| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-Finance Offer lowest bid therefore provisional order issued | |
| 2 | L2₹33.6 L+₹8.6 L (34.4%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹33.7 L+₹8.7 L (34.8%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹33.8 L+₹8.7 L (34.9%)Rejected-Finance | L4 | Rejected-Finance that the bid is not L1 | |
| 5 | L5₹36.4 L+₹11.4 L (45.4%)Rejected-Finance | L5 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
18 Feb 2022, 1:00 pmClosed
EE I KNHED PW Dte.
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Covid Spracific infrastructure in Proposed COVID HDU Medicine at Fifth floor CB Building under R G KAR MCH SITC of Air Condition Unit
2022_WBPWD_364393_1
WBPWD/EE/KNHED/NIQ-123/2021-22
Open Tender
A/C ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹60,000
3 Mar 2022
3 Feb 2022
21 Feb 2022
5 Feb 2022
18 Feb 2022
5 Feb 2022
Amount
Supply of Ceiling Mounted Ductable DX type Air Conditioning Unit with 132000 btu/hr Cooling capacity,4400 CFM Air Flow, with 2 nos, Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 11.0 TR nominal capacity with R-410A/R407C Refrigerant. (Make-Hitachi/O-General /Carrier/Voltas/Daikin/Blue Star).
Supply of Ceiling Mounted Ductable DX type Air Conditioning Unit with 198000 btu/hr Cooling capacity, 6600 CFM Air Flow, with 3 Nos.Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 16.5 TR nominal capacity with R-410A/R407C Refrigerant. (Make-Hitachi/O-General /Carrier/Voltas/Daikin/Blue Star).
Supply of Ceiling Mounted Ductable DX type Air Conditioning Unit with 66000 btu/hr Cooling capacity, 2200 CFM Air Flow, with 1 Nos.Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 5.5 TR nominal capacity with R-410A/R407C Refrigerant. (Make-Hitachi/O-General /Carrier/Voltas/Daikin/Blue Star).
Supply and fixing of UVC EMIITTER for the above fan's for prevention of fungus , The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995)
Installation, Testing & Commissioning of the above Air Conditioning systems with all necessary accessiores for hanging Indoor & Outdoor Units a) For 16.5 TR Ductable Units.
b) For 11.0 TR Ductable Units.
c) For 5.5 TR Ductable Units.
S&F of Copper refrigeration pipe line for liquid and suction line with hard drawn copper piping with supports & Brackets a) Cu. Pipes Suction line dia 15.88 mm.
b) Cu.HD Pipes Suction line dia 22.2 mm with 13mm thick nitrile insulation.
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. a) 3 core x 2.5 mm² (Make- Polycab/ Haavells/KEI/RR cable/ Gloster).
b) 4 core x 2.5 mm² (Make- Polycab/ Haavells /KEI / RR cable/ Gloster).
Supply & fixing of dia UPVC drain pipes with all necessary hanging arrangements & 9mm Heat Retardant Thermal insulutaion. a) Dia 32mm
b) Dia 25mm
SITC of Site Fabricated G.I Sheet Metal Square Air Duct complete with Angle, Fastner, supports, dampers etc. as per specifications & site requirement. a) For 24 SWG
b) For 22 SWG
Supply and fixing Heat Retardant closed cell Class'O' 9mm thk Nitrile Rubber insulation inside Supply Air duct.
Supply and fixing Heat Retardant closed cell Class'O' 9mm thk Nitrile Rubber insulation with AI Foil Faced Outside Supply Air duct.
Supply & Fixing of Liner type AI Powder Coated Continuous Grill with VCD for Supply Air.
Supply & Fixing of Liner type AI Powder Coated Continuous Grill without VCD for Return Air.
Supply and Fixing of Fresh air Volume Control Damper.
Supply and Fixing of Non-Return Type Flow Control Damper .
Supply & Fixing of Fusiable Link Fire Damper,Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995),with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed for 16.5 Tr & 11.0 Tr
Supply & Fixing of Fusiable Link Fire Damper,Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995),with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed for 5.5 Tr
Supply and Fixing of Motorized Volume Control Damper.
Civil Work like- Wall Cutting, Wall finishing painting etc for this job as required as per direction of EIC.
Schafolding & lifting, Shifting of Ac maching IDU, ODU & Exhaust fan.
Providing and fixing fire retardant nonporous double layer flexible connection between IDU and duct for 16.5 Tr & 11.0 Tr Ductable.
Providing and fixing fire retardant nonporous double layer flexible connection between IDU and duct for 5.5 Tr Ductable.
SITC of heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
Supply & Fixing of Fresh Air Damper with Bird Screen as per direction of E.I.C (Make:Primier/Air Kolkata/Air Primier/AFI).
Supplying, fabrication & fixing 4 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame table type for installation of 16.5 Tr & 11.0 Tr Ductable AC incl. drilling 2 nos holes in each channel. fabricated with 4 Nos.Baricated the same for maintenance horizontal angle of 50 mm x 50 mm x 6 mm Inscl Platform as per direction of E.I.C.. Area of Platform 9mtr x 1.8mtr for Placing the Exhaust Units including scaffolding charges.
Supplying, fabrication & fixing 4 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame table type for installation of 5.5 Tr Ductable AC incl. drilling 2 nos holes in each channel. fabricated with 4 Nos.Baricated the same for maintenance horizontal angle of 50 mm x 50 mm x 6 mm Inscl Platform as per direction of E.I.C.. Area of Platform 9mtr x 1.8mtr for Placing the Exhaust Units including scaffolding charges.
Supply & Fixing of IDU & Duct Covered with 3mm thick ACP Board (Make:Aludecor/Protap Bond) Coplete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Chrages for Trap door with ACP Board (Make:Aludecor/Protap Bond)Coplete with linkages, levers, fittings, supports, all accessories for IDU Maintenance make with ACP Board as per direction of E.I.C.
(Rate should be quotated including all taxes and duties)
S.R. REFRIGERATION AND APPLIANCES
Lyric International
REFRIGERATION AND AIRCONDITIONING CORPORATION
GITANJALI ELECTRONICS AND ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .