| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹32.5 L+₹3.5 L (12.0%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.6 L+₹6.6 L (22.8%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.7 L+₹11.7 L (40.5%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
24 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)BHANDUP
GE(NW)BHANDUP,MUMBAI
ADDN/ALTN TO WINDOWS OF NS 175 , RAIN BEATING WALL OF BLDG NO NS-128 (SH 47) , WORKERS CHANGING ROOM AT MO(MB) GHATKOPAR
2020_MES_356822_1
8838/B
Open Tender
Civil Works
Item Rate
184 days
GHATKOPAR
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat a(i)
9 documents required · 9 mandatory
₹500
GE(NW)BHANDUP
₹87,000
17 Oct 2020
29 Jun 2020
27 Jul 2020
29 Jun 2020
24 Jul 2020
11 Jul 2020
30 Jun 2020 - 6 Jul 2020
60 days
Amount
Taking down chowkats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm with shutters (without taking off shutters from the frames) complete all as specified and directed
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in jambs, pillars, door and windows-cill, cooking platform , jambs, wash basin platform and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting of oval shape for fixing of counter wash hand basin etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
S&F aluminium section in doors / windows /ventilators sliding or openable or any type , powder coated in colour (Thickness of powder coating not less than 50 micron)(medium weight of series 'B') or as section directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including necessary pvc or rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet and all necessary fittings complete, screws, lock,plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes :- (a)Weight of aluminium sections shall only be measured. (b) The rate quoted shall be deemed to inclusive of necessary rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet
S&F aluminium anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed.
Supply only aluminium wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick walls, RCC pillars, beams, purlins etc and finishing the surface even and smooth complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
Supply only integral water proofing compound.
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls, chajjas applying two coats of 100% anti fungal weather resistant acrylic emulsion paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying two coats of Dr fixit rain coat over one coat of Dr fixit primer all as spd and directed by Engr-in-Charge
M&L for Preparation of New Plastered surfaces of wall and applying two coats of Dr fixit rain coat over( of Shade/colour as directed by E-in-C) one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
M&L for preparation of surfaces and applying oil bound bitumin primer over the roof surfaces @ 0.40 lit per sqm confirming to IS code , manufactrured by the same agency as that of APP with density of 0.87-0.89 KG/ lit at 25 degree C prepared dry roof surfaces for filling the voids and to receive water proofing membrane of weight not less than 3.6 Kg per sqm on roof slab and on parapet wall and mumty portion reinforced with non wooven polyester matt all as per manufacturer's instructions and zonal specification and as directed by Engr-in-Charge.
M&L for solar reflective bituminous aluminium paint @ 0.10 Kg per Sqm over membrane surfaces as in roof treatment complete all as specified
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
Dismantling carefully reinforced cement concrete work (including cutting of the reinforcement as required to facilitate dismantling) with low Impact Hammer / Breaker without dismantling the structure of any description and in any position not otherwise specifically provided for, cleaning and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. And brushing neat cement slurry with 3.0 kg of cement per sq. metre
M&L for 100 mm thick Provding PCC 1:2:4 Type B-2( 40mm graded aggregate) as in flooring etc complete all as specified and directed.
M&L for 100 mm thick Provding PCC 1:4:8 Type D2 40mm greded aggregate) as in sub base etc completeall as specified and directed.
M&L for non skid ceramic tiles 7 to8 mm thick ( square/ rectangular ) area of each tiles exc 0.11 sqm but not exc 0.18 sqm in floors etc . Set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick in screed bed in CM 1:6 all as spd .
M&L for 20 to 25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M & L for Providing and injucting chemical emulsion for post constructional Anti Termite Treatment along with external wall where the apron is not provided using chemical emulsion at the rate of 7.50 litre of emulsion per sqm of the vertical surfaces of the sub structure to the depth of 300mm all as spd.
M & L for treatment of soil under excisting floor using emulsion @ one ltr per hole , 300 mm apartincl drilling and plugging 12mm dia holes with cement mortar 1:2 to match the excisting floor all as spd.
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, of with and including chromium plated brass screws etc complete all as specified and directed. Make:Prayag polymers Pvt Ltd or equivalent
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller one coat of oil bound distemper including application of putty for smooth finish.etc complete all as specified and directed.
Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular steel sunk box having thickness not less than 2 mm including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza)
All as per srl item No 6 above but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per srl item No 6 above but for 5 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6/5 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for switch modular one way 15/20 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
M&L for submain wiring in and including PVC conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 4 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 16 to 40 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing t with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: philips / Havells /CG, Tecnocomercially equivalent in Luccar etc Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
DWARKESH STRUCT-CON
Vijay Enterprises
M/s Qureshi Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .