers (8 Nos with each cover and 2 Nos hinge bolts and nuts 8 mm dia 50 mm long complete all as specified and directed.
S&F in repair 32mm dia Waste coupling of PTMT (half or full threaded). (Minimum weight 32mm?45gms/40mm-60 gms)
S&F in repair 40 mm dia Waste coupling of PTMT (half or full threaded). (Minimum weight 32mm?45gms/40mm-60 gms
Systematically cleaning of 150 mm dia to 450 mm dia pipe of sewage/drains by passing rope knots, bamboo, kampti and disc of required size from manholes to manholes, septic tank and well flushing after cleaning sewer line/drain pipe with water (excluding septic tanks) Cleaning/clear of blockage of manholes, gully traps, floor traps, vertical soil/waste pipe of different dia and sewage line in the area of AFS K hills by providing and deployment of 02 (TWO) Nos of Labours per day including Sundays and Holidays. Note : (a) The labour (02 nos) will report daily at 0845 hrs on all working days including Sundays and holidays at complaint cell centre to attend complaints given by EIC.Complaints needs to be cleared within 24 hrs after receiving the complaints. The contractor will deploy requisite labour and supply all T&P ( mechanical Iron rods, knot ropes , bamboo etc.) scaffolding ladders any other materials required to clear the blockages at the site without any extra cost .Labour for cleaning of sludge from sewage lines (any dia) to manhole is included in quoted rates. In case any labour does not report to EIC for the whole day or found missing more than half an hour on any day, Panel recovery @ RS.900/- per head per day shall be made proportionally from contractor's dues. (b) The recovery will be made from the contractor @250 Rs per complaint which are not cleared within 24 hrs from the date and time of receipt of complaints. Decision of EIC is final in this respect. Two persons will be provided by the contractor at site. The above item includes conveyance cost of labour with their tools to travel from pocket to pocket to attend complaints including removal of sludge from the site outside MOD land to a distance not exc 5km (The department shall not be liable to provide any kind/form of transportation to the labour). (c) Registers of labour attendance and complaints slips shall be maintained by contractor at their own cost, which shall be kept in the custody of MES Department(complaint cell) duly signed by contractor's representative ,JE(civil) and Engineer in charge. (d) The documents viz. attendance register, complaint register, log sheet / record of complaint made / attended shall be maintained separately for each locations / complaint centre. (e) The police verification with regard to antecedent and character of tradesmen engaged by the tenderer, shall be carried out by the contractor at his own expenses before obtaining temporary pass on monthly basis. (f) The police verification report, showing names and addresses of tradesmen shall be required to be submitted to the Engr-in-Charge/GE as and when asked for. (g) The contractor shall submit attested copies of necessary safety insurance for subject tradesmen/supervisor employed for the execution of contract.
Opening cover of septic tank, dewatering and taking out night sludge etc from septic tank and removing sludge outside MD land and cleaning the septic tank as per BMC rules and placing the cover in original position ,complete all as specified and as directed by Engr-in-charge. Note: (i) All T&P including labour shall be provided by the contractor at their own cost. (ii) The measurement for the quantity of sludge removed will be arrived by multiplying the inner dimensions of septic tank to actual depth of sludge deposited by dipping the measuring rod. The depth shall be of that wet surface on measuring rod for payment purpose.
Demolition of brickwork or stone boulders masonry built in CM for foundation etc or for shafts, walls cesspits, manholes etc complete all as specified and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete block (1:3:6), type C1 (using 20mm graded stone aggregate) straight or curved on plan exc 6 mtr mean radius, exc 10 cm width and set in CM (1:6) all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement complete all as Specified.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge.
Cement concrete with type C2 1:3:6 (40 mm graded aggregate) in surface channel and drains and sides of Bldg as plinth near manhole of bldg complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc (Inner girth only measured) complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up 150mm bore drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar and removing and depositing the debris to a distance n.exc 50mm complete all as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and n exe 1.5 mtr in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, sewage lines, etc. not exceeding 10 Sqm on plan and getting out in soft /loo soil. complete all as specified and directed by Engr-in-Charge.
M&L for Salt glazed stone ware drain pipes grade 'A' internal dia of pipe 150 mm laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed by Engr-in-Charge.
M&L cement Concrete bed to drain pipes including packing under and completely surrounding pipes after they are laid and tested in cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) bore of pipe is 150 mm complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs salt glazed stone ware gulley traps, square or round mouthed type 'P' of size 180 mm x 150 mm complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping benching for manholes etc including weathering slighting rounded or chamfered angles and throating including necessary formwork complete all as specified and directed by Engr-in-Charge.
Demolition of RCC Manhole covers, slabs etc of any description and in any position not specifically provided for.
M&L for precast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in manhole cover of any section with plain fair faces including chamfers, weatherings, throating etc and setting in cement mortar 1:4 complete with joints to match.complete all as specified and directed by Engr-in-Charge.
M & L for TMT bars 10 mm dia and over, cut to length bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connect in new drains making good to pipe and rendering cutting out existing benching for and forming branch channel ½ round or ¾ section in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, levelling watering and well ramming in layers n.exc 25cm each layer in soil complete all as specified and directed by Engr-in-Charge.
Removing surplus soil n.exc 50 mtr away deposited where directed n.exc 1.50 mtr high from the starting point complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction, single 'T' (equal or unequal) 110 mm dia ,complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction, single 'T' (equal or unequal) 75 mm dia ,complete all as specified and directed by Engr-in-Charge.
Shree Gajanan Enterprises (BID ID -3397457)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .