| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.9 LAccepted-AOC B 1 2 MAHESH NAGAR AMBALA CANTT 133001 HRY | AMBALA CANTT | AMBALA | HARYANA | 133001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹24.4 L+₹5.5 L (28.9%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹26.6 L+₹7.6 L (40.2%)Rejected-Finance HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance other than L-1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-09 (ATC) AT R and O FLIGHT UNDER GE (SOUTH) UDHAMPUR
2020_MES_358326_1
CWE/U(S)-52/2020-21
Open Tender
Civil Works
Item Rate
180 days
Udhampur
AS PER TENDR
7 documents required · 7 mandatory
₹500
GE (South) Udhampur
₹50,000
Yes
4 Nov 2020
4 Jul 2020
24 Sept 2020
4 Jul 2020
22 Sept 2020
10 Sept 2020
60 days
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 1 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Accoustic proof (noise absorption 0.95 NRC as per ASTM 423.90 fire rating 25 (A grade) ASTM - E - 84 weather resistance with antifungal) 100% mineral fibre board size 600mm x 600mm and 16mm thick fix in ceiling including GI powder coated snap grid frame work & including Gl suspension hanging wires at desired distance, complete all as specified and as directed by Engr - in - Charge Make: V-Next of Visaka or equivalent as approved by GE
10mm thick perforated gypsum boards as in paneling as approved, moisture resistant, including intermediate, perimeter channel wall channel, along with nuts and bolts connecting plates for gypsum boards, dry wall screws soffits cleats, panelling section, rowel plugs fixtures and screws and applying two coats of emulsion paint over a coat primer on exposed surface, complete all as specified and as directed by Engr - in - Charge. Note: (a) Design of paneling board as approved by Engr - in - Charge Make: Full tone of Gyproc or equivalent of makes mentioned in PS.
Stainless steel pipes as in framing for railing including fixing arrangement of 10mm thick toughened glass on frame as per site requirement conforming to Gde 304, complete all as specified and as directed by Engr - in - charge. (Note: Toughened glass will be measured and paid separatly)
10mm thick toughened glass as in railing, partition fixed type including necessary fixings such as silicon gell or other fixing clips clamps, complete all as specified and as directed by Engr - in - charge
Powder coated (15 micron of approved colour) Aluminum anodised channel double glass door with 6 mm thick toughened glass, hydraulic door closer, locking arrangement with lock and keys with the following details: - (i) Frame section 65 x 44 x 1.5mm thick with suitable locking arrangement with lock (Make: Godrej) 4 lever, 6mm thick toughened glass, 5mm thick aluminium push plate, hydraulic door closer-01 No, handles, pivet with standard floor spring and pivot on top frame, aluminium tower bolts 300 mm long-01 No, glazing clips, rubber packing for locking purpose with aluminium snap beading screws, hold fast complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing two layered fixed structural glazing using aluminum frame work in ATC room windows. The sections of aluminum members and glass will be as under :- (a) Powder coated aluminum section of size 101.2 mm x 57.0 mm and thickness of aluminum sheet is 2.80 mm. (b) Powder coated aluminum pressure plate section as per requirement (c) Powder coated aluminum cover plate section as per requirement (d) 6mm thick tinted toughened glass (tint shall be approved by GE) on outer side with 12mm air gap and 6mm clear toughened glass (inside) spaced apart with a spacer bar and hermetically sealed with a primary and secondary sealant to form a single unit . (e) Applying silicon sealant all around glass and windows (f) Float glass shall be of Modiguard / Saint Gobain / Gloverbel and also tinted glass shall be Modiguard / Saint Gobain / Gloverbel and epithelium rubber gasket shall be provided as directed.The insulated glass unit shall be of AIS glass solutions Ltd / Saint Gobain or equivalent approved by GE. Note:- The glazing work shall be got carried out by specialist agency, any civil work required for fixing shall be considered to be included in rate quoted by tenderer. Make of Aluminium sections : Jindal/Hindalco/makes specified in PS.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Glazed coloured ceramic jointfree/rectified tiles 300x200mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering /backing coat in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Cabinet cupboard in required size at site made out 18mm thick one side decorative lamination sheet consisting of carcass 18mm thick PVC sheet & provn of shutters made out of 18mm thick one side decoartive laminated PVC sheet all required brackets fixed with screws etc. the panels shall be fabricated using adhesives and CP screws where ever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per make and specification mention as per drawing approved by Engr - in - Charge and Colur as approved by GE complete all as directed. (Make : Rajshree or equivalent approved )
PVC molded steel catcher of superior quality , complete all as specified and directed.
100 mm long Stainless steel alloy handles decorative type, complete all as specified and directed.
75mm butt hinges ,medium weight ,cold rolled mild steel all as complete all as specified and directed.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping, holdfst block etc including necessary formwork complete all as specified and as directed by Engr-in-harge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty (JK Birla) including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (double charged) of 10mm thick any colour (area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, joint free, coloured ceramic tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , complete all as specified and as directed by Engr-in-Charge.
Applying two coats of acrylic weather proof exterior emulsion paint on walls, cornices in camouflage pattern over and including one coat (1 mm thick) birla wall care putty including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified with complete removing. Make : JK Birla or equivalent as specified in PS
Heavy duty coloured vitrified tiles (for external application) 10 mm thick Square/rectangular tiles area of each tile exceeding 0.09 Sqm but not exceeding 0.36 Sqm as in floors set and jointed in neat cement slurry laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, and pointed in coloured cement to match the surface complete all as specifed and as directed. Make : Somany (Durastone) or equivalent in performance of makes as specified in particular specifications. Note : Colour of the tiles shall be as approved by GE.
Demolition of cement concrete (unreinforced) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as pecified and as directed by Engr-in-Charge.
Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200m & n exc 250m., complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm, provide 25mm thick PCC 1:2:4 type B-1 (using 12.5 mm graded crushed stone aggregates) as in level course, provide 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately), Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade VG-20 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument VG-20 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair. (ISI marked)
Taking down 15 mm Bore steel tubing and connections including all fittings and removing from store, complete all as specified and as directed.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light /fan/ bell controlled by one switch with modular metal flush box suitable for module concealed on walls,cover plate with frame for mounting of switches, socket outlet, regulator etc suitable for modular type , fixed with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 42 above but one 3/5 pin 10 Amp socket outlet on independent board .
Description all as per item No 42 above but one 3/5 pin 10 Amp socket outlet on the same board with other switch.
Description all asper item No 42 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all asper item No 42 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Modular switch single pole one way 10 Amps 1 module type complete all as specified and directed by Engr- in-charge
Modular switch single pole one way 20 Amps 1 module type complete all as specified and directed by Engr- in-charge
Modular socket outlet, 2 in 1, 3 pin, 10 Amp flush type 2 module type, complete all as specified and as directed by Engr-in-Charge.
Modular socket outlet, 2 in 1, 3 pin, 20 Amp flush type 2 module type, complete all as specified and as directed by Engr-in-Charge.
Modular bell push single pole one way 10 Amps 1 module type complete all as specified and directed by Engr- in-charge
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Taking down carefully existing ceilling/exaust fan any type sweep and removing fan blade including cleaning all dust particle and filling cavities with filler material, oiling, greasing including painting fan with blade complete one coat of synthetic enamel white paint by spraying and assemble the same along with all fixing connecting accessories and fixing the same position along with all new electrical wire connection complete all as specified and as directed by Engr-in-Charge.
36 watt 2'x2' LED SLIM PANEL- 565 mmX565 mm ,Recess mounted LED slim luminaire, with complete diffuser ceiling light with extruded aluminium housing, and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Wipro cat Pt No CRCO10R038HP57GL1/ Crompton Cat Pt No LCPL 36 CDL (2x2) - 36 W Aura I LED or equivalent in performance of makes as specified in particular specifications.
Siim linear LED tube light fixture 18 Watt , 4 feet white complete, making all connection using 1.5 sqmm copper conductor multistranded PVC insulated 3 core flexible cable in white colour from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and as directed. Make : Crompton Trim Linea Cat Pt No LCTL-18-CDL Or Equivalent make in HPL /Havells.
9 watt LED Lightening Fixture (Mirror Light) with full base environmental acting as a heat sink with closed back, isolated driver, system efficiency ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6000K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multistrand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge. Make – Havells Cat Pt No LHEXBLP7IN1W009, SYSKA Cat Part No. SSK-T5-9W or Equivalent in Bajaj/Philips/Surya/CG.
Bulk Head Light 9/10 watt LED energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge. Make – Syska LED Cat Part No. SSK-BH-9W/ Havells Cat Part No. LHEOAOP7UZ6W010/ Wipro/HPL or equivalent in performance of makes as specified in particular specifications.
10 watt LED Stud type landscape lights for stair wel/corridors / walkway with complete making all connection using 1.5 sqmm copper conductor multistard PVC Insulated 3 core flexble cable complete all as per the directions of Engg - in - Charge. Make- Crompton Stud cat pt - LBHP - 10 CDL or equivalent make in Havells / Phillips
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge. Makes: Legrand/ HPL/Indo asian.
VTPN MCCB DD- Double Door (Including 63 Amp MCCB) 16 KA (as incommer) 4 way IP- 43 protection all as specified & directed including all PCC & cementing work for installation of VTPN DB to Wall Make - Indonsian cat part No 811870 equivalent in havels /Legrand.
MCB SP, 6 to 32 Amps, 'B' series 10 KA 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 'B' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
LED street light fitting as 45 Watt, New generation energy saving & environmental friendly long life versatile pressure dia-cast aluminum IP66 with acrylic, with heat resistant toughened glass, Corrosion resistant complete making a connection with MCB SPN 16 A, 10KA alongwith MCB Box enclosure , complete all as per the directions of Engg.in - Charpe. Make- Crompton Nexus Cap Pt No. LSTP - 45 - CDL or equivalent make in Philips / Havels.
Street light bracket complete made of GI pipe of suitable size of 40 mm dia, medium grade 1.2 m long bent to shape as per te requirement with MS flat iron clamps with nuts , bolts, washers including grouting the same with wall/ pole including taking out old bracket with fitting all as specified and directed by Engr- in-Charge.
AC in hi wall split unit air conditioner reversible type five star rating indoor and outdoor unit complete with cordless remote control unit and with built air ionise and plasma filter for better indoor air quality capacity 2 Ton with standard assessores induding MS framework for installation of outer wall side, including making required hole in wall for passing of cooling pipe/ cable and making good damaged portion of wall/ floor/ roof in CM 1:4 complete as directed. Make : Daikin/ Carrier/ Voltas/ York.
Voltage stabilizer for automatic operation, single phase copper wiring naturally air cooled indoor type & designed for input votage 110 to 270 V output voltage 230 V. With accuracy ( + ) 2.5% and capacity 5KVA . Make : V-Guard/ Electricfield/ Bajaj.
SINGH CONST CO
khajuria builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .