Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAdmitted-Finance | ₹5.9 L | L1 | Admitted-Finance |
| 2 | L2₹6.0 L+₹12,534 (2.12%)Admitted-Finance | ₹6.0 L+₹12,534 (2.12%) | L2 | Admitted-Finance |
| 3 | L3₹6.1 L+₹20,650 (3.50%)Admitted-Finance | ₹6.1 L+₹20,650 (3.50%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Mars Commitments Pvt. Ltd L1 | TRIMURTI INSULATIONS L3 | SAMR SAFETY ENGINEERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying & laying of flame retardant LT PVC synthetic insulation mat suitable for voltage up to 3.3kV with dielectric strength of 30KV, thickness 2.0mm, tensile strength not less than 15 N/sqmm, leakage current not more than 10uA, with temperature variation from 10 to 55 degC, confirming to IS-15652-2006.
NB:a) All allied material such as pu-resin, chemi-bound (hardener), special PVC adhesive, liquid primer and sealing material, tape of matching colour and design to be used to maintain aesthetic look of insulation over the joints and corners are to be provided as required.
b) Test Certificate of the mat shall have to be submitted before starting work.
(Suggested make of Mat: DOZZ / Insulatica 2000 / Shock PRU) | 72 | Sq. Mtr. | 2,900 ₹2,08,800 Lowest | 2,975 ₹2,14,200 | 2,947 ₹2,12,184 |
| 2.00 | Supplying & laying of flame retardant HT PVC synthetic insulation mat suitable for voltage up to 11 kV with dielectric strength of 45KV, thickness 2.5mm, tensile strength not less than 15N/sqmm, leakage current not more than 10uA, with temperature variation from 10 to 55 degC, confirming to IS-15652-2006.
NB: a) All allied material such as pu-resin, chemi-bound (hardener), special PVC adhesive, liquid primer and sealing material, tape of matching colour and design to be used to maintain aesthetic look of insulation over the joints and corners are to be provided as required.
b) Test Certificate of the mat shall have to be submitted before starting work.
(Suggested make of Mat: DOZZ / Insulatica 2000 / Shock PRU) | 122 | Sq. Mtr. | 3,125 ₹3,81,250 Lowest | 3,250 ₹3,96,500 | 3,200 ₹3,90,400 |
Tender Value
₹5.9 L
EMD Value
₹11,864
Closing Date
29 Apr 2026, 3:00 pmClosed
The Librarian
Executive Engineer (Electrical), Works Department, MZ-136, Main Building, IIT Delhi, Hauz Khas, New Delhi 110016
Providing and fixing of fire retardant LT and HT electrical flooring in Transformer Room and HT/LT Panel Room in MSB Sub-Station, RI Park Sub-Station and TIFAC Sub-Station at IIT Delhi
2026_IIT_906124_1
IITD/WORKS (SP- 5289)/2026
Open Tender
Electrical Works
Works
30 days
IIT Delhi Hauz Khas
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹11,864
5 May 2026
22 Apr 2026
30 Apr 2026
22 Apr 2026
29 Apr 2026
22 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying & laying of flame retardant LT PVC synthetic insulation mat suitable for voltage up to 3.3kV with dielectric strength of 30KV, thickness 2.0mm, tensile strength not less than 15 N/sqmm, leakage current not more than 10uA, with temperature variation from 10 to 55 degC, confirming to IS-15652-2006.
NB:a) All allied material such as pu-resin, chemi-bound (hardener), special PVC adhesive, liquid primer and sealing material, tape of matching colour and design to be used to maintain aesthetic look of insulation over the joints and corners are to be provided as required.
b) Test Certificate of the mat shall have to be submitted before starting work.
(Suggested make of Mat: DOZZ / Insulatica 2000 / Shock PRU) | 72 | Sq. Mtr. | - | - |
| 2 | Supplying & laying of flame retardant HT PVC synthetic insulation mat suitable for voltage up to 11 kV with dielectric strength of 45KV, thickness 2.5mm, tensile strength not less than 15N/sqmm, leakage current not more than 10uA, with temperature variation from 10 to 55 degC, confirming to IS-15652-2006.
NB: a) All allied material such as pu-resin, chemi-bound (hardener), special PVC adhesive, liquid primer and sealing material, tape of matching colour and design to be used to maintain aesthetic look of insulation over the joints and corners are to be provided as required.
b) Test Certificate of the mat shall have to be submitted before starting work.
(Suggested make of Mat: DOZZ / Insulatica 2000 / Shock PRU) | 122 | Sq. Mtr. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_952433.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .