Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.1 L+₹12.7 L (38.2%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹47.8 L+₹14.5 L (43.4%)Rejected-Finance 1331 GENERAL GANJ OPP WATER TANK MATHURA 281001 | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura
As per tender documents
2024_MES_638519_1
CWE/MTR/E of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (East) Mathura
As per NIT documents
7 documents required · 7 mandatory
₹500
GE (E) Mathura
₹1 L
Yes
7 Mar 2024
20 Jan 2024
24 Feb 2024
20 Jan 2024
17 Feb 2024
3 Feb 2024
Amount
M&L for making of surface for painting duly scrubing the existing paint and apply of two coats of existing synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and directed by Enginner-In-Charge.
M& L for welding works to LT Panel/Bus Bar/Feeder pillar box for fixing hinges, locking arrangement or reapir pitted area etc at site complete all as specified and as directed.
Cutting wild grass, bushes, creaper, unwanted vegetation and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance from inside / surrounding of E/M sub station (transformers) including cutting creapers from barbed / cattle fencing of the sub stn as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura complete all as specified and as directed. Note :- (a) The item shall be operated maximum two times in entire period of contract in the same installations. (b) Area measured separately each time.
Supply and fixing in replacement of 3 phase volt meter, 0 --500 volt digital type square or rectangle type 96 sq mm lamp accurracy glass-1 complete all as specified and as directed. Make:- AE/ENERCON/L&T/CONVERZ
supply and fixing in replacement of 3 phase Ammeter, 0 --200 Amp digital type square or rectangle 96 sq mm lamp accurracy glass-1 complete all as specified and as directed. Make:- AE /ENERCON/L&T/CONVERZ
Supply and fixing in replacement of CT coil suitable for Amp meter 100 /5 Amp complete all as specified and as directed. Make - AE /ENERCON /EPCOS/CONVERZ
Supply and fixing in replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one complete all as specified and as directed. Make-L&T /C&S /ABB/CONVERZ
Supply,installing,commissioning and testing of LT Bus Bar outdoor type,cubical type made out CRCA sheet 3.15 mm thick,inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with suitable size of aluminum bus bar 200 Amp-04 Nos (three phase & neutral) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 200 Amp,4P, 16 KA (I/C)- 01 No (b) Aluminium Bus bar (RYB & N) with 4 Nos outgoing arrangement - 01 Set (c) Three Phase LED Indicator switch RY & B-01 Set (d) Digital Amp meter(0-250Amp) and Volt meter (0-500 Volt)-01 Each
Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx50mm thick complete all as specified and as directed.
Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx25mm thick complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil complete all as specified and as directed.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed. Note:- Measurement shall be taken after gentling puning of sand.
Supply and laying PCC cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area :-
16 Sqmm 4 core.
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
150 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 35 Sqmm complete all as specified and directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Supply,installing,commissioning and testing of LT panel board outdoor type,cubical type made out CRCA sheet 3.15 mm thick,inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar 400 Amp-03 nos for phase & 01 No for neutral ,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 200 Amp,4P, 25KA,Ics=100%Icu, adjustable thermal based released (I/C)- 01 No (b) MCCB 63A, 16 KA, 3 Pole,Ics=100%Icu,fixed thermal and fixed magnetic (O/G)- 04 Nos (c) Digital meter with Voltmeter (0-500V) - 01 No (d) Rating of CT & Ammeter as per Bus bar capacity as mentioned in BOQ (e) Indicationg Lamps (R,Y,B) - 01 Set
M&L in replacement for earthing complete with galvanised steel earth plate electrode 60x 60 X6 mm thick, buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level,connected to and including GI strip 32 X 6 mm as earthing lead by means of bolts,nut check nut and washers of galvanised iron all as shown inin electrical plate No 5 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil,PCC (1:3:6) type C1 chamber ,MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric with cast iron frame,funnel with wire mesh,GI watering pipe 20 mm dia medium grade and lugs complete all as specified and as directed. Note:- GI Strip beyond 7.5 meter length from earth electrode shall be measured and paid separately.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
M&L for Copper strip of size 32x6 mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle.Note:- Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc is included in quotated rates complete all as specified and as directed.
M&L for copper earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal (2 Qtl) and common salt (2 Qtl) filling,watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing (all as shown in electrical plate No 5 and commissioning complete all as specified and as directed.
Supply and laying 80mm bore GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and directed.
Supply and laying 100mm bore GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and directed.
Excavation in post hole (or similar hole) each n exc 0.5 cum,getting out,returning,filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
M&L for providing cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete all as specified and as directed.
Supply only chain link fencing made out of mild steel galvanised wire of any size complete all as specified and as directed.
Fixing only chain link fencing including line wires,any mesh,sizes and type to any type of strandards,rail,straining bolts etc including provision of binding wire complete all as specified and directed. Note:- (i) Supply only fencing will be measured and paid separately. (ii) Supply and fix mild steel nut bolt,line wire and flat will be measured and paid separately.
Supply and fix mild steel section fin post and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc or flat iron fillet (for security wire mesh etc) including all necessary drilling bolting or riverting etc complete all as specified and directed.
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long & dia of shank 11 to 15 mm compele all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise desenbed and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed.
Supply and fixing in replacement of MCCB 400Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 315 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 250 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 200 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 160 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 100 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 63 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 250Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 200Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 160Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 125Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 100Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 80 Amp to 100 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 125 Amp to 200 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 200 Amp to 400 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 500 Amp to 630 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
Dismantling of old unserviceble Aluminium conductor off sizes from existing over head lines complete all as specified and as directed.
All as item No. 51 above but GI wire/stay wire.
Dismantling / taking down old unserviceable pin/loop/shackle type insulator any type / size complete all as specified and as directed.
Dismantling of stay assembly complete from site complete all as specified and as directed.
M&L for ACSR conductor any sizes drawn over for over head lines fixed to insulators with binding wire after allowing specified sag complete all as specified and as directed.
M&L for GI wire 4mm dia as continuous earth wire, guarding and craddles to OH line including binding wire complete all as specified and as directed.
Supply & fixing pin type porcelain vitreous insulator 100 mm height and 65 mm dia for 1100 Volts grade including galvanised mild steel spindle, one nut and two washers complete all as specified and as directed.
Supply and fixing shackle type insulator porcelain vitreous white,brown and green of size 75 mm height and 90 mm dia incl galvanised MS straps 32x3 mm size ,washers,insulator bolt 12 mm dia and nut for working pressure 1100 Volts grade complete all as specified and as directed.
M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete all as specified and as directed.
M&L for stay assembly complete with MS stay plate 300x300x6mm thick galvanized stay rod not less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I complete all as specified and as directed. (Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be included in the item rates.
Dismantling U/S any size of cross arms and anti climbing devices from pole /structures. complete all as specified and directed.
M&L for work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
ISHWAR ENTERPRISES
JWALA ELECTRIC CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .