Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹83.7 LAccepted-AOC 39 PRATAPGANJ PETH SATARA | ₹83.7 L | 1 | Accepted-AOC Accept |
| 2 | 2₹85.8 LRejected-Finance 714 714 PLOT NO 19 FLAT NO 102 AYODHYANAGAR PUNE 411007 | PUNE | MAHARASHTRA | 411007 | ₹85.8 L | 2 | Rejected-Finance Reject |
| 3 | 3₹94.4 LRejected-Finance | ₹94.4 L | 3 | Rejected-Finance Reject |
| 4 | Not Admitted-Fee/PreQual/Technical SATARA | MAHARASHTRA | 412801 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
24 Nov 2025, 5:00 pmClosed
Additional Chief Executive Officer Z P Satara
Additional Chief Executive Officer Z P Satara
IMPROVEMENT OF SHIRWAL PALASHI VADGAON ROAD ODR-8(BHAG GAWADEWADI PHATA TO PALASHI) ch1/800 to 2/500
2025_SATAR_1246655_23
Works/North/A-8/3054/08/25-26
Open Tender
Civil Works
180 days
IMPROVEMENT OF SHIRWAL PALASHI VADGAON ROAD ODR-8(
open
9 documents required · 9 mandatory
₹5,000
₹1.1 L
19 Feb 2026
17 Nov 2025
25 Nov 2025
17 Nov 2025
24 Nov 2025
17 Nov 2025
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means Item / Page No : 10 / 23 Specification No : MORTH-301 Spec. Page No : 45-53 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.
Picking the road surface including sectioning, excetra complete. (Water bound macadam road surface) Item / Page No : 32 / 25 Specification No : MORTH-404 Spec. Page No : ---
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification inciuding spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening / binding material to fill the interstices of coarse aggregate, watering and compacting with Vibratory roller to the required density. - By Mechanical Means - Grading I Using Screening type-A (13.2 milimetre Aggregate) Item / Page No : 18 / 29 Specification No : MORTH-401, 402, 404, 902, 112 Spec. Page No : 109-111, 112-116, 121-129, 417-421, 19-21
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for concrete road including laying plastic sheet of 125 micron thickness with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen (excluding reinforcement) with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) excetra complete. Item / Page No : 22 / 44 Specification No : MORTH 602 Spec. Page No : --- Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete. Item / Page No : 29a / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete. Item / Page No : 30 / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete. Item / Page No : 31 / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing off unsuitable or excess stuff as directed all sorts of soils. Item / Page No : 18 / 24 Specification No : MORTH-301, 309 Spec. Page No : 45-53, 85-89 Additional Specifications : 1. The useful excavated material shall be utilised as directed by the Engineer in-charge. 2. The rate of contract shall be for one cubic metre instead of one running metre as mentioned in the specification.
Cutting of branches of trees and shrubs from the road way or within right of way including disposal of wood and leaves to suitable location, excetra complete. Item / Page No : 16 / 76 Additional Specifications : The work shall be carried out as per the instructions of Engineer In-Charge.
Providing and laying cement concrete pipe confirming to Indian Standard 458:2003 non pressure class-2 of 600 milimetre diameter in proper line, level and slope including providng and fixing collars in cement mortar 1:2 and curing, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 9 / 81 Specification No : CD.7 Spec. Page No : 162
Providing and laying cement concrete pipe confirming to Indian Standard 458:2003 non pressure class-2 of 900 milimetre diameter in proper line, level and slope including providng and fixing collars in cement mortar 1:2 and curing, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 11 / 81 Specification No : CD.7 Spec. Page No : 162
Providing and fixing reinforcement cement concrete 200 metre stones as per Indian Road Congress standard including fixing in standard size cement concrete 1:4:8 block including curing, painting, lettering, excetra completed. Item / Page No : 2a / 46 Specification No : MORTH-807 Spec. Page No : ---
Providing and fixing 1:2:4 ordinary kilometre stones as per Indian Road Congress standard including fixing in standard size cement concrete 1:4:8 block including curing, painting, lettering, excetra completed. Item / Page No : 2b / 46 Specification No : MORTH-807 Spec. Page No : ---
Painting line, dashes, arrows, excetra on roads in two coats on new work with ready mixed road marking paint confirming to Indian Standard : 164 on bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control. - Over 10 centimetre wide on new surface. Item / Page No : 8a / 46 Specification No : MORTH-202 Spec. Page No : 39-42
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 milimetre diameter made out of 1.5 milimetre aluminum sheet bonded with white retro-reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals,arrow as per IRC:67-2012 Table number 8.3 Supported with back support frame 25mm X 25mm X 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 milimetre X 65 milimetre X 6 milimetre, 3.45 metre long, duly painted with with flat oil paint having alternate black and white bands of 25 centimetre width including galvanised iron fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Item / Page No : 27a / 52 Specification No : MoRTH-806 Spec. Page No : ---
Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and Abstrone Butadyne Styrine moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kilogram tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of Ministry of Road Transport and Highways Circular number RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 milimetre, 100 milimetre and 102 +/- 2 milimetre and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 milimetre and height not less than 30+/- 2 milimetre) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retroreflectance of the reflecting panel, to the Engineer Item / Page No : 9 / 47 Specification No : MORTH-202 Spec. Page No : 39-42
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual Means Item / Page No : 1 / 153 Specification No : Bd.A.1 Spec. Page No : 259 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Manual Means Item / Page No : 5 / 153 Specification No : Bd.A.2 Spec. Page No : 259 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.
Providing cast in situ / ready mix M-10 grade cement concrete for head walls of cross drainage work / retaining walls excetra including necessary form work, compaction, finishing and curing excetra complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) without Supervisory Control and Data Aquisition with Natural / VSI standard Artificial Sand) (using ARTIFICIAL SAND). Item / Page No : 28 / 83 Specification No : CD.8 Spec. Page No : 163 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting
Metric Ton
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.50 MB
b1.pdf
Tender Documents • 4.13 MB
BOQ_2149880.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid