Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹85.9 L Quoted ₹81.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹84.2 LRejected-AOC | ₹84.2 L | L2 | Rejected-AOC NOT L1 |
| 3 | L3₹85.6 LRejected-AOC | ₹85.6 L | L3 | Rejected-AOC NOT L1 |
| 4 | L4₹86.3 LRejected-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹86.3 L | L4 | Rejected-AOC NOT L1 |
| 5 | L5₹88.2 LRejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹88.2 L | L5 | Rejected-AOC NOT L1 |
| Sl No | Description | Qty | Unit | sapana enterprises L6 | BRITE INDUSTRIES L2 | Shree Ayyappa Engineering L1 | pk Enterprises L4 | shubham construction L3 | shakti engineering and electrical works L5 |
|---|---|---|---|---|---|---|---|---|---|
| 0.00SCH 'A' PART-I (MAINTENANCE OF AC PLANTS) | |||||||||
| 1.00Material and labour for dismantling electric motor of any make, 3 phase 415V of following capacity, opening the motor for rewinding using super enameled copper wire of suitable gauge to match with the existing winding as per manufacturer design including varnishing & drying and re-assembling the motor, connecting with proper alignment and testing complete including transporting to workshop for rewinding complete all as directed. | |||||||||
| 1.01 | (a) 10 HP | 2 | Each Job | 6,700 ₹13,400 | 10,000 ₹20,000 | 6,000 ₹12,000 | 6,700 ₹13,400 | 7,700 ₹15,400 | 6,700 ₹13,400 |
| 1.02 | (b) 7.5 HP | 2 | Each Job | 5,600 ₹11,200 | 10,000 ₹20,000 | 5,000 ₹10,000 | 5,600 ₹11,200 | 9,800 ₹19,600 | 5,900 ₹11,800 |
| 1.03 | (c) 5 HP | 2 | Each Job | 4,000 ₹8,000 | 1,000 ₹2,000 | 3,000 ₹6,000 | 9,000 ₹18,000 | 4,000 ₹8,000 | 4,500 ₹9,000 |
| 1.04 | (d) 1 to 3 HP | 2 | Each Job | 3,500 ₹7,000 | 5,000 ₹10,000 | 3,000 ₹6,000 | 1,000 ₹2,000 | 3,500 ₹7,000 | 4,500 ₹9,000 |
| 2.00Material and labour for Servicing of water pump split casing type set by removing & dismantling pump and connected pipes & electric connections etc and replacing of unserviceable parts with new gland packing set Gun metal bushes, bearing, water seal packing complete cleaning of impeller greasing etc reassembling and refixing in original position complete with packing and necessary nut & belt etc including testing for smooth functioning etc of following capacity all as specified and directed. | |||||||||
| 2.01 | (a) 7.5 hp | 4 | Each Job | 7,900 ₹31,600 | 7,750 ₹31,000 | 7,720 ₹30,880 | 7,900 ₹31,600 | 9,000 ₹36,000 | 7,787 ₹31,148 |
| 2.02 | (b ) 5 hp | 4 | Each Job | 3,200 ₹12,800 | 3,120 ₹12,480 | 3,120 ₹12,480 | 2,100 ₹8,400 | 3,500 ₹14,000 | 3,155 ₹12,620 |
| 3.00 | (a) Supply and fix in repairs scroll compressor 30/39/26 TR from the unit after disconnecting electrical wiring & piping connection nuts & bolts etc supply & install of new scroll compressor 30/39/26 TR capacity and connecting pipe line for existing piping brazing & electric connection etc complete all as specified and directed.IGLOO,DBM,PMS | 5 | Each Job | 98,990 ₹4.9 L | 98,650 ₹4.9 L | 98,600 ₹4.9 L | 98,695 ₹4.9 L | 98,699 ₹4.9 L | 98,699 ₹4.9 L |
Tender Value
₹84 L
EMD Value
₹1.5 L
Closing Date
8 Jan 2026, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
COMPREHENSIVE MAINTENANCE OF AC PLANT AT HTL,WHJBC ,PMS ,IGLOO,DBM, MTP AC PLANTS, ACS INCLUDING FIRE ALARM SYSTEM CERTAIN BUILDING OF NAD, VAJRAKOSH UNDER GE (SB) KARWAR
2025_MES_744040_1
86021/E8
Open Tender
Civil Works
KARWAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE(SB) KARWAR
₹1.5 L
Yes
24 Feb 2026
11 Dec 2025
10 Jan 2026
11 Dec 2025
8 Jan 2026
1 Jan 2026
(d) 1 to 3 HP
(a) Supply and fix in repairs scroll compressor 30/39/26 TR from the unit after disconnecting electrical wiring & piping connection nuts & bolts etc supply & install of new scroll compressor 30/39/26 TR capacity and connecting pipe line for existing piping brazing & electric connection etc complete all as specified and directed.IGLOO,DBM,PMS
(a) 3x26 TR at IGLOO
(b) 3x30 TR at PMS
(c) 2x30 TR at WHJBC
(d) 3x39 TR at DBM
Supply & charge refrigerant (R - 134A) gas as per requirement
(a) Water Flow Switch complete all as directed .
Topping up / Replacement of compressor oil with new compressor oil complete all as directed
(c) Single phase preventor for compressor /Motor for SM 101 GIC or eqv in L&T/Minilec/ABB
(d) Strip type 3 KW Heaters
(e) Strip type 2.0 KW Heaters
(f) Pressure gauge 0-300 PSI .
(g) Pressure gauge 0-150 PSI
(h) Crank case heater 250 W suitable for 39/30/26 TR CHW plant
(j) Filter drier core for 39/30/26 TR Central AC Plant
(k) LP/HP cut out switch for 39/30/26 TR Central AC Plant
(b) Moisture liquid indicators complete all as directed.
(m) Float Valve for 25 mm
(n) Cooling tower fins of size 4'x6'
(l ) V belt for Cooling tower .
(a) 101 USGPM at IGLOO
(b) 141 USGPM at DBM
(c) 75 USGPM at PMS/WHJBC
Note: (a)Defective parts of plants will be replaced and measured under respective item of this schedule. (b) Fins, bearing , float valve required for replacement will be measured under respective item of this schedule.
Supply and fixing in repair Nitrile insulation layers of size 25 mm thickness sticking on the chiller surface by using approved adhesive and ceiling joint by weather proof tape after removing unserviceable nitrile insulation from the chiller & cleaning complete all as directed by Engineer-in-charge.
Supply and fixing in repair pre filters 10 Micron as per existing make complete all as specified and directed.
(a) Supply and fix in repairs MS pipe heavy grade 80 mm dia including removing of unserviceable MS pipe medium grade of 80 mm dia complete all as specified and directed
(b) Supply and fix in repairs MS pipe heavy grade 100 mm dia including removing of unserviceable MS pipe medium grade of 100 mm dia complete all as specified and directed
(c) Supply and fix in repairs MS pipe heavy grade 40 mm dia including removing of unserviceable MS pipe medium grade of 40 mm dia complete all as specified and directed
(d) Supply and fix in repairs MS pipe heavy grade 50 mm dia including removing of unserviceable MS pipe medium grade of 50 mm dia complete all as specified and directed
(e) Supply and fix in repairs butter fly valve 50 mm dia including removing of unserviceable butter fly valve of size 40/50 mm dia complete all as specified and directed.
(f) Supply and fix in repairs butter fly valve 100 mm dia including removing of unserviceable butter fly valve of size 100 mm dia complete all as specified and directed.
(g) Supply and fix in repairs butter fly valve 65 mm dia including removing of unserviceable butter fly valve of size 65 mm dia complete all as specified and directed.
(h) Supply and fix in repairs MS pipe heavy grade 65 mm dia including removing of unserviceable MS pipe medium grade of 65 mm dia complete all as specified and directed
(a) ditto but for 7.5 TR
Material and labour for periodical maintenance of duct AC of 5 Ton capacity including cleaning of overhead ceiling supported indoor unit complete, duct system, blower, outdoor unit, wiring system, cool air vent, checking function of fire damper, clearing including, oiling / greasing of movable parts of indoor unit such as motor bearing etc, fresh electrical connections, checking insulation of wiring etc complete, all as specified and directed.
All as per item No 19 above but 7.5 Ton duct AC.
All as per item No 19 above but for 3 Ton Tower AC
(a) Refrigeration circuit of floor mounted Tower AC of capacity 3 Ton .
(b) Refrigeration circuit of Duct AC of capacity 5 Ton .
(c) 3 Nos of Refrigeration circuit of 2.5 Ton each for Duct AC of capacity 7.5 Ton. Note :- Qty of gas will be measured and paid separately.
(a) 3.0 TR Capacity of floor mounted AC /tower AC
(b) 5 TR capacity of duct AC
(c) 7.5 TR capacity of duct AC
Material and labour for taking down unserviceable fan blower motor of 1/2 HP capacity from outdoor unit of duct / floor mounted AC and rewinding motor, varnishing, drying etc, replacement of bush, assembly etc suitable for Blue Star make and fixing it back complete all as specified and directed.
Supply and fix in repairs 12 way wiring connector terminal for duct AC / tower AC complete all as specified.
Supply and fix in repairs fan blade assembly for outdoor unit suitable for Blue Star make following capacities.
Supply and fix in repairs capacitor of 10-36 mfd, plastic body complete assl as specified and directed.
Supply and fix in repairs single phase preventer cum controller for operation of floor mounted AC of 3 Ton capacity.
Supply and fixing in repair MCB TPN 32 to 40 Amps complete all as specified and directed.
Supply and fix in repair Manual Call Point (MCP) complete all as specified and directed. Make Notifier Cat No. F/MCP/Glass
Supply and fix in repair Addresable thermal detector with flash scan complete all as specified and directed. Make Notifier Cat No. FST/851R+B/501UL
Supply & Laying in repairs of 2 Core 1.5 Sq mm Copper armoured Cable for smoke detectors and MCB etc complete all as specified and directed by Engineer-in-charge.
Fire Alarm Sounders / Sirens Electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 3500 Mtrs range
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_833124.xls
BOQ • 0.41 MB
86021Tender.pdf
Tender Documents • 0.74 MB
Download all tender documents and submit your bid