GE JUTOGH
GE JUTOGH, JUTOGH CANTT SHIMLA (HP) - 171008
PROVN OF INSTLN OF 08 X SENSOR BASED/ HERMETICALLY SEALED DOORS IN ICU, OT AND CSSD FOR MAIN HOSPITAL BLDG, PROVN OF ELEVATED SANTRY POST WITH TOILET FACILITIES AT MAIN GATE OF 102 INF BN (TA) PUNJAB AND PROVN OF PRE-ENGINEERED SHEETS OVERHEAD COVER
2021_MES_460572_2
GE/JUT-25 OF 2021-22
Open Tender
Civil Works
Item Rate
120 days
SANJAULI
CLASS E CATEGORY a (i)
6 documents required · 6 mandatory
₹500
GE JUTOGH
₹46,000
Yes
23 Sept 2021
16 Aug 2021
9 Sept 2021
16 Aug 2021
7 Sept 2021
24 Aug 2021
Amount
Supply & Installation of fully Automatic Sliding door operator (Total size 2400 x 2450 mm and sensor door opening size 1150 mm wide x 2100 mm height of each sensor door) with ST flex profile for door for 12mm Flat Edge Clear toughened Glass Moving Doors and side fixed panels, complete with future European standards and produced according to the guidelines for power-operated windows, doors and gates BGR 232, the UVV and the VDE regulations. TÜV design tested. Fulfils the DIN V18650 (prEN 12650). Automatic Sliding Door Operator should have mounting backplate for easy installation and a flexible track profile for improved noise & vibration dampening and easy maintenance. Microprocessor-controlled control unit. Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force. Class of protection IP 20. Automatic door Operator should be with Anti-Jump fitting with clear passage of minimum width 1150 mm SD (Two shutters of equal width) and maximum clear height of 2100 mm. Door Panel weight grater than 2x90 kg. With the following accessories Function programs: Program Modes: - Off, Automatic, Permanent open, Exit only, Partial open.
Supply & Installation of fully Automatic Sliding door operator (Total size 3000 x 2450 mm and sensor door opening size 1450 mm wide x 2100 mm height of each sensor door) with ST flex profile for door for 12mm Flat Edge Clear toughened Glass Moving Doors and side fixed panels, complete with future European standards and produced according to the guidelines for power-operated windows, doors and gates BGR 232, the UVV and the VDE regulations. TÜV design tested. Fulfils the DIN V18650 (prEN 12650). Automatic Sliding Door Operator should have mounting backplate for easy installation and a flexible track profile for improved noise & vibration dampening and easy maintenance. Microprocessor-controlled control unit. Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force. Class of protection IP 20. Automatic door Operator should be with Anti-Jump fitting with clear passage of minimum width 1450 mm SD (Two shutters of equal width) and maximum clear height of 2100 mm. Door Panel weight grater than 2x90 kg. With the following accessories Function programs: Program Modes: - Off, Automatic, Permanent open, Exit only, Partial open.
Taking down chowkhats or frame (without taking off shutters from frame) exc 1.50 Sqm but nexc 4.0 Sqm and removing to store, complete all as specified.
M&L for 10mm thick rendering on fair faces of brick or concrete surface of wall in cement mortar 1:6 and finish the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new wall surfaces and applying one coat of priming paint plaster and two coats of plastic emulsion paint, complete all as specified and directed.
M&L for half brick work with sub class 'B' brick in CM 1:4, straight or curved on plan to any radius, complete all as specified and directed.
Excavating over areas, n exc1.5 m deep and getting out hard/dense soil complete all as specified and directed.
All as per Srl Item no 7.00 above but for each additional 1.5m or part or part thereof in depth beyond the first 1.5m
Excavation in trenches, n. exc. 1.5 m wide and n.exc 1.5 m in depth, for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc.n. exc. 10 sq m on plan and n. exc. 1.5 m in depth and getting out soft/disintregated rock complete all as specified and directed.
M & L for PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:3, complete all as specified and directed.
M&L for brick work with subclass 'B' in one brick thick honey comb walling built in CM (1:6) etc complete all as specified and directed.
M&L for broken brick bats loose filling in soakage pits/ filter beds etc complete all as specified and directed
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking , bending, hooking end and binding with and including mild steel wire not less than 0.9 mm dia and securing with clips complete all as specified and directed.
M&L for RCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including form work compete all as specified and directed.
Formwork to sides and soffits of flat rough finished rough surface concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for concrete bed to drain pipes in PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate, including packing under and completely surrounding the pipes after they are laid and tested, bore or pipe 110mm complete all as specified and directed.
Returning filling in including spreading levelling watering well ramming in layers not exc 25cm thick complete all as specified and as directed.
Removing of excavated materials (soil) exc 50m but n. exc 250m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified.
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry surface in cement mortar (1:4) finished even & smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping, block for hold fast block or similar work and finished the surface with existing and including form work complete all as specified and directed .
S & F PVC (SWR) Pipes single socketed in any length with rubber ring joints , fixed to wall 110 mm bore compete all as specified and directed.
S & F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors compete all as specified and directed.
S & F PVC SWR Bends in any radius 75 mm bore with access door compete all as specified and directed.
S&F PVC (SWR) Vent cowl 110 mm bore compete all as specified and directed.
S&F 110mm dia PVC (SWR), junction single, (Single T) equal or unequal compete all as specified and directed.
S & F PVC SWR Bends in any radius 110 mm bore with access door compete all as specified and directed.
Formwork to sides of concrete foundations , footings, bases of columns, raft & raft beams, sides & soffits (if any) of foundation and plinth beams and similar work vertical or batter for fair finish surface complete all as specified and directed.
Form work to sides & soffits of floor or roof beam beam haunchins girders bressumers lintels cantilevers shelves including over hang supports etc. for rough finish surface complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns & stanchions incl fair finishes of surfaces complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking , bending, hooking end and binding with and including mild steel wire not less than 0.9 mm dia and securing with clips complete all as specified and directed.
M&L RCC (nominal Mix) 1:2:4, type B-1, using 20mm graded crushed stone agreegate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L RCC (nominal Mix) 1:2:4, type B-1, using 20mm graded crushed stone agreegate as in columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L RCC (nominal Mix) 1:2:4, type B-1, using 20mm graded crushed stone agreegate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L RCC (nominal Mix) 1:2:4, type B-1, using 20mm graded crushed stone agreegate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as per specified and directed
M&L for PCC 1:2:4, type B-1, using 20 mm graded crushed stone aggregated as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throttling, as directing including necessary form work compete all as specified and directed.
S&F framed work such as grills, gratings, etc.,with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder, framed baluster, walk ways; railing, framework of watertanks staging and similar work conforming to Fe-290. Gde-E-165 compete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick on fair surfaces of brickwork or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement at any height complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry surface in cement mortar (1:4) finished even & smooth without using extra cement with water proofing compound complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 on concrete surface of ceiling etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for moorum/red bajari filling in floors or pavings, laid in layers not exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for Hard core of gauge n exc 63mm thick of broken stone or boulder spread and levelled in layers n.exc 15cm thick, watering, ramming to true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in plinth protection, hard sanding and path finished concrete surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x7 mm or 450x300x6 to 7 mm thick on vertical surface such as skirting/dado set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match the existing surface incl 10mm thick rendering in cement mortar 1:3 etc complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x47mm made out of 5mm thick plain coloured PVC sheet reinforced with M.S. Square tube, compete all as specified and directed.
S&F Factory made panel PVC door shutter 30 mm thick (style) consisting of frame made out of M S tubes for top & bottom rails M S frame shall be covered with heat moulded plain colour PVC ‘c’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour pick sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, Paneling of colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable pick sheet beading and jointed together with solvent cement compete all as specified and directed.
S&F Butt hinges 75 mm size medium weight cold rolled mild steel compete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size compete all as specified and directed.
S&F 200 mm aluminium anodised barrel tower bolt of extruded section and fixed, compete all as specified and directed.
S&F factory made steel ventilator with top hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars complete all as specified and directed.
S&F sheet glass 3 mm thick Figured glass, pin head type and glazing with oil putty or wooden bead in squares n exc 0.5 sq. m in each, compete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical type with closed top) of 500 litres capacity, ISI marked, triple layered, marked embosed, hoisted and fixed in position including connecting up pipes compete all as specified and directed.
S&F 20 mm bore ball valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or ferrule and fixed, compete all as specified and directed.
S & F Gun-metal, globe or gate valves 20 mm bore, with iron wheel head, screwed both ends for iron pipes, compete all as specified and directed.
S&F galvanised mild Steel water tubes, 20 mm bore with all fittings, medium grade, fixed to walls and ceiling or laid in floors compete all as specified and directed.
S&F galvanised mild Steel water tubes,15 mm bore with all fittings, medium grade, fixed to walls and ceiling or laid in floors compete all as specified and directed.
S&F 15 mm bib taps fancy type cast copper alloy chromium plated with crutch with butter fly handle, screwed for iron pipe or brass ferrule, compete all as specified and directed.
S&F 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe compete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm long compete all as specified and directed.
S&F vitreous china wash water closet pan ( pedestal pattern) white fixed in floor including trap, connecting to drain ( or outgoing pipe ) and flush pipe, anti syphonage pipe, flush pipe to pedestal pan including all joints etc.compete all as specified and directed.
S&F plastic water closet seat, white/ coloured, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device compete all as specified and directed.
S&F 10 litres capacity PVC low level valve less syphonic action type flushing cistern white/ coloured, with inlet, ball valve, float and handle including brackets and flushing pipe, compete all as specified and directed.
S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement compete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats white wash complete as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of wall and applying three coats white wash, complete as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint on walls complete all as specified and directed.
Excavation in post holes (or similar holes) each n. exc. 0.5 cum in hard/dense soil and getting out returning filling in and ramming earth or broken rubble mixed with eareth around in layers not exc. 25 cm watering and removing surplus soil to a distance n. exc 50 m and making good surface complete all as specified and directed.
M & L for PCC 1:2:4 type B-2 using 40 mm graded aggregate as in foundation , filling and mass concrete complete all as specified and directed.
M&L for M S Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W (Gde-E-250) quality B, compete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide primer on new or previously untreated steel and iron surfaces of any description over 10 cm wide or girth incl preparation of surface etc., compete all as specified and directed.
M&L for pre- painted galvatume aluminum zinc coating GI based profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws compete all as specified and directed.
M&L for pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall eaves board etc., fixed with self tapping screws compete all as specified and directed.
S&F mild steel work as in hand rails half round or other stock section or core for wooden hand rail straight portion drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing etc., wind ties for roof including securing bolts, post and strut in fencing including cutting tops to shape as directed drilling holes, notching for wire etc. flat iron fillets securing wire mesh including all necessary drilling and bolting and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, comlete all as specified and directed.
M&L for 100mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for chequered cement concrete tiles glossy finish 300 x 300 x 22-25mm thick, with PVC moulding set jointed and pointed in neat cement slurry in floors with mixture of white and grey cement in equal proportion and pigment over 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surface of wall in cement mortar 1:4 mixed with water proofing compound and finish the surface even and smooth without using extra cement complete all as specified and directed.
JASBIR SINGH ANAND
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .