| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC NO 586 S2 PRAGATHI FLATS ARUL NAGAR IRUMBULIYUR EAST TAMBARAM CHENNAI KANCHIPURAM TAMIL NADU 600059 | CHENGALPATTU | TAMIL NADU | 600059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.6 L+₹1.4 L (22.0%)Rejected-Finance NO 33 JEENIS ROAD SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-Finance L2 |
Tender Value
₹5.9 L
Closing Date
10 Dec 2021, 6:00 pmClosed
S.M (E E)
S.M (E E), RHQ/SR, AAI
PROVISION OF FIRE ALARM SYSTEM AT PUDUCHERRY AIRPORT
2021_AAI_96631_1
AAI/RHQ/SR/SM(E-E)/Pdy/FAS
Open Tender
Electrical Works
Item Rate
60 days
Puducherry Airport
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,180
Exempted
11 Dec 2023
2 Dec 2021
13 Dec 2021
3 Dec 2021
10 Dec 2021
3 Dec 2021
3 Dec 2021 - 7 Dec 2021
Supply, installation, Testing & commissioning of UL/EN Listed 16 bit intelligent Addressable Fire Alarm Panel with 2 loops (each loop accessing at least 120 detectors ) including battery backup. The panel shal be microprocessor based with its own micro controller, memory, communication module and fire device loop interface cards for intelligent initiating and indicating devices and should also be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all control Switches when ever any Alarm is triggered. The Panel shall have Keypad operation, LCD unit to indicate Fire/Fault Signal of individual unit, etc complete in all respects. Battery shall be 54 Ah SMF type. The panel shall also have logic hardware and software built into it for initiating specific AHU tripping, time delay operation of hooter. Panel shall be networked to Main Panel. a)Programming software for the system b)automatic sytem test activates c)detector sensitivity adjustments d)alarm verification e)Alpha/numerical display f)provision to connect to PCs and external printers g)Support modbus/bacnet protocol (Make: As per list of approved makes)
Supply, installation, Testing & commissioning of Conventional Fire Alarm control Panel having minimum of 2 Zones suitable for connecting sensors manual call points, hooters and response indicators , operation with 220 Volts, 50 HZ Power supply , LCD display to indicate fire and normal operation & power supply status, Push button for accept and reset , sealed lead acid batteries with 2 Nos 12V, 7AH battery backup on alarm mode & normal operation with battery charger etc., shall be complete etc as required. (Make: As per list of approved makes)
Supply, Installation, Testing & Commissioning of UL/EN Listed Repeater panel for addressable Fire Alarm system with Piezosounder, LCD alpha numeric character display with accept/rest buttons for alarm address of any sensor/field address with room number etc as required. (Make: As per list of approved makes)
Supply, Installation, Testing & Commissioning of Auto Dialer for Fire Alarm system suitable to work with existing landline line telephone connections etc as required.
Supply & fixing of Photoelectric, Multi sensor smoke detectors along with mounting base with unique optical sensing chamber, visible LED's fully coated circuit boards with RF/transient protection, complete with all accessories including connections etc. as required. (Make: As per list of approved makes)
Supply, installation, Testing & commissioning of UL/EN Listed Analogue Addressable type Optical Smoke Detector complete with all accessories like base, base box, etc., to be installed under/above false ceilling, roof and concealed space, etc., interconnecting to loop cable complete as required. (Make: As per list of approved makes)
Supply, installation, testing and commissioning of UL/EN Listed intelligent Addressable type Optical Smoke cum heat Detector (3D) complete with all accessories like base, base box, etc to be installed under/above false ceiling, roof and concealed space etc. interconnecting to loop cable complete as required. (Make: As per list of approved makes)
Supply, installation, testing and commissioning of UL/EN Listed Analogue Addressable type heat Detector (fixed cum rate of rise type) with range 60 Degree complete with all accessories like base, base box, etc to be installed under/above false ceiling, roof and concealed space etc. interconnecting to loop cable complete as required. (Make: As per list of approved makes)
Supply, installation, testing and commissioning of response Indicators outside the rooms for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete as required. (Make: As per list of approved makes)
Supply, installation, testing and commissioning of UL/EN Listed Addressable type Manual Call Point (break glass / pull station type) complete with input Module, Push Botton, enclosed in box with provision for cable or conduit coupling. (Make: As per list of approved makes)
Providing , installing, testing and commissioning of UL /EN Listed Hooter cum Strobe complete with Base plate, box etc., as required. (Make: As per list of approved makes)
Supply Installation, testing and commissioing of UL/EN Listed Infra Red Beam detector reflective type for up to 100m span and 15m width, complete with Transmitter, receiver, brackets and Input Module complete with four square reflector, all fixing accesssories like base, base box, etc. to be installed on wall, connected space, etc. interconnecting to to loop cable complete as required and PVC flexible conduit. (Make: As per list of approved makes)
Supply Installation, testing and commissioing of addressable and automatic commandable control modules etc as required.
Supply Installation, testing and commissioning of addressable loop Isolators etc as required.
Supply and laying of MS steel conduits ISI Marked red painted with all fittings and saddles for drawing detector control cables on surface /recess/above false ceiling/concealed space/wall concealed, etc of following sizes: 20 mm (Make: As per list of approved makes)
Supply and laying of following size PVC insulated FRLS 2Cx1.5sq.mm copper conductor cable through conduits/surface/recess/above false ceiling/concealed space/wall concealed, etc. for control cabling for Fire detection & alarm devices and interconnecting etc as required. (Make: As per list of approved makes)
Ponmani International (India) Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .