| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹3.9 L+₹1.2 L (44.3%)Accepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L2 | Accepted-Finance ok | |
| 3 | L3₹5.0 L+₹2.3 L (84.5%)Accepted-Finance | L3 | Accepted-Finance ok | |
| 4 | L4₹5.0 L+₹2.3 L (86.8%)Accepted-Finance G 11 B 2 SARINE SONIA COMPLEX VIKAS PURI NEW DELHI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | L4 | Accepted-Finance ok | |
| 5 | L5₹5.1 L+₹2.4 L (90.6%)Accepted-Finance | L5 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹10,300
Closing Date
28 Jan 2022, 11:15 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (EnM) M-8
C-2A Block Janakpuri BPS New Delhi-110058.
Strenghtening of Electric System at Tilak Nagar BPS, Tilak Nagar Constituency.
2022_DJB_215227_16
e-NIT No.03 / (EnM) M-8/ 2021-22
Open Tender
Miscellaneous Works
Works
30 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Document
3 documents required · 3 mandatory
₹500
Yes
DJB Account No. 50448339804
₹10,300
Yes
26 Feb 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
120 days
Supply & Installation of LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1200MM X 1000MM X 400MM. Having following components make. MCCB 415V, TP 3phase 50Hz, 250Amp with handle & Spreader: - 1 No. Make L&T/Siemens MCCB 415V, TP 3phase 50Hz, 160Amp with handle & Spreader:- 2 No. Make L&T MCB Single pole 6Amp:- 7 Nos. Make L&T/Havells MCB Triple pole 32Amp:- 2 Nos. Make L&T/Havells Power capacitors 415V unit of 25 Kvar:- 2 Nos. Make: Epcos Over load relay (66-110) amp:- 2 Nos. Make: L&T/siemens Over load relay (6-10)Amp:- 2 No. Make: L&T/siemens Digital Amp. Meter: - 4 Nos. Make AE/L&T Digital Volt Meter0-500V:- 1 No. Make AE/L&T Motor protection Relay: - 2 Nos. Make: L&T/Siemens Power contactor 220V 3phase 160 Amp:- 4 Nos. Make L&T / siemens Power contactor 220V 3phase 100 Amp:- 2 Nos. Make L&T / siemens Power contactor 220V 3phase 25 Amp:- 1 No. Make L&T / siemens Star delta timer on delay: - 2 No. Make: L&T/Siemens Indicating lights LED type RYB & On/OFF: - 7 Nos. Make : L&T / Havells Current Transformer200/5, 50/5:- 9 Nos. Make AE / Advance Current Transformer250/5:- 3 Nos. Make AE / Advance On load change over switch 200Anp. Open execution type: - 1 No. Make: L&T Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hardware complete in all respect. Loading, unloading by crane or heavy labor and cartage up to site. Dismantling of old panel structure including removing of cable etc. from site, cleaning & dressing the surface for Installation of the panel at site on base frame, laying of cable, termination of cable both incoming & out going side. Testing & commissioning of panel & allied accessories as per required parameters with relevant IS .testing of the panel prior to switching on as follow :- (i) Continuity and earth testing. (ii) Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth.
PVC insulated (heavy duty) single-core un armoured copper conductor cables for working voltage up-to and including 1100 volts of 35 cross section. Make: Grandlay/Gloster/Havells
Providing of 45 watt LED, street light fitting pressure die cast AL. housing with heat resistant toughened glass & IP 65 Protection, complete with all accessories. Make: Havells/Bajaj/ Crompton.
Providing of 72 watt LED, street light fitting pressure die cast AL. housing with heat resistant toughened glass & IP 65 Protection, complete with all accessories. Make: Havells/Bajaj/ Crompton.
Wiring for circuit /sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor. Single core cable in surface / recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. (DSR 1.14.3)
Premier Engineering Company
Swarn Engineers
Prime India Associates
Gupta Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .