CA NO CWE/SGNR/TOKEN - 38 OF 2022-23 REPAIR AND MAINT TRANSFORMER , VCBS, HT OVER HEAD LINE, HT CABLES AND ITS CONNECTED WORKS UNDER GE FARIDKOT MIL STN
2022_MES_560387_1
CA NO CWE SGNR T-38 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE FARIDKOT
AS PER NIT
10 documents required · 10 mandatory
₹500
GE FARIDKOT
₹60,000
Yes
20 Jan 2023
29 Oct 2022
28 Nov 2022
29 Oct 2022
26 Nov 2022
12 Nov 2022
Amount
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil complete all as specified and directed by Engineer-in-charge.
All as per item No 1 here-in-before but depth exc 1.5 m and not exc 3m for poles
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-charge.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. .
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M&L for laying burnt old size bricks , sub class "B" bricks straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc suitable for inserting GI pipe of upto 80mm dia bore pipe for cable passing without damaging existing road/path/hardstanding/floor by manual using trenchless technology tools/necessary equipment complete all as directed by the Engr-in-Charge.
S & F 80mm dia GI tube light grade with all fitting and fixed to wall and celling or laid in floors/under road etc with mild steel clamp , bolts ,nuts and washers complete all as specdied and directed by Engineer-in- Charge.
All as per item No 8 here-in-before but 100 mm dia pipe.
Supply, laying, jointing, testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work, brick protection, sand cushioning and GI protection pipes shall be measured and paid separately under respective item of BOQ.
Supply, laying, jointing, testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 120 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work, brick protection, sand cushioning and GI protection pipes shall be measured and paid separately under respective item of BOQ.
S & F in replacement Pre-stressed cement concrete pole, 11 metre long of cross section 152mm x 152mm at top and 152 mm x 260 mm at bottom, class 9, complying with requirements of IS-1678-1998 errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30 cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement stay assembly complete with accessories as shown electrical plate No. 1 of SSR Part I for HT poles with 20 mm dia stay rod complete all as specifed and directed by Engineer-in-Charge. Note: Loop type insulator excavation and concrete will be measured and paid seperately under relevant item of BoQ.
S&F in replacement of jumper wire PVC bedded electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 70 sqmm single core as jumper /connecting lead on section pole of OH, GODs, HT Fuses etccomplete all as specified & directed by Engineer-in-charge.
S&F in replacement of jumper wire PVC bedded electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 50 sqmm single core as jumper /connecting lead on section pole of OH, GODs, HT Fuses etccomplete all as specified & directed by Engineer-in-charge.
Re-stretching of existing HT/LT aluminum conductor steel reinforced (ACSR) of any size (In-situ) on over head lines fixed on insulators from 02/04 pole structure after loosening from insulators and fixing on pin, Disc insulator same with new aluminum binding wire 2 mm dia complete all as directed. Note : Pin insulator and disc insulator shall be measured and paid separately under respective item..
Cutting/ trimming of tree branches not exc 10 cm girth touching/approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT/HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified & directed by Engineer-in-charge.
Surface dressing not exceeding 15cm deep in soft/loose soil including cleaning of E&M installation premises, uprooting of tiny trees, tree cutting , cleaning , leveling , spreading bushes, beeds, grass and removing poly bags, brick bats, stone pebels debris , Cleaning of sub station bldg , two pole / four pole structuire area , HT line etc complete all as specified and directed by Engineer in Charge.
Supplying and straining in replacement GI earth wire 4 mm diaas in guarding cradle on HT/LT overhead line, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Heavy duty gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 11 KV 200 Amps complete all as specified and directed by Engineer-in-Charge
S&F in replacement Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut & bolt ,with hardware for 11 KV grade complete all as specified and directed by Engineer-in-Charge
S&F in replacement HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, vitreous145mm high and 255 mm dia and socket type, clamps etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement lightening arrestor HT 11KV pole mounting with insulator complete with all fittings including brackets, clamps, nuts, washers & connection , transmission class nominal discharge current upto 65 KA complete all as specified and directed.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and directed by Engineer-in-charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and directed by Engineer-in-charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm complete all as specified and directed by Engineer-in-charge.
Supply and applying petroleum jelly on GOD/ 66 KV GRID after removing carbon, dust etc complete all as specified and directed by Engr-in charge.
M & L for PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate for repair of earth pit, cable duct PCC near GOD and transformer, etc as directed by Engineer-in-Charge.
M & L for filling and spreading 40mm graded aggregate around 4 pole , 2 pole structure, 66 KV GRID Structure and transformer etc.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of LT/HT any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
Supply, straining and stringing of Aluminium conductor steel reinforced (ACSR) conductor including binding wires of suitable size and suitable conductors / parallel grooves clamp etc other jointing materials for overhead lines of any sizes as required at site including cutting of tree branches falling on the site of work comlete all as specified and as directed.
Dismantling/ taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge. Note :Cost of cutting of bolts (Slag bolts) if reqd shall deemed to be included in the unit rate quoted for this item.
M&L for fabrication of cross arms bracings supports,clamps and back plates,iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and two coats of synthetic enamel paint complete all as specified and as directed by Engr in charge.
Collecting & transporting carefully the unserviceable step down transformers 11000/433 volts 3 phase 4 wire oil cooled copper/ aluminium wound of capacity 63 to 150 KVA (outdoor/indoor type) from AGE (E/M) store yard, stripping up of winding/ core to ascertain the defects/ defective parts, transporting to work shop and replacement of defective parts,, insulting materials impregnated paper, cleaning & desclaing the transformer scraping out of old paint & spray painting with superior quality smoke grey syntheic enamel paint to all exposed surface, assembling the transformers, filling dehydrated new oil complete after repairs, testing and writing MES & SM Numbers with white paint over black base in letters of height not less than 10 cm, transporting back to site from repair workshop and installing, hoisting of transformers on two/four pole sturcture at height not less than 3 meter, making all electric connetions with HT/LT side jumbers and leads including earth connections etc. and testing complete all as specified and directed by Engineer-in-Charge Note : i) Transformers shall be got repaired form factory/ work shop as directed by Engineer-in-Charge ii) The transformer shall be dismantled in presence fo contractor and MES representative/AGE E/M iii) The defective parts to be replaced shall be measured & paid for separately as supply only under respective items of BOQ (iv) Safe oil container for collecting old transformer oil will be arragement by contractor. (v) The T&P such as chain pulley, crane for loading unloading, transporting and for installing and hoisting shall also be arranged by the contractor at his own arrangement.
All as per item No 35 above but of capacity 160 to 500 KVA
All as per item No 35 above Voltage stabiliser 630 KVA to 6.3 MVA
Supply only in replacement of defective HT/LT coil DPC copper windings strip of existing size (gauge), or cross section of winding wire corresponding to aluminium winding as per reccomendation and design of OEM grade and in weight as per existing old coil complete with insulating material for transformers 63 KVA to 500 KVA Capacity , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of HT porcelain bushing including heat resistance gasket, brass spindles, nuts, bolts washers for transformers of capacity 63 KVA to 250 KVA, complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of HT porcelain bushing including heat resistance gasket, brass spindles, nuts, bolts washers for transformers of capacity 400 KVA to 500 KVA, complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement LT brass bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 63 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of LT brass bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 200 KVA to 500 KVA complete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacementof silica gel breather assy including filled sillica gel complete as per size fixed for transformer of capacity 63 to 150 KVA complete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement of silica gel breather assy including filled sillica gel complete as per size fixed for transformer of capacity 160 to 400 KVA complete all as specified and directed by Engineer-in-Charge
Top up with fresh transformer oil in transformer in-site after filtration / dehydration with minium dielectric strength of 55 KV complete all as specified and directed by Engineer-in-Charge Make : Savita / Ascorl / Power oil
Dehydration/filtration of transformers oil of existing transformers (out door/indoor , step up/step down) ,/ Voltage stabilizers at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minimum dielectric strength of 42 KV by continoues process of dehydration complete including testing at standard gap of 2mm by oil testing machine complete all as specified and directed by Engineer-in-Charge Note :- (i) Electricity for running dehydration machine & testing shall be provided by the deptt free of cost. (ii) Testing machine to be arranged by the contractor under his own arrangement.
Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 63 to 500 KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM Number with white paint over black base in letters not less than 10 cms in height complete all as specified and directed by Engineer-in-Charge . Note : Painting & cleaning carried out as per location of transformer site
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 32 x 6 mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth strips connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia and watering pipe 20mm dia GI medium grade with socket and above ground level including earthwork, PCC chamber in PCC (1:2:4) type B-1 using 20mm stone aggregate, cast iron cover, wire mesh etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) Cost of earth lead GI strip connecting upto pump,Gen set,LT panel and DBs earth connection or earthing test point is included in this item (7.50RM). (iii) GI pipe 40 mm dia protection pipe shall be provided upto earthing test point.
Disconecting electric supply and Comprehensive maint of existing HT 11 KV VCBs from housing and cleaning, rubbing and overhauling the mechanical parts and Servicing of 11KV in door VCB, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing ( IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer( Set of three) by PRIMARY INJECTION KIT ,and Testing and calibration of relay( set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specified and directed by Engineer-in-Charge. Note:- (i) The new spare parts required for replacement shall be measured and paid separately as Supply only. (ii) Relevent T&P and testing equipments/tools and minor accessories are arranged by the contractor and included in the unit rate of item.Make of VCB : Areva / CG / Schnieder
Supply & fixing in replacement bushing SPOUT Set vertical type of epoxy resin with brass buss , colour red epoxy including connected of alluminium bus bar as per size - 03 Nos, for 400 A, 11 KV VCB Switch , etc with connetion complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement current transformer CT Ratio 100/50/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge
Supply only in replacement current transformer CT Ratio 200/100/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge
Supply only in replacement current transformer CT Ratio 300/150/5+5A of 11 KV, 15VA, Core 1, class - 0.5 complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Auxillary switches provide remote electrical indication if the circuit breaker is open or closed. they are provided two -switch combinations, with a maximum of two switch combinations for the NF frame and six two switch combinations for the RF frame complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Jaw Cluster contact rating 800 Amp , copper 99.9 % electrolite silver plated for VCB complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement CLOSING coil assembly voltage rating 110 V,DC of existiing specification complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement TRIPING coil assembly voltage rating 110 V,DC of existiing specification complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement multifunction meter conserv EM 6400 complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement Master Trip Relay , BR1231387, 110 Volt DC Supply complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement Ammeter ALPHA A , as per size complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement TNC Switch , three position switch , as per size complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement Segment gear for 11 KV Mechanism Assembly , as per size complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement Z Switch , Z type switch , Micro limit , 11 KV Windsor as per size complete all as specified and directed by Engineer-in-Charge
Supply only in replacement Vacuum Interrupter type WL-34370 C2 suitable for 11 KV VCB Panel complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement indication lamps comparising CB ON, CB OFF, Spring charge, trip cuircuit indicators etc.capacity as per existing old. Note:- Colour code as per existing (R,Y,B,G,W)
Supply and fixing in replacement strip heater suitable for 11KV VCB panel 80 watt all as specified.
S&F in replacement HT self fusing insulation tapes (without compound) of size 38 x 0.76 mm, 10 m long for VCB Bus bar insulation complete all as specified and directed by Engineer-in-Charge
Supply & spray for Anti Track coating compound spray - 320, brick Red colour all as specified and directed by Engineer-in-Charge Make: MOSIL Lubricants or equivalent
Supply and fixing in repalcement of power pack 240 Volts AC/24 Volts DC supply suitable working on tripping system complete all as specified and directed by Engineer-in-Charge. Make : Maha mai Engineers
Supply, install, testing in replacement Comperhensive numerical protection relay : Model Type : CGI 14N Relay 110V DC, Designation of relay : CGI 14N, Numerical Non - communicable FP IDMTL+INST 3O/C+ 1E/F Relay flush mounted type, Over current IDMLT setting - 5% to 200% of CT secondary, Earth fault IDMTL setting - 5% to 200% of CT secondary, instsntanious Over current setting 50-1600%in step of 1% complete all as specified and directed by Engineer in Charge. (A) Having the following additional facilities :- (i) Trip ckt supervision (ii) Disturbance recorder (iii) Event log with date and time. Make :- CG /Schneider/L&T/HAVELLS
S&F in replacement for flash over carbon cleaning kit consisting of CRCA super gasket remover-400ML- 02 Nos, CRC LECTRA CLEAN-400 ML-04 Nos for cleaning of carbon deposited due to flash over on bus bars and insulators complete all as specified and directed by Engineer-in-Charge
S&F in replacement for moisture removing cum protection Kit consisting of CRC-2-26-500ML 06 Nos, LECTRA CLEAN-400 ML 06 Nos complete all as specified and directed by Engineer-in-Charge
S&F in replacement for CT/PT/PCB protection Kit consisting of CRC Plastic-70-400ML- 12 Nos, which is moisture and acid proof protects equipment from moisture and acidic fumes complete all as specified and directed by Engineer-in-Charge
M & L for inspecting, testing and commissioning of SF-6 breaker including charging with approved gas if required old fault items replace with new at 66 KV Grid Sub Station complete all as specified and directed by Engineer-in-Charge
M & L for inspecting, repairs, testing and commissioning of all C&R panel relay complete all as specified and directed by Engineer-in-Charge including the followings :- (a) IDMT Relay. (b) Master Trip Relay. (c) All other miscellaneous relay including checking of all wiring circuit. (d) Tripping Mechanism as per trnasformer protection requirement.
S&F for Isolating 66 KV BUS system, temporary earth connection of BUS system removing old paint from surface of pole structure & LA tower by scraping, rubbing and making good surface for painting for two coats of aluminium paint on rusted pealed out surface after cleaning all 66 KV GRID Structure complete as specified and directed.
Material and labour for repair to brocken platform of transformers of any size, top brick surface of platform shall be finish with 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate and sides shall be plastered in CM (1:6), 15 mm thick, exposed surface shall be applied with 2 coats of white wash omplete all as specified and directed by Engineer-in-Charge ---------------------------------------------------------------------------------------------------- Note : A sum of Rs. 6,83,487.00 will be deducted on account of credit for taken down material. Please refer details on Srl Page No. 28 (Schedule of Credit) of Tender documents.
Vinod Kumar Bajaj
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .