| Sl No | Description | Qty | Unit | Pallab Chetia L2 | Sri Satya Changmai L1 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material. I) In Ordinary Soil
B. Mechanical means.
ii) Depth up to 3.00 m (with dewatering) | 109.04 | Cum | 80.23 ₹8,748.36 Lowest | 84.23 ₹9,184.52 |
| 2.00 | Bored cast-in-situ M 35 grade RCC pile excluding reinforcement complete as per drawing and Technical Specifications and removal of excavated earth with all lead and lift up to 1000 m. Pile diameter = 1200 mm | 180 | Metre | 15,122.79 ₹27,22,102.2 Lowest | 15,877.42 ₹28,57,935.6 |
| 3.00 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications.
a) Initial load test (Safe load = 160 t | 240 | MT | 372.9 ₹89,496 Lowest | 391.51 ₹93,962.4 |
| 4.00 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications.
b) Routine Load Test of 2x160x2.50
2 Nos. test for piles upto 50 Nos. | 400 | MT | 372.9 ₹1,49,160 Lowest | 391.51 ₹1,56,604 |
| 5.00 | Pile integrity test of piles by using pile driving analyser or equivalent as approved by the E-IN-C and detail specification . Test to be carried out by an approved reputed agency including all incidental works. | 8 | each | 2,350.4 ₹18,803.2 Lowest | 2,467.68 ₹19,741.44 |
| 6.00 | Cement concrete for reinforcement concrete in pile cap complete as per drawing and technical specifications. D. RCC grade M - 35
i) Using concrete mixer | 159.73 | Cum | 11,000 ₹17,57,052 | 8,056.75 ₹12,86,920.79 Lowest |
| 7.00 | Levelling course for Pile cap
Providing and lying of PCC M - 15 levelling course 100 mm thick below the pile cap. as per drawing and technical specifications. | 9.43 | Cum | 5,821.76 ₹54,922.48 Lowest | 6,112.27 ₹57,663.16 |
| 8.00 | Supplying, fitting and placing uncoated TMT Bar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 45.02 | MT | 64,120.72 ₹28,86,714.81 Lowest | 67,320.34 ₹30,30,761.71 |
| 9.00 | Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications.
(N) Without plasticiser
H) a) RCC Grade M 35
a) Height up to 5.0 m
Case-I : Using Concrete Mixer | 52.53 | Cum | 11,000 ₹5,77,863 | 8,521.82 ₹4,47,676.77 Lowest |
| 10.00 | Supplying, fitting and placing TMT bars reinforcement in substructure complete as per drawing and Technical Specifications. b) (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 11.2 | MT | 78,000 ₹8,73,600 | 67,481.69 ₹7,55,794.93 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
30 Dec 2025, 2:00 pmClosed
CE (EAP) PWRD, Fatasil Ambari
O/o the CE(EAP) PWRD, Fatasil Ambari
Construction of Bridge in Lakhimpur District i) Br. No. 5/1 on Singia to Bobindapur
2025_PWRDW_49121_11
EAP/ARRBP eCF No 720769/7
Open Tender
Civil Works - Bridges
Item Rate
540 days
Lakhimpur District
Please refer tender document
7 documents required · 7 mandatory
₹4,000
₹3.5 L
Yes
O/o the CE (EAP) PWRD, Fatasil Ambari
30 May 2026
10 Dec 2025
30 Dec 2025
10 Dec 2025
30 Dec 2025
10 Dec 2025
10 Dec 2025 - 17 Dec 2025
17 Dec 2025
Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material. I) In Ordinary Soil B. Mechanical means. ii) Depth up to 3.00 m (with dewatering)
Bored cast-in-situ M 35 grade RCC pile excluding reinforcement complete as per drawing and Technical Specifications and removal of excavated earth with all lead and lift up to 1000 m. Pile diameter = 1200 mm
Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications. a) Initial load test (Safe load = 160 t
Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications. b) Routine Load Test of 2x160x2.50 2 Nos. test for piles upto 50 Nos.
Cement concrete for reinforcement concrete in pile cap complete as per drawing and technical specifications. D. RCC grade M - 35 i) Using concrete mixer
Levelling course for Pile cap Providing and lying of PCC M - 15 levelling course 100 mm thick below the pile cap. as per drawing and technical specifications.
Supplying, fitting and placing uncoated TMT Bar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/ Reinforced Cement Concrete in substru
Supplying, fitting and placing TMT bars reinforcement in substructure complete as per drawing and Technical Specifications. b) (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainlesssteel matting surfaces, complete assembly to be of cast steel/fabricated structural steel, meatal and elastomer elements to be as per IRC:83 part-I &II respectively and parts conforming to BS:5400, complete as per drawing and approved technical specification.
cture complete as per Drawing and Technical Specifications. (N) Without plasticiser H) a) RCC Grade M 35 a) Height up to 5.0 m Case-I : Using Concrete Mixer
Furnishing and placing reinforcement / prestressed cement concrete in super structure as per drawing and technical specifications. (N) Without Plasticiser D. RCC/ PSC grade M - 35 Case I : Using concrete mixer For T beam and slab, 1) Height up to 5.0 m
Supplying , fitting and placing TMT bar reinforcement complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (a) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2
Providing Strip Seal Expansion Joint to cater movement of +70mm as per drawing.
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications.
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications. Stone/Boulder
Furnishing and placing reinforcement / prestressed cement concrete in super structure as per drawing and technical specifications. (N) Without Plasticiser E. RCC Grade M-40, For T beam and slab 1) Height up to 5.0 m
Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material . I) In Ordinary Soil B. Mechanical means. i) Depth up to 3.00 m (with dewatering)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. I. Without plasticiser A. PCC Grade M15
Supplying, fitting and placing uncoated TMT Bar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. I. Without plasticiser G RCC Grade M30 (i) Using Concrete Mixer
Supplying, fitting and placing TMT bars reinforcement in substructure complete as per drawing and Technical Specifications b) (i) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification.
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification. A)By Mix in Place Method
Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications. H) a) RCC Grade M 35 I) Height up to 5.0 m Case-I : Using Concrete Mixer
WBM Grading 2 Using stone screening Type-B 11.2 mm for Gr.II Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification . Manual means
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification complete including carriage. Including Edge block/ Edge restraints
Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification. 600mm equilateral triangle
Implementation of Enviromental and Social Management Plan -Soil quality monitoring at 3 locations for 3 seasons for 2 consecutive years (3x3 Season) (Construction Stage) (i)Br.No. 5/1 Singia to Bobindapur
Implementation of Enviromental and Social Management Plan -Air quality monitoring at 3 locations for 2 seasons for 1 year. (3x2 Season x 1 Years) = 6 Nos. of samples (operation Stage) (i)Br.No. 5/1 Singia to Bobindapur
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.00 MB
LOT.pdf
Additional Documents • 0.23 MB
LOF.pdf
Additional Documents • 0.14 MB
A1.pdf
Additional Documents • 0.58 MB
sbd_lak31B.pdf
Tender Documents • 2.73 MB
BOQ_78057.xls
BOQ • 0.30 MB
dwgsLak_31B.pdf
Additional Documents • 5.42 MB
esmp_LAk31B.pdf
Additional Documents • 2.01 MB
Technical_specification_ARRBP.pdf
Additional Documents • 1.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .