Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being lowest Tenderer as L1. | |
| 2 | L2₹40.3 L+₹3.4 L (9.35%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance Rejected Not being lowest Tenderer. | |
| 3 | L3₹41.9 L+₹5.1 L (13.8%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected Not being lowest Tenderer. |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
12 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jorhat
HQ CWE (AF) Jorhat, Rowriah, Assam - 785005
ADDN/ ALTN TO EXISTING ELECTRIFICATION AND ALLIED WORK AT 764 ASC BN UNDER GE (AF) MOHANBARI
2023_MES_580120_2
83976/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Dinjan under GE (AF) Mohanbari
Please refer tender documents and NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) Mohanbari
₹49,800
Yes
20 Mar 2024
9 May 2023
19 Jun 2023
9 May 2023
12 Jun 2023
29 May 2023
Amount
Supply, install, testing and commissioning of outdoor type transformer step down, copper wounded having primary side for HT Three Phase 11 KV & secondary for 3 phase 433 Volts, 4 wire, 50 Hz of capacity 400 KVA as per IS-1180 Part-I (or as per latest IS amendment), Level-II with and including the following specification:- (i) No load voltage ratio-11KV/ 0.433 KV, (ii) Nos of phase-three (iii) Type of cooling- ONAN, (iv) Frequency-50 Hz (v) Vector group-DYN 11 (vi) Two earthing terminals for body earthing and additional for neutral (vii) Oil level gauge indicating oil level with minimum and maximum indication (viii) Lifting lugs rollers and MS terminal Box on both HT and LT side (ix) Rating and terminal marking plates (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve preferably steel with plug (xii) Thermometer pocket with temprature indicatior (xiii) Oil filling hole with cover (transformer wih conservator) (xiv) Connection-Delta/ Star (xv) Temperature rise in oil-40 deg celcius (xvi) Temperature rise in windings- 45 deg celcius (xvii) Material winding-Copper wound (xviii) High voltage/ low voltage with cable termination box (xix) Service-Outoor type (xx) Neutral- Internally conneted with earthing lead and bush (xxi) Off load tap changar (+5% to -10% in steps of 2.5% with 7 position) (xxii) First filling of new dehydrated transformer oil upto recommended level complete with all fittings/fixtures & accessories. Note:- Plinth foundation for the transformer as recommended by manufacture or as directed by engr-in-charge shall deemed to be include in item quoted rate.
S&F gang operated air break switch triple pole, mechanically manual operated, mounted on 9 Nos insulator and steel frame, with operating mechanism worked from ground level, for current rating 200 Amps, 11000volts complete all as specified and directed.
S&F drop out fuse unit expulsion type for outdoor air brake gang operated switches, single pole, mounted and including insulator for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line taps and suitable for current carryout capacity 25 Amps complete all as specified and directed.
M&L for steel tubular swaged poles, type seamless, 410-SP-55 (11 Metre long) for making 2 pole/ 4 pole structure including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified. Note:- (a) Earthwork/ PCC shall be measured and paid under appropriate items in Schedule.
Supply, laying, testing & commissioning of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11 KV grade of size 3 core, 95 Sqmm complete all as specified and directed.
Supply & laying unreinforced precast concrete cable cover class HV type 2, flat shape, dimension 450 mm X 180 mm X 40 mm complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size 25x20cm for HT 11KV complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 6mm dia as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
S&F lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, 11000 volts complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and directed.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable, outdoor end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 95 sqmm, 3 core XLPE armoured aluminium conductor cable and testing complete all as specified and directed.
M & L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and as directed.
M&L galvanised stay strand 7/3.15 complete allas specified and directed
M&L for loop insulator large size with overall dimensions 90mmx140mm, clearance of hole 25.5mm complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete all as specified and directed.
M&L for hardcore of broken bricks n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for cement concrete type B- 2, 1:2:4 (40mm graded aggregate) 150 mm thick as in foundation, filling & mass concrete all as specified and directed.
M&L for rendering 10mm thick cement (1:6) plaster on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for preparing surfaces of newly plastered surfaces of walls and applying 3 coats of white washing complete all as specified and directed.
M&L for cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for post holes complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1, (using 20mm graded stone aggregate) for coping of poles and stay including necessary form work complete all as specified and as directed.
M&L for excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil complete all as specified and directed.
M&L for rolled mild steel in joints, channels, angle or Tee sections fixed independly without connecting plates etc complete all as specified and directed.
M&L for preparation of new steel surface surfaces of any description, otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint (ordinery tint) over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for chain link fencing 3.8 mm dia galvanized PVC coating wire (50x50) mm mesh made upto matress lapped wire and laid on postion/fixed on poles complete all as specified and directed.
M&L for chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
S&F MS screw bolts (machine made) 11 to 15mm dia exceeding 5cm & n exc 10cm long hexagonal or square head at one end and screwed other end to be fixed with one washer and one hexagonal nut, the other end to be embedded in RCC fencing post while casting complete all as specified and directed.
S&F MS flat iron hold fast for securing wire mesh and similar small articles, cut to length, bent to shape, drilled hole including all necessary drilling, bolting and fixed with screw etc. complete all as specified and directed.
M&L mild steel round bars 6 to 8 mm dia cut into length bend to shape required including cranking bending spirally for hooping for columm, hooking ends and for strirrups spacers and binders binding with & including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
M&L for framed work as in door or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other convering door, etc. with Fe-290 to be prepared of hanging or sliding with an including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other convering, running rails and guides) and hanging also fastening and fixing including ornamental and intricate design complete all as specified and directed.
M&L for disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
M&L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
Supply, laying, testing & connecting cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & connecting cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & connecting cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting (aluminium paint) and writing pole serial number using paint in white colour on black backgound complete all as specified and directed. (Note : Excavation and Earth work shall be measured and apid separately)
S&F PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal two Nos in span complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as required or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade complete all as specified and directed.
M&L for shackle type porcelain insulator, vitreous, white, brown or green including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and directed.
Excavation in trenches for laying the cable/ pipe/ pole not exc 1.5 m wide and 1.5 m depth in soft loose soil complete all as specified and directed.
Excavation in trenches for laying the cable/ pipe/ pole exceeding 1.5 m in depth and n. exc 1.5 m wide in soft loose soil complete all as specified and directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for fine sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified & directed by Engr-in-charge. Note: (i) Punned thickness of sand shall be measured & paid.
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m complete all as specified and directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 80 mm bore complete all as specified and directed.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Supply and fixing GI protection pipe of 80 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified. Note:- Earth work shall be measured and paid separately.
M/s HALDER ENTERPRISE
STANDARD ELECTRIC WINDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .