| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹4.9 L+₹16,155 (3.42%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹4.9 L+₹16,722.50 (3.54%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹5.5 L+₹81,400 (17.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹5.8 L+₹1.1 L (22.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹7.2 L
EMD Value
₹14,400
Closing Date
9 Jan 2021, 6:00 pmClosed
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS PER BOQ AND TENDER DOCUMENT
2020_MES_404855_1
GE(S)/B/8480/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹14,400
Yes
3 Apr 2021
18 Dec 2020
11 Jan 2021
18 Dec 2020
9 Jan 2021
4 Jan 2021
18 Dec 2020 - 24 Dec 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring in conduit with PVC insulated, unsheathed, single core multistranded copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through PVC conduit and fixed in sunk boxes and covered with new 3.0mm thick ISI marked laminated sheet cover and brass screw with cup washers for switches/sockets/regulators etc. for one light /CB/fan point controlled by one type switch all as specified and as directed.
All as per item No. 2 here-in-before but for one 3 pin 5 Amps socket point on the independent board with other switches all as specified and as directed.
All as per item No. 2 here-in-before but for one 3 pin 5 Amps socket point on the same board with other switches all as specified and as directed.
All as per item No 02 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket all as specified and as directed..
M&L for point wiring surface type with single core 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable (FRLS)including 1.5 Sqmm PVC insulated unsheathed copper conductor as earth continuity conductor drawn in and including ISI marked PVC casing caping not less than 20mm width with its accessories, and fixed in existing sunk boxes and covered with new 3.00 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc.one light/CB/fan point controlled by one switch complete all as specified and as directed.
All as per item No. 6 here-in-before but for one 3/2 pin 5 Amps socket outlet point on independent board all as specified and as directed.
All as per item No. 6 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15 amp socket all as specified and as directed..
S &F switch piano flush type, 5 Amps single pole, one way, 230 volts all as specified and as directed.
S &F switch socket combination 2 in 1, 3 pin 5 Amps flush type universal all as specified and as directed.
S &F switch socket combination, 2in1, 3pin, 5 Amps and 15 Amps, flush type all as specified and as directed.
S &F switch socket combination 2 in 1, 3 pin 5 Amps all as specified and as directed.
M&L ceiling rose surface bakelite 65x50 mm two to three terminals all as specified and as directed.
S&F stepped type electronic fan regulator flush type ,230V AC all as specified and as directed.
S&F stepped type electronic fan regulator modular type, 230V AC all as specified and as directed.
S&F call bell 5 Amps single pole, one way,230 volts all as specified and as directed.
S &F MCB SP 06-32 Amp, AC, 240 volts, 50 Hz, 10 KA rating "C' Curve including taking down old MCBs complete all as specified and as directed. Make: Indoasian Cat No: 811122 to 811129/Legrand Cat No 408587 to 408595/ Schneider Cat No A9N1P06C to A9N1P32C
S &F MCB SPN 6 -32 Amps, 240 Volts 50 Hz, 10 KA rating "C' Curve including taking down old MCBs complete all as specified and as directed. Make: Indoasian Cat No: 811144 to 811151/ Legrand Cat No 408609 to 408617/ Schneider Cat No A9N2P06C to A9N2P32C
S &F MCB TPN 63 Amps, 415 Volts 50 Hz, 10 KA rating "C' Curve including taking down old MCBs complete all as specified and as directed. Make: Indoasian Cat No: 811220 or quivalent make of ABB/L&T
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, SPN 8 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including taking down old unserviceable one complete all as specified and as directed. Make: Indoasian Cat No: 811807 or equivalent in Havells/Legrand/Standard.
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, TPN 12 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including taking down old unserviceable one complete all as specified and as directed. Make: Indoasian Cat No: 811845 or equivalent in Havells/Legrand/Standard.
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows including taking down old unserviceable one complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
Supply and fix LED batten type, 5 watt, 1 feet long, suitable for indoor applications with integrated electronic driver of operating voltage 110 to 265 Volts Lumin output not less than 900 lm including connecting up and taking down existing unserviceable surface/ ceiling mounted 14/18/20 watt FTL fitting complete all as specified and as diretcted. Make:- Bajaj Cat No : BCLSB 05 NW/C&S Cat No LTTB1F5WLEDEW/BATTEN or equivalent in Crompton Greaves
Supply and fix in replacement LED Bulk head 10 Watt with PDC aluminium housing and milky diffuser complete all as specified and as directed. Make Bajaj Cat No : BIBWP10WLED/C&S Cat No LTB10WLED/CG Cat Part No. LBH-10-CDL
Supply and fix LED batten type, 10 watt, 2 feet long, suitable for indoor applications with integrated electronic driver of operating voltage 110 to 265 Volts Lumin output not less than 900 lm including connecting up and taking down existing unserviceable surface/ ceiling mounted 14/18/20 watt FTL fitting complete all as specified and as diretcted. Make:- Bajaj Cat No : BCLSB 10 WH/C&S Cat No LTTB2F10WLED/W/ Crompton Cat No LCTL-9-CDL
Supply and fix LED batten 20 watt, 4 feet long suitable for indoor applications with integrated electronic driver of operating voltage 110 to 270 Volts , Lumin output not less than 1800 lm including connecting up and taking down existing unserviceable surface/ ceiling mounted 28/36 watt FTL fitting complete all as specified and as diretcted. Make:- Bajaj Cat No. BCLSBAL 20W CW/C&S Cat No. LTTB4F20WLED/W or equivalent in Crompton
Supply and fix LED batten 18 watt, 4 feet long suitable for indoor applications with integrated electronic driver of operating voltage 110 to 270 Volts , Lumin output not less than 1800 lm including connecting up and taking down existing unserviceable surface/ ceiling mounted 28/36 watt FTL fitting complete all as specified and as diretcted Make:- Bajaj Cat No. BCLSBAL18W CW/Crompton Cat No LCTL-18-CDL or equivalent in C&S.
M & L earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion and taking down old one all as specified and as directed .
Supply and fix of ceiling fan complete with electronic type regulator and accessories 230 V, 1200mm sweep, BEE 5 star rated, ISI standards, RPM 340, Air Delivery 210CMM, down rod length 300mm, rust - free powder coated finish and pre-wired and including connecting up with twin core twisted flexible copper conductor cable with connector including dismatling old one deposit to AGE E/M Store yard complete. Make:- Bajaj Electra 50 Product code 250524 or equivalent in Crompton/Havells.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm x 4 core including taking down unserviceable UG cable complete all as specified and directed. Note:- Excavation,sand cushioning, bricks laying shall be measured and paid seperately under relevant item of this schedule.
All as per Item No.30 here in before but of size 50 Sqmm x 3.5 Core etc complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m area and getting out in hard/dense soil etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil etc complete.all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as specified and as directed.
Supply and spread river sand to required width at bottom and top for cable cushioning all as specified and directed.(8cm before laying the cable and 15cm after laying the cable and punned into 18 cm thickness) Note: Punned thickness only shall be measured and paid.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection,locally available best quality,deisgnation 75 all as specified and directed.
S&F galvanized Iron light grade pipe of 50mm dia including fittings etc for cable protection under road/floor/trenches etc complete all as specified and directed.
GS TRADERS
RRK PROJECTS
MAJ CONSTRUCTIONS
SREE VARU ELECTRICALS
NUTHANA ENTERPRISES
Elite Constructions
LITE SYSTEMS INDUS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .