Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 256 MUNDHELA KHURD NEW DELHI 73 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Bidder has been disqualified, as the experience certificate submitted by the bidder indicates completion of two similar works valued at INR 111.79 lakhs and INR 20.07 lakhs against the required value of INR 84.33 lakhs each. |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
8 Apr 2026, 3:00 pmClosed
SENIOR MANAGER
CWC RO LUCKNOW
Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
2026_CWC_273066_1
E NIT_CWC/RO-LKO/Engg./25-26/57T
Open Tender
Electrical Works
Percentage
90 days
CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini a
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹3.4 L
17 Jun 2026
25 Mar 2026
9 Apr 2026
25 Mar 2026
8 Apr 2026
25 Mar 2026
CENTRAL WAREHOUSING CORPORATION (A Govt. of India Undertaking)
Sub-Schedule-I E&M DSR 2025
NIT Number CWC/RO-LKO/Engg./25-26/57T
Name of Work Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
NAME OF CONTRACTOR
Sr.No. Name of Work Total Amount (In Rs.) Quoted rates (Above/Below/At par) Rate to be quoted in percentage(%) Quoted % In Words Quoted amount in figure
1 Sub-Schedule-I E&M DSR 2025
TOTAL QUOTED PRICE=
Amount Quoted (In Words)
Note Total CWC estimated Cost for this schedule including Cost Index, labour cess & applicable GST (Rs.) ₹ 1,46,80,051.42
CENTRAL WAREHOUSING CORPORATION (A Govt. of India Undertaking)
Sub-Schedule -II: E&M MR ITEMS
NIT Number CWC/RO-LKO/Engg./25-26/57T
Name of Work Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
NAME OF CONTRACTOR
Sr.No. Name of Work Total Amount (In Rs.) Quoted rates (Above/Below/At par) Rate to be quoted in percentage(%) Quoted % In Words Quoted amount in figure
1 Sub-Schedule -II: E&M MR ITEMS 2221380
TOTAL QUOTED PRICE=
Amount Quoted (In Words)
Note Total CWC estimated Cost for this schedule including Cost Index, labour cess & applicable GST (Rs.) ₹ 22,21,380.00
CENTRAL WAREHOUSING CORPORATION (A Govt. of India Undertaking)
Price Bid ( Summary Sheet)
NIT Number CWC/RO-LKO/Engg./25-26/57T
Name of Work Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
NAME OF CONTRACTOR
Sd.-I SCH_I (E&M DSR 2025)
Sd.-II Sch_II (E&M MR) 2221380
Grand Total (In Figures)
Grand Total (In Words)
CENTRAL WAREHOUSING CORPORATION
(A Govt.of India Undertaking)
SCHEDULE OF QUANTITY
Name of work : Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
Schedule A DSR 2025 based E&M Items
SLNo Description Qty Unit Rate Amount DSR-2025 No.
1 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 Supplying and fixing of following sizes of medium class PVC Conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
3 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block inlcuding connections etc. as required. 1878 Each 104
4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
(a) 6 way, Doble door 73 Each 2390 2.3.1
(b) 8 way, Doble door 70 Each 2773 2.3.2
( c) 12 way, Double door 150 Each 2871 2.3.3
(d) 16 way, Double door 3 Each 3367 2.3.4
5 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
(a) 4 way (4 + 12), Double door 11 Each 4377 2.4.1
6 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
(a) 4 way (4 + 12), Double door 3 Each 7951 2.5.1
7 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" Curve, Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) Single Pole 2254 Each 285 2.10.1
(b) Double Pole 358 Each 696 2.10.3
8 Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
(a) 100 A,30KA,FPMCCB 4 Each 8127 2.2.13
10 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP MCB , in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, tetsing and commissioning etc. as required. 51 Each 1806 2.18
11 Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of Mild Steel at least 2 mm thick, and vitreous enameled white on both sides and with the incription in single red color on front side as required. 30 Each 315
12 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 11 Each 7658
13 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 55 Meter 313
14 Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 70Watt 1293 Each 2299 8.16.1
15 Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 100Watt 139 Each 2467 8.16.3
16 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia 125 Meter 741.57 15.13.1
17 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 80mm dia 20 Meter 1013.57 _ * #,##0.00_ ;_ * \-#,##0.00_ ;_ * "-"??_ ;_ @_ 15.13.2
18 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
(a) Upto 35 sq. mm 125 Meter 47 10.5.1
(b) Above 35 sq. mm and upto 95 sq. mm 20 Meter 72 10.5.2
19 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required.
(a) Upto 35 sq. mm (clamped with 1 mm thick saddle) 549 Meter 64 10.7.1
(b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3 mm MS Flat Clamp) 50 Meter 151 10.7.2
20 Supplying and making end termination with brass compression gland and aluminium lug for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV garde as required.
21 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 11 Each 598
22 Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 250 Watt 14 Each 5969 8.16.6
23 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
(a) Group C 45 Each 1704 1.10.3
24 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 24 Each 659
25 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
(a) Upto 450 mm sweep 5 Each 556 1.50.1
26 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 20 Each 757
27 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. 3 Each 807
28 Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 7 Each 2882 9.1.3
29 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 326 Meter 311 1.14.2
30 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 185 Meter 373 1.12
CENTRAL WAREHOUSING CORPORATION
(A Govt.of India Undertaking)
SCHEDULE OF QUANTITY
Name of work : Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
Schedule A MR based E&M Items
SLNo Description Qty Unit Rate Amount DSR No./MR
1 Supply and fixing of 20 mm dia flexible corrugated metal/GI conduit as required 939 Meter 35 MR
2 Supply, installation, testing and commissioning of LED well glass fixture with following wattage rating and as per technical specifications attached, including accessories for support on wall, bracket, truss, or suitable hanging arrangement upto 1 meters, and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge. . Make : Havells Jeta Iris/Crompton/ Bajaj/ Philips or eq. a) 70Watt 446 Each 3874 MR
3 Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 3.5x50sqmm 60 Meter 568 MR
4 Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 4x25sqmm 194 Meter 332 MR
5 Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 4x16sqmm 450 Meter 270 MR
6 Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.(a) 3x10sqmm 30 Meter 194 MR
7 Supply & installation of outdoor stand mounted feeder pillar with 1 no. 32A TPN MCB incomer, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals. 1 Job 32921 MR
8 Lowering of carriage of High Mast Tower and raising the same including necessary fault repair/ maintenance, by operation of winchgear assembly by manual/electro-mechanical means complete as required as per direction of official in charge. 4 Job 2525 MR
9 Supplying of 230 mm sweep 230 volts exhaust/ ventilation fan. As required.Make : Havells, Model : Ventilair DSP 230mm Exhaust Fan or equivalent in Bajaj, crompton as per direction of EIC. 5 each 2056 MR
10 Supply & installation of 18/20 Watt 4 feet LED T8 Tube light (Poly carbonate make) as per required specification and as per instructions of official-in-charge. 33 each 386 MR
11 Supplying, fixing and commissioning of IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Gate light complete with all accessories and connection etc as reqd.Make: Havells, Model: RUBYMINIPT15WLED757PSYMTOPC or equivalent in Bajaj, Crompton as per direction of EIC. 4 each 5787 MR
12 Supply, Installation, Testing and Commissioning Wall Mounted Fan of 400mm sweep on wall with 1.5sqmm wire etc complete suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
(a) 400mm Sweep Wall Mounted Fan make Havells/Crompton/ Bajaj 3 each 3570 MR
13 Supply of PVC insulated/inner sheathed, Copper conductor,LT XLPE cable, 1.1 Kv grade, steel strip armoured as per IS 7098 (part-1)-1988 with up to date amendments, of following size as required (Make: Polycab, havells, Grandley, KEI, RR cable)
(a) 3 X 2.5 Sqmm Copper armoured 410 Meter 199 MR
(b) 3 X 4 Sqmm Copper armoured 130 Meter 274 MR
14 Supplying and fixing following 63 Ampere rating, Triple Pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of official in charge 12 1483 MR
Central Warehousing Corporation (A Govt. of India Undertaking)
REGIONAL OFFICE
Pre-Qualifying (PQ) Proforma: Bidder Information Summary {To be Filled by Bidder in sheet uploaded over portal and then to be submitted along with technical bid}
ENIT NO:CWC/RO-LKO/Engg./25-26/57T
Name of Work :- Electrical upgradation works in godowns at CW Jhansi, Faizabad, Dumariaganj, Hardoi, Naini and Bhadohi.
Name of the Bidder *Mandatory
SL Description Details (filled by Bidder)
See PQC S/n (1) to (4): Appendix-II of NIT
1 Name of the Bidder
1.1 Bidder Address, (registered)
1.2 Bidder Organization ID /CIN in case of Company
1.3 Bidder Telephone number
1.4 Bidder E-mail address
2 Type of Bidder constituent (Organization)
(JV not allowed where estimated cost of work put on Tender is up to Rs. 30 cr)
2.1 Attested copy of documents in support of Bidder Organization Type
(See ITB-Appendix IV clause number 3.2: 1 (b): Organization Details and Appendix-II of NIT: List of documents required in support of Bidder Legal Entity.
2.2 Current List of Directors/Partners: as applicable
3 Name of the person holding the power of attorney for this Bid
3.1 Designation
3.2 Contact details of person holding the power of attorney
3.3 Attested Copy of Power of Attorney to sign & submit the Tender (as per format given in EXHIBIT-III of Appendix-II)
4 Earnest Money Deposit (EMD) of Amount as mentioned in APPENDIX-1 (TIS) through NEFT/RTGS
5.1 PF Registration code number of Bidder
5.2 COPY of PF Registration number of Bidder
6.1 GST Registration code number of Bidder
6.2 COPY of GST Registration number of Bidder
7.1 PAN of the Bidder
7.2 COPY of PAN of Bidder
8.1 Whether Enlisted /Empaneled with CPWD/ MES/ Railway/ PWD/ CWC/any other PSU etc. if any,
8.2 Copy of Enlistment/Empanelment certificate Submitted or Not
9 Whether Bidder is executing or completed any work awarded by CENTRAL WAREHOUSING CORPORATION in Past Three FY Year (FY 2022-23, FY 2023-24 & FY 2024-25) and Current FY 2025-26.
10.1 Affidavit along with this PQ Performa (EXHIBIT-I) on NJS paper signed and submitted after filling necessary details.
10.2 Declaration of near relatives (EXHIBIT-IV) submitted.
Technical Eligibility Criteria:
See PQC S/n (5) in Appendix-II of NIT for details & qualifying limits.
11 Particular Technical Experience w.r.t. Similar Nature of Work:
11.1 Brief of Similar Nature Work Experience-1
I Work order/ contract agreement ref number and date
Ii Name of client issued the work order and completion certificate
iii Completion certificate -ref number and date
iv Total value of work completed (Rs.)
V Stipulated date of completion
vi Actual date of completion
vii If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
viii Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
11.2 Brief of Similar Nature Work Experience-2
I Work order/ contract agreement ref number and date
Ii Name of client issued the work order and completion certificate
iii Completion certificate -ref number and date
iv Total value of work completed (Rs.)
V Stipulated date of completion
vi Actual date of completion
vii If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
viii Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
11.3 Brief of Similar Nature Work Experience-3
I Work order/ contract agreement ref number and date
Ii Name of client issued the work order and completion certificate
iii Completion certificate -ref number and date
iv Total value of work completed (Rs.)
V Stipulated date of completion
vi Actual date of completion
vii If LD is levied: Amount / period of delay for which Liquidity damage is levied by client (if any)
viii Copy of completion/experience certificate of work and Copy of Agreement/Workorder issued by Client is submitted as per format given in EXHIBIT-V or EXHIBIT-VI or EXHIBIT-VII as applicable
See PQC S/n (6) in Appendix-II of NIT for details & qualifying limits.
Information on Financial Capabilities & Turn over
12.1 Annual Financial Turnover-Total Revenue (Income) (as per CA certificate and audited P&L Account)
iii FY 2022 –23
iv FY 2021–22 (only when audited turnover for FY 2024-25 is not available)
12.2 The average of financial turnover for the last three financial years i.e. FY 2024-25, FY 2023-24 and FY 2022-23 Or FY 2021-22 (FY 2021-22 to be referred only when Audited turnover of FY 2024-25 is not available)
1. Tenderers have to fill complete details in Pre-Qualifying Performa (Bidder Information Summary) in sheet uploaded over tender portal.
2. Documents pertaining to the above details should be scanned and uploaded on e-tendering website at the time of on-line tender submission.
3. RTGS/NEFT E-payment Challans with UTR no. duly authenticated by Bank may also be scanned & uploaded along with tender submission.
4. Bidder must refer Tender Information Summary (TIS) in APPENDIX-I, PRE QUALIFICATION CRITERIA (PQC) in (APPENDIX-II) and Tender eligibility criteria as per ITB clause 3 (APPENDIX-IV) appended with NIT before filling this PQ Performa and Affidavit.
5. The PQ Performa EXHIBIT-I along with Its Annexure (Affidavit) enclosed with this Performa is mandatory and must be submitted by the Bidder.
stage.html
html • 0.03 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 5.07 MB
TenderDocument57T.pdf
Tender Documents • 5.05 MB
Pricebid57T.xls
Additional Documents • 0.15 MB
TechBid57T.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .