Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.6 L+₹1,157.25 (0.03%)Rejected-Finance KUTUMB 143 40 VINAYAK NAGAR INDALPUR ROAD NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | UTTAR PRADESH | 211008 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.7 L+₹1.0 L (2.93%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.0 L+₹2.4 L (6.63%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.1 L+₹2.5 L (6.98%)Rejected-Finance 23 47 25D BHAGABARI ROAD ALLAHPUR ALLAHABAD UP | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Addition/alteration cum spl repair to certain bldg of Yamuna Viahr at Old Cantt Prayagraj.
2023_MES_577760_1
8612/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹77,600
Yes
21 Mar 2023
28 Jan 2023
2 Mar 2023
28 Jan 2023
28 Feb 2023
13 Feb 2023
28 Jan 2023 - 4 Feb 2023
Amount
Demolition of Concrete work reinforced as in chajja and similar suspended work, complete all as specified and directed.
Precast reinforced cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs (for manholes covers, kitchen slab etc.), shelves and similar articles with plain faces complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks, old size straight or curved on plan to any radius in half brick walls, built in CM 1:4, complete all as specified and directed.
Brickwork with flyash bricks, old size straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed.
Brickwork with sub class 'B' bricks, old size straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed. [Except brick] Note: Bricks obtained from item No 4 above shall be used.
Dismantling brick tiles any size laid bedded and pointed in any mortor, complete all as specified and directed.
Demolition of mud in roofs any thickness and in any position and leaping over roof terrace, including clening the roof by wire brush, broomi renual dustete, removing the demolished material to a distance exceeding 250 m & not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above starting point, including removing existing roof treatment complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-0 (12.50mm graded stone aggregate), as in levelling course, benching etc., and finished the surface even and rough to receive screed bed, complete all as specified and directed.
10mm thick bedding plaster in CM 1:4, mixed with water proofing compound @3%, over roof slab, finishing the surface even and fair, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed.
Providing water proofing treatment to the roof surface comprising of the following:- (a) Applying one coat of Bitumen primer confirming to IS-3384-1965 @ 0.50 kg per sq.m. (b) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS – 702-1998 for water proofing membrane. (c) Applying of Polymeric water proofing membrane weight not less than 3 kg / sq.m with overlaps and sealed all as specified and directed. (d) Again applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg / sq.m over water proofing membrance. (e) Dusting dry sand @ 0.75 kg per sq.m over water proofing membrane. (f) Fixing of GI pipe spout 50mm of adequate size, complete all as specified and directed.
Cement concrete tiles 250 mm x 250 mm x 25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement and no pigments with and including provision of 15mm thick screed bed in CM 1:4 for laying of tiles, complete all as specified and directed..
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store, removing rubbish off the premises, complete all as specified and directed.
Vitrified ceramic tiles (light shade) 9 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm each, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed or backing in CM 1:6, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, area of each tile shall exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:4, complete all as specified and directed.
Vitrified ceramic tiles (light shade) 9 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm each , in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed or backing in CM 1:6, complete all as specified and directed.
Glazed ceramic premium quality jointfree coloured tiles as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 450mm x 300mm x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing coat of tiles in cement mortar 1:4, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded in any mortar, complete all as specified and directed.
Baroda green Marble flooring work18 to 20 mm thick laid over and including 20mm screed bedding in cement mortar (1:4) (table rubbed and polished) incl steps, jambs, pillars, windowcills, riser ,treads in stair case and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
Baroda green marble slab 18- 20mm thick (in full length one piece) in riser of steps, skirting, dado and pillar laid over and incl 10mm thick plaster in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Granite, 18 to 20mm thick, (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in CM 1:4, complete all as specified and directed.
Rounding to edges of stone slabs any type & description one edge, such as in steps, cooking platform, and othe similar situations, including machine polishing to edge to give high glass finish etc. complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75 mm thick, as in plinth protection including finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site, complete all as specified and directed.
Rendering 15mm thick in CM 1:4, mixed with water proofing compound, on fair faces of brick work or concrete surfaces of walls, finishing the surface even and fair, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound of approved make, complete all as specified and directed.
Rendering 15 mm thick, on other than fair faces of brick work or concrete surfaces in cement mortar 1:6, finished surface even and fair, complete all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces of ceilings, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered surfaces with uniform layer of BIRLA wall care putty (1 mm thick) and applying two coats of weather proof paint coat over and including one coat of primer (in any colour or tint as approved) complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour over a coat of primer over 1mm thick uniform layer of wall care putty, complete all as specifed and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash, complete all as specifed and directed.
Preparation of old plastered surfaces of ceilings and applying one coats of white wash, complete all as specifed and directed.
Taking down eaves gutter rain water pipe (any size of pattern) including all fittings heads shoe, bend, tee, swan-necks, etc. incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
PVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
PVC (SWR) 110mm pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified and directed.
PVC (SWR) 75mm pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified and directed.
PVC (SWR) bends / shoe of any radius with acess door and 110mm bore, complete all as specified and directed.
PVC (SWR) bends / shoe of any radius with acess door and 75mm bore, complete all as specified and directed.
PVC (SWR) 75 mm dia, junction single, (single T), equal or unequal with oval access door fixed to PVC pipe joint with rubber solvent, complete all as specified and directed.
PVC (SWR) 110 mm dia, junction single, (single T), equal or unequal with oval access door fixed to PVC pipe joint with rubber solvent, complete all as specified and directed.
PVC (SWR) vent cowl, 110mm bore, complete all as specified and directed.
PVC (SWR) 75mm dia floor trap, plain with grating including jointing with solvent cement, fixed in repairs complete all as specified and as directed.
Stack clamps made out of 50 mm X 5 mm flat iron and iron stays, including bolts and nuts and securing ends of stays to wall or roof for fixing of 110 mm bore, complete all as specified and directed.
Stack clamps out of 50 mm by 5 mm flat iron and iron stays, including bolts and nuts and securing ends of stays to wall or roof for fixing of 75 mm pipe, complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed wate tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, complete all as specified and directed.
Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.), 15mm bore of pipe, complete all as specified and directed.
Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.), 20mm bore of pipe, complete all as specified and directed.
Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore fixed in repair, complete all as specified and directed.
Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, screwed both ends for iron pipe or for unions 15 mm bore, fixed in repair, complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, CI trap 100 mm Bore of pipe etc, fixed in repair, complete all as specified and directed.
PVC unbreakable (square) wall mounted shelf with 500 mm sides, fixed in repairs, complete all as specified and directed
Kitchen sinks with drainage board made of stainless steel 1 mm thick in kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm, in repair, complete all as specified and directed.
Vitreous China wash hand basin, with pedestal white flat back of size 580 mm x 400mm fixed on and fixing of cantilever brackets of mild steel angle 35 mm x 35 mm x 5 mm, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe (rigid quality) including fixing of tap, Mixture, waste fitting etc., fixed in repair, complete all as specified and directed. Note :- Mixture tap shall be measured & paid seperately as supply only under respective item.
Supply only 15 mm bore central hole basin mixer with 450mm braided connection pipe (without popup) complete all as specified and directed.
Chromium plated brass shower rose, 125mm dia, with shower arm ,swivel joints fixing to steel pipe or union of 15 mm dia pipe, fixed in repair, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions, 15mm bore, fixed in repair, complete all as specified and directed.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, ISI marked, double layered hoisted and fixed in position including connecting up pipes including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (minimum weight 210gms), fixed in repair, complete and including dismantling of old tank complete all as specified and directed.
Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore, fixed in repair, complete all as specified and directed.
PVC connection 15mm dia and 600mm long with 2 Nos brass fly nuts with washers, fixed in repair, complete all as specified and directed.
PVC waste pipe of 32 mm dia, flexible for wash hand basin, kitchin sink or urinals, complete all as specified and directed.
Low density polyethylene 40 mm bore pipes (LDPE) of pressure rating 6 kgf/cm2 and fittings, fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
Stainless steel plate rack (utensil rack) of size (600mmx750mm) and depth 300 mm made with 0.63 mm thick stainless steel sheet fixed with brass screw including necessary fittings, nut/bolts , washer etc., fixed in repair, complete all as specified and directed. Note: Sample of stainless steel plate rack shall be as approved by Accepting Officer.
Tubular towel rail of brass chromium plated, 20mm dia, D type, 60 cm long between flanges, fixed in repair, complete all as specified and directed.
Soap dish, stainless steel, standard size Soap dish, any type, fixed to plugs with chromium plated brass screws, fixed in repairs complete all as specified and directed.
Demolition of Plain cement concrete (PCC) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Water proofing treatment to sunken floor and sides as mentioned here-n-after:- (Step-I)Cleaning of RCC surface to remove existing treatment from sides and base slab by using sand blasting with compressed air. (Step-II) application of one coat to sides and base of sunken with glass fibre reinforced acrylic modified cementitious coating. (Step-III) 15 mm thick cement plaster on side and base slab of sunken part in cement mortar 1:3 mixed with appropriate integral water proofing compound as specified. (Step-IV) applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm on plastered surface of sunken sides & base. Note: All debris obtained from site will be thrown away out side Def Land by contractor at his own expense.
Cement concrete 1:5:10, type B-2( using 40 mm graded crushed stone aggregate) as in filling mass concrete (sunken part) of slab, finished even & rough to receive cement mortar screed bed complete all as specified and directed.
Cement concrete 1:2:4 type B-0 (12.50mm graded stone aggregate), 25mm thick, as in levelling course, complete all as specified and directed.
Stainless steel drapery rod cut to size and fixed in position including brackets, end knobs , 25 mm dia, fixed to wall, fixed in repair, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Taking down shutter of any description not exceeding 1 sq.m each including removing from site, complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Dismantling boarding any desccription fixed in any position with nails or any other means complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and directed.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed.
Pressed steel 25mm x 60mm frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete all as specified and directed.
Pressed steel 105mm x 60mm frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete all as specified and directed.
PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in bed block and filling in door frames complete all as specified and directed.
Provinding Factory made 100 % Solid WPC ( Wood polymer composite) Solid Enrouted Painted Flush door shutter of thickness 30 mm or required size comprising of virgin PVC resin of K value 57-60 (Suspension Grade), Calcium carbonate and natural fibres (Wood powders/ rice husk/wheat husk) and non toxic additives made from extrusion process WPC Foam sheet Single extruded (Inner) with density not less than 650 Kg/cbmhaving good screw holding capacity complete all as specified and directed
Factory made 30 mm thick wire gauzed i.e panel will be of wire gauze in lieu of wood grain printed PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S Solid tube and this tube shall be welded to M.S Tubes. The wire gauge shall be stretched to tighten firmly and door shutter (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top and bottom rail, lock rail & bottom rail on either side and as gap insert for top and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
Stainless steel handles, fabricated type, 150mm long, complete all as specified and directed.
Stainless steel, barrel tower bolts of extruded section and fixed, 200mm long, complete all as specified and directed.
Stainless steel, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet fixed, 250mm long, complete all as specified and directed.
Stainless steel hinge pin, 100mm long, complete all as specified and directed.
S&F 300mm, Mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete.
Floor door stopper of brass body and tounge anodised with hard drawn steel spring of cover plate length of 140 mm size, fixed in repair, complete all as specified and directed.
Salt-glazed stoneware gully traps, 150 x 150mm size, square or round mouthed, type 'P', setting and jointing in CM 1:1, complete all as specified and directed.
Mild Steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) as in ladder, cooler stand, chowkhat, complete all as speciifed and directed.
Celuka ply, 18mm thick, of single side prelam/ Rigidlam colour fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides, top and bottom and shelves inside the cabinets, complete all as specified and directed,
Celuka ply (PVC), 18mm thick, of plain white (Matt finish) fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides, top and bottom and shelves inside the cabinets, complete all as specified and directed,
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps 30mm (when open), complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortor superficial area not exceeding 150 Sq cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed.
Providing and fixing factory made uPVC (area note exceeding 2.0 Sqm each), white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm(+ - 0.2 mm). Window profile with hollow section with multi chamber.Frame (88 mm x 52 mm),sliding sash (42 mm x 67 mm ).Sliding mesh Sash (42 mm x 57 mm) Slide interlock (One vertical length in each shutters )(45.5 mmx 28 mm ),Glazing bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners,including railing of holes for fixing hardware and drainage of water etc. making arrangement for fising of hardware.EPDM gasket 1.2 + - 0.2mm thick galvanized steel frame (30mmx18 mm) 2 No.s ,sliding sash(30 mm x 18 mm),sliding mesh sash (26 mmx 10 mm) profile to be inserted in required profile ,frame will be fixed to wall with 8 mmx100 mm long fasteners.HardwareTouch lock of zinc alloyed (white powder coated ),steel roller system ,stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and required accessories complete all as specified and directed. (Note:The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.Net opening will be measured for payment purpose.)
Plain sheet glass, 4.8mm thick, ordinary quality and glazing with aluminium beading not exceeding 0.5 sq. m in each pane, complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, and similar work conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Frosted sheet glass, 4.8mm thick, ordinary quality and glazing with beading oil putty, area not exceeding 0.5 sqm in each pane, complete all as specified and directed.
Non skid coloured ceramic ENDURA tiles (1st quality) 10mm thick area of each tile, in floors, not exceeding 0.11 Sqm, set and jointed in neat cement slurry & pointed with coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) and 25 mm thick levelling course in PCC 1:2:4 type B-0 complete all as specified and directed.
Cement concrete 1:2:4 type B-0 (12.50mm graded stone aggregate), 25mm thick, as in levelling course, benching etc., and finished the surface even and rough to receive screed bed, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate), 75mm thick, as in levelling course, benching etc., and finished the surface even and rough to receive screed bed, complete all as specified and directed.
Magnetic catcher of size 20 mm X 50 mm suitable for cupboard shutter complete all as specified and directed.
Microconcreting of RCC columns, beams, slabs,chajjas etc., 25mm thick (total thickness) with approved design mix concrete (M-25) including the cost of necessary form work at edges and corners etc complete all as specified and directed.
Applying one coats of synthetic enamel paint on old steel surfaces of any description over 10 cm width or girth including preparation of steel surfaces complete all as specified and directed.
Cement concrete, 75 mm thick, type-D-2, 1:4:8 (40mm graded stone aggregate) as in sub base for floor finishes complete all as specified and directed
Machine pressed precast conctete interlocking paver block with grey cement & no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade laying over 25mm thick sand cushning complete all as specified and directed.
Plain cement concrete 1:2:4, type B-1 (Using 20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges coping etc incl necessary formwork complete all as specified and directed.
PVC low level flushing cistern 'white' with inlet, 10 litre capacity, with float valve including bracket with 32mm dia PVC flush pipe, fixed in repair, complete all as specified and directed.
Taking down carefully point wiring of any type and any description [light, fan, socket or power point] including fixture and fittings such as removal of material from site and keeping in safe custody for taking credit, making good disturbed surface to match the exisitng, complete all as specified and directed.
Taking down switches, distribution boards and old cut-outs etc., of any type and carefully along with the existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully sub-main wiring of any type and any numbers including earthwire and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
One light / fan / exhaust fan point, controlled by one one-way 5Amp switch
One 5 pin, 5 Amp socket outlet point on an independent board.
One 5 pin, 5 Amp socket outlet on the same board with other switches
One bell/buzzer point controlled by on bell push
One light point controlled by two two-way switches.
One 6 pin, 15 Amp socket outlet point on an independent board with cables of size 2.50Sqmm.
Switch piano, flush type, single pole, one way 5/6 Amp 230 volts, white or ivory, complete all as specified and directed.
Switch piano, flush type, single pole, two way 5/6 Amp 230 volts, white or ivory, complete all as specified and directed.
Socket outlet, 2 in 1, 5 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Switch piano, flush type, single pole, one way 15/16 Amp 230 volts, white or ivory, complete all as specified and directed.
Socket outlet, 2 in 1, 6 pin, 15/16 Amps 230 Volts, flush type, complete all as specified and directed.
Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
Switches, bell push, flush type, 5 amp, complete all as specified and directed.
Electric bell ding dong type AC 230 Volt 50 hz single pole, complete all as specified and directed.
Ceiling fan regulator flush type, electronic, rotary stepped type, AC 230 V, suitable for any type of ceiling fan, complete all as specified and directed.
Sheet metal enclosure for MCB DBs SPN, 8 way, double door, 240 V with 200 Amps rated bus bar, complete with incoming/ outgoing connection through proper size of lugs and cable glands, complete all as specified and directed
MCB SPN 6-32 Amp, 240 volts 10 KA, 'C series' complete all as specified and directed.
MCB SP 6-32 amps 230 Volts, 10 KA 'C series' complete all as specified and directed.
LED mirror light fitting 1 x 10 watt, LED 6000 K decorative , indirect up down LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire two core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly in repair, complete all as specified and directed.
LED bulk head light fittings 1x10 watt having 600 Lumen enclosed in polycarbonate body, weather proof with co-extruded poly carbonate body, envoirement friendly, energy efficient pre-wired and making necessary electric connection from ceiling rose with flexible copper wire or fixed to wall firmly, fixed in repairs, complete all as specified & directed.
LED wall mounted tube light fittings 1x18 watt four feet long decorative box type [Ultra slim] linear LED [6000K] with co-extruded polycorbonate body, envoirement friendly, energy efficient prewired and making conection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2mtr, fixed on wall firmly, fixed in repair, complete all as specified and directed.
Decorative wall light fixture made up of polycorbonate suitable for 15W TU retrofit CFL (B-22 base) polycorbonate body, weather proof, LED light fitting fixture with co extruded polycarbonate body, environmental friendly, energy efficient complete with all accessories, prewired and making connection with and including three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp complete all as specified and directed.
Road lighting luminaire, 36 Watt, with unique peanut optics to ensure uniform distribution, higher spacing between poles and maintenance free system for city roads and Streets, 50% Energy Savings, IP66 Protection PC and FG Cover, High Impact Resistance complete including LED Lamps and all accessories including bracket made out of 25mm bore GI pipe (light grade), 1.20 m long made to shape and fixed to existing pole or building by means of 2 Nos mild steel flat iron 40x6mm clamps with suitable size bolt, nuts & washers and connecting with three core flexible copper wire of size 23/0.0076 from ceiling rose to existing junction box, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Taking down carefully ceiling fan/exhaust fan by disconnecting all electrical connection and refixing the same including electric connection wire 3 core 23/0.0076 copper conductor including one coat of synthetic enamel paint and marking MES No. with paint after necessary repair work complete all as specified and directed.
Taking down carefully geyser fan by disconnecting all electrical connection and refixing the same including electric connection wire 3 core 23/0.0076 copper conductor including one coat of synthetic enamel paint and marking MES No. with paint after necessary repair work complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 to 32 Amps, fixed in repair, complete all as specified and directed.
creative construction co.
MS BHAVANA ENTERPRISES
Channa Brothers and Co.
Shivagya Engineering
KRISHNA BAHADUR
Hi-Tech Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .