Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 CrAccepted-AOC 19 PARKDRIVE MALIBU TOWN SECTOR 47 SOHNA ROAD GURGAON HARYANA 122001 | GURGAON | GURGAON | HARYANA | 122001 | ₹44.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹45.7 CrRejected-Finance | ₹45.7 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹48.5 CrRejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹48.5 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹49.4 CrRejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹49.4 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹50.4 CrRejected-Finance | ₹50.4 Cr | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹51.5 Cr
EMD Value
₹15 L
Closing Date
3 Aug 2023, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-10
CONSTRUCTION OF WSA BASED ON UNIT RISK PRINCIPLE (URP) AT AF STN SARSAWA
2022_MES_570526_2
CEWAC/SAR/T-12/2022-23
Open Tender
Civil Works
547 days
GE (AF) SARSAWA
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE (AF) SARSAWA
₹15 L
HQ CE (AF) WAC PALAM
4 Oct 2023
10 Feb 2023
10 Aug 2023
13 Jun 2023
3 Aug 2023
25 Jul 2023
22 Feb 2023
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of Danger Building including front and rear side brick walls on either side between Centre wall and DB's with permanent specification complete all as specified and as shown on drawings.
Construction of Center Wall with permanent specification complete all as specified and as shown on drawings.
Construction of Traverse Wall with permanent specification complete all as specified and as shown on drawings.
Construction of Static Water Tank 225 KL with permanent specification complete all as specified and as shown on drawings.
Construction of Adm Building with permanent specification complete all as specified and as shown on drawings.
Construction of Guard Room with permanent specification complete all as specified and as shown on drawings.
Construction of Storage Accn Building with permanent specification complete all as specified and as shown on drawings.
Construction of Tubular Parking Shed for (Two Wheelers) with permanent specification complete all as specified and as shown on drawings.
Construction of Tubular Parking Shed for (Cars) with permanent specification complete all as specified and as shown on drawings.
Construction of Fire Point With Plate Form with permanent specification complete all as specified and as shown on drawings.
Construction of Septic Tank (for 50 Users) complete all as as per drawing No CEAF/STD-263/90 sheet No 1/9 to 9/9
Construction of Septic Tank (for 10 Users ) complete all as as per drawing No CEAF/STD-263/90 sheet No 1/9 to 9/9
Construction of Soakage Well including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 1.80M dia X 3.0 M effective depth complete as per Drg No CEAF/STD-301/90 sheet No. 1/4 to 4/4
PRIME COST SUM
Design, supply, installation and testing of 04 (Four) Nos mild steel motorised sliding gate for 6.00mtr opening as per manufactrurer as approved by GE. The each sliding gate shall consists of two panels, each panel shall be 4.00 m in length and 2.50m in ht of MS hollow section( vertical spacing @ 100 mm centre to centre and horizontalmambers @ 1.25m centre to centre) with bottom rail of MS ISCR-50 section and SS rollers of SS Gde-316, for sliding arrangement and 02 Nos Nylon roller on each guilding post to hold the sliding gate in position while opening and closing agaisnt any lateral movement complete all as specified and directed. The manufacturers specification also to be included for smooth functioning of Gate: (a) Gate should be accessible with electronic control panel with integrated manual all weather switch panel for heavy duty operations. ( b ) Easy key lock release through removable cover opening. (c) Internal provision of sensors for smooth operations during opening and closing of the gate. (d) Gate should have a rugged and powerful gear motor in each leaf of gate operated on 230V main power supply, for smooth operation of the gate alongwith its counter-weight. (e) Gate should have suitable opening/closing speed as per manufacturers specifications. (f) Gate should be operated manually in case of power faulure by key oeprating system
(g) independent outdoor panel boards for on/off operations of the gate to be provided for each leaf of gate. (g) Foundation shall br RCC M-25 (Design Mix) for footing & column pedestal. (h) All MS work shall be painted with two coat of syntetetic enamel paint over a coat og primer. Note: (i) Drawings of MS gate as provided by the manufactrurer will be first approved by users through GE and then forwarded to IIT for structural soundness vetting. (ii) Submission of 07 sets of Design calculation/details and drawings of motorised slinding gate complete with electric motor, control gear box and panel etc. duly vetted by IIT in soft copy as well as in hard copy on tracing papers. (iii) Amount inserted is approximate for 04 (four) nos gates and contractor shall quote their percentage over it. Payment will be made as per actual expenditure incurred by contractor enhanced by percentage quoted by the contractor. If percentage quoted by the contractor is more than 15%, it will be considred only 15% i.e. payment will be made by enhancing actual exenditure by 15% only. (iv) Quantities of fondation to be paid as per SSR-2020 Part-II and percentage quoted by contractor shall apply on SSR -2020 Part-II. (v) Quantities other than fondation like MS gates including SS 316 rollers, nylon rollers, other connecting items etc. and motors will be paid based on lowest market quotation & purchase voucher. (vi) Contractor may work out amount as per the percentage which they want to quote and fill up amount in Column No 7 of BOQ.
“Supply lowering testing and commissioning energy efficient submersible pump set complete of suitable discharge rating, 30 mtr head with suitable cap of electric motor but not less than 10HP capacity, electric driven 415 volt or nearest higher rating with stainless steel body and SS impleller complete all as specified and directed.” NOTE:- (i) Amount inserted is approximate and contractor shall quote their percentage over it. Payment will be made as per actual expenditure incurred by contractor enhanced by percentage quoted by the contractor. If percentage quoted by the contractor is more than 15%, it will be considred only 15% i.e. payment will be made by enhancing actual exenditure by 15% only. (ii) Contractor may work out amount as per the percentage which they want to quote and fill up amount in Column No 7 of BOQ.
NOTE: Schedule ‘A’ Part II to XI are under 2.01 to 2.10 are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXACAVATION AND EARTH WORKS” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS ” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “ AREA DRAINAGE WORKS ” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for " ROAD, PATH AND CULVERT WORKS” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “CHAINLINK FENCING & GATE WORKS” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY AND STREET LIGHTS WORKS ” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “ LIGHTENING PROTECTION WORKS” as listed in Schedule ‘A’ Part XI
SCHEDULE `A' PART - XII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION AND FLAME PROOF WIRING
S&F LED light fitting mirror type with high out put diffuser 4 feet, 36 watt 220 V, C including connecting up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed.
S&F LED security light fitting 15 watt, input 110 to 220 volts as per IP 65 luminaries comprising ofrectangular shape, high pressure die cast alunimum housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangment complete all as specified and directed.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 1.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof fittings and accessories such as tees junction boxes, bends duly certified /tested by CMRI Dhanbad suitable for two/three light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete all as specified and directed of followings:-
Two light points controlled by one switch. (1 x 34 for flame proof flood light)
Three light points controlled by one switch. (2 x 34 for internal light)
Supply, install testing and commissioning of flame proof totally enclosed TPN DB 4 way compelte with CMRI certified and flame proof, whether proof complete with emergency off switch with LED indicator as per incoming and ougoing circuit Incoming: (a) MCB TPN 16 Amps 4 pole complete with 10 KA breaking capacity and B curve-01 Nos Outgoing: (a) MCB TPN 10 Amps 4 pole complete with 10 KA breaking capacity and B curve-01 Nos(EOT Crane) (b) MCB SP 06 Amps 1 pole compelte with 10 KA breaking capacity and B curve-03
Supply and fix Flameproof flood light fitting 60 W CMRI certified, recommended for Gas/Vapour Group of IIA & IIB and Zone 1 & 2 IP 65 Protection made of aluminium alloy LM6, complete with all accessories prewired and including connectign up with twin core twisted flexible copper conductor cable with suitable size. Note:- (a) All fittings shall be ISI marked and shall have approval of CMRI dhanbad. (b) Original Test Certificate of Manufacturer shall be produced by Contractor. (c) Lumens efficiency of fitting shall be minimum 100 lumens/watt. (d) PF shall be minimum 0.9.
EOT Cranes
(vii) Testing is to be carried as per IS : 14470. (viii) Factory inspection shall be carried out by rep of AO at factory permises before dispatch and by rep of AO at site after installation.
SUMMER APPLIANCE
Supply and fixing of water cooler electric driven single phase 230V, 50Hz, fully stainless steel body having storage capacity of 80 Ltrs and cooling capacity of 40 litres per hour with stainless steel tank and CFC Free refrigerent (R134a) including all accessories complete all as specified and directed.
STAND BY SUPPLY
Supply, installation, commissioning and testing silent diesel engine driven Gen set 160 KVA (128 KW at 0.8 PF) capacity 415 volts, 3 phase, 4 wire acoustic weather proof enclosure as per CPCB norms and noise level shall not exceeding 75 db at a distance of 1 metre, Engine as per IS-10001/1002 and alternator as per IS-13364 installed on PCC platform as per manufacture recommendation complet comprising the following components: (a) Diesel Engine:- Diesel engine develping suitable BHP, 1500 RPM water cooled engine inclusive of the following standard accessories (i) Spider coupling guard (ii) Fly wheel (iii) Fly wheel housing complete with starter gear ring and coupling (iv) Fuel pipe (v) Air cleaner (vi) Fuel & Lub oil filter (vii) by pass filter (viii) Lub oil pump (ix) Electric Starter 12 Volts DC (x) Battery charging generatory (DC alternator) (xi) Industrial silencer (xii) Lub oil cooler (xiii) flexible pipe for sinencer (xiv) DC voltmeter (xv) lub oil pressure gauge, lub oil/ water temperature guage (xvi) Speedo meter and engine running hours meter (xvi) Display for fault (xvii) Governor (xviii) Battery as per manufacturer recommendation- 01 No (b) ALTERNATOR: Alternator suitable for continous operation generation 160 KVA at 1500 RPM 415 V at NTP, 0.8 power factor 3 phase, 50Hz, self excited and regulated with ball/roller bearing confirming to IS -4722 (c) AMF PANEL: AMF panel, factory made, outdoor double door, cubical type, front open able fabricated out of CRCA sheet 3.15 mm thick of suitable size complete as per manufacturer's specification, suitable for DG set of cap 160 KVA and consisting of the following:-
NOTE: (i) DG Set to comply with latest exhasut emission standards as per Ministry of Environment and Climate change Notification dated 03 Nov 2022 (amended upto date) as under:- Nox-0.40g/kWh; HC- 0.19g/kWh; CO-3.5 g/kWh; PM-0.02 g/kWh; Smoke (light absorption coefficient- 0.7 m-I. (ii) Complete DG set including acoustic enclosure shall eb supplied by the same OEM and test certificate shall be submitted before testing at site
ROAD, PATH , HARDSTANDIGN & CULVERT WORK
Filling the excavated portion with good earth obtained from excavation mixed with cement @3 % by weight ofearth, including rooling & conolidatting formation surfaces to achieve 98% modified proctor density in cutting/filling with 8 to 10 tonne power roller includign filling in depressions which occur during the process of rolling to required level, gradiant, camber and super-elevation etc complete all as specified and as directed.
S&F double legged informatory sign board of size 1.20 M X 1.20 M fixed on single frame , both side and meeting back to back on the stain less steel 50 mm square pipe . The boards are of high intensity grade reto-reflective sheeting of AVERY DENNISON made out of 2 mm thick Alcoband sheet/ aluminium sheet confirming to IS 736 , colour as approved by Engr in Charge on stain less steel squre pipe of size 50x50x3.65 mm square pipe with nut and bolt . The lettering will be computerised cut of high Intensity gradewhite sheeting (AVERY DENNISON) and mechanically fixed on board over vertical post of 50 mm stain less steel square pipe,3.65 mm thick 3.20 M long having 2 nos flat iron strip of 40x5 mm.0.30m long on bottom and fixed with PCC 1:2:4 in post holes of size 0.45x0.45x0.75 m complete all as specified and directed.
EXTERNAL WATER SUPPLY
M&L for Trial bore holes of 200 mm dia in any type of soil/starta including hard stone boulders by means of direct rotary method as directed by Engr-in-Charge.
Drilling, reaming and enlargement of trial bore dug under item srl no.1 here-in-before upto 525 mm dia bore below existing ground level by means of direct rotary method upto and including:-
(a) upto 60 mtr depth
(b) Below 60mtr and upto 130 mtr depth.
Supply, assembling, jointing, lowering and fixing in position of ERW MS seam less plain end casing pipe 200 mm dia (Nominal size) of 5.4 mm wall thickness as per IS-4270: 2000 welded with coupler ring (welding to be done through out the circumference of the pipe and coupler ring both sides) all as specified and directed.
Supply, assembling, jointing, lowering and fixing in position of ERW MS seam less plain end slotted 200 mm dia (Nominal size) of 7.04 mm wall thickness having slot of 1.59 mm wide 3" long assembled and lowered as per location including cutting welding as required complete all as specified and directed.
Electro logging by means of electric logger of the complete tube well of 525 mm dia and submission of report alongwith its interpretation complete all as specified and directed.
Supply and packing with Pea gravel of 3.35 mm to 4.75 mm size as per IS-4097:2008 approved quality as ordered to packed around the casing and slotted pipe in bore well complete all as specified and directed.
Supply and fixing of well cap of 200 mm dia size with locking arrangement on top of casing pipe all as specified and as directed by Engr-in-charge.
Supply and fixing of MS bail plug 200 mm dia size complete all as specified and as directed by Engr-in-charge.
Supply ,fixing and lowering into bore holes centring guides madeout of 16 mm dia MS bar ring suitable for 200 mm bore housing/casing pipe complete all as specified and directed.
Development of tube well by compressed air with compressor of minimum capacity of 1100/300 CFM/PSI complete all as specified and directed.
Yield test of bore well by continuosly pumping for to determine safe pumping yield by V-notch method in presence of rep of AO complete all as specified and directed.
Supply and fixing housing clamp 90 cm long 20 cm wide out of 20 mm thick MS plate for 200 mm dia casing pipe with necessary MS bolts, nuts and washers at ground level in PCC (1:2:4) type B1 using 20 mm graded stone aggregate in block complete all as specified and directed.
Supply and fix GI column pipe heavy grade IS-1239 marked 80 mm bore x 3 mtr long both end flanged joint duly screwed and welded with pipe suspended in deep bore well with groove/cut for submersible cable including rubber gasket and GI nut,bolts on both ends all as specified and directed.
M&L for Calcium Hypochlorite chemical dosing pump 0-100 PSI, gear motored having out put 2 US GPD to 40 US GPD, power 230 volts, 50Hz, RPM 44, self priming non metallic with connecting nuts, ferrules and with all accessories .
M&L for Calcium Hypochlorite dosing system consisting 100 Lts FRP Tank with PR/PRP lid & level gauge alongwith agitator with shaft & blade and connecting accessories all as specified and directed.
M & L for valve pit chamber of size 900 X 900 X 900 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete all as specified and directed.
M & L for valve pit chamber of size 300 x 300x300 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete all as specified and directed.
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 50 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support, well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:- (a) INCOMING :- (i) MCB TPN 40 Amps,415 V, 10 KA -01 Nos.(ii) Digital type Multifunctional meter to measure Amp,Voltage-01 No (b) OUT GOING :- (i) MCB TPN 40 Amps, 415 V, 10 KA - 01 Nos. (ii) MCB SPN 10 Amp 240 V- 02 Nos (iii) Automatic star delta starter suitable for 10 HP motor drytype complete with single phase preventer having provision for auto cut for over/under & reverse phasing etc-01 No Note:- (i) Panel shall be mounted on brick work plate form duly plastered and PCC copping work on top surface , height shall be 0.45 m above the GL and 0.40 M all around the FPB (ii) All incoming and out going cables shall be connected with suitable size of cable luggs and cable galands.
M&L for fabrication , installation testing MS pipe distribution header of under mentioned size including branches complete with welding work with two coat of anti corrosive spray paint over a coat of red oxide primer complete with end plates PCC work and FI clamps with suitable nut,bolt for securing of header pipe in PCC blocks as per following. Main Header- Main header of size 200 mm bore 4.0 mtr long made of MS pipe 6.3 mm thick complete with end plates 10 mm thick welded at both ends Incoming- Incoming branch of size 100 mm bore MS pipe from borewell to headerwith one sluice valve 100 mm bore PN 1.6 complete - 01 nos Out going-Branch connection of size 80 mm bore MS pipe with one sluice valve 80 mm bore PN 1.6 each branch complete -04 sets
Supply and fix cast iron Air Valve with single air outlets, confirming to IS 14845 of size 50 MM dia bore and fixing up in cast iron water supply mains of size 50 mm dia all as specified and directed.
M&l for water potable chemical analysis test from a govt approved lab inculding collecting the water from the given point into a glass/plastic jar, taking sample to the lab for testing and submiting the report as per the direction of Engineer -in - charge.
S&F submersible cable flat copper conductor PVC insulated and PVC sheathed 6.0 sqmm 3-core 415 V, 1100 V grade fixed to column pipe with suitable clamps jointing material complete.
Supplying, laying in trenches, under floor, under road, connecting, jointing and testign ductile iron pressure pipe centrifugally cast ISI marked, with socket and spigot ends confirming to IS 8329 (2000) in standard length, of K7 specification with outside zinc coating complete with EPDM rubber ring as per IS 5382 of 80mm bore. Make- Tata metallic/Jindal/Electrosteel
Supply and fix ductile iron fittings of size upto 80mm bore for spigot and socketed pipes e.g. bends (any type, radius and angle). Tapers any type (Straight, end, increasing, decreasing or double socket etc). Tee pieces single branch, 'Y' junctions double branches, crosses (all sockets or socket and spigot) collars caps and plugs conforming to is complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, installation, testing & commissioning & of transformer step down outdoor type 11 KV/433 volts three phase 50 Hz, 160 KVA capacity core type double copper wound oil immersed , naturally cooled, oil natural- Air natural (ONAN), with external cooling tubes/fins, delta connection on primary side (HV side) and star connected to secondary side (LV side) in accordance with vector group Dyn 11 with neutral brought out on secondary side (LV side) and having tappings at ± 7.5% in steps of 2.5 % on HV side to be changed by the means of hand operated off load tap changing gear. Max losses at 50 % load shall not exceed 570 watt and max losses at 100% load shall not exceed 1700 watt. The max temperature rise should not exceed 35°C in oil and 45°C in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40°C. The transformer shall be IS 1180 (Part-I 2014) including initial filling of transformer oil confirming to IS-335 and shall comprise of following-:
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 400 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under: (FPB-I )
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 320 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:- (FPB-2 )
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet outdoor type cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 200 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:- (FPB-3 )
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 200 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:- (FPB-4 )
Supply, install, test and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 400 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 200 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:- ( FPB-05 )
Note for item no 9.03 to 9.13- (i) All MCCB shall be with adjustable Thermal magnetic setting (TMD). (ii) The borad shall be epoxy polyster powder coated with structure siemens gray shade RAL-7035(iii) Sheet metal works shall be processed with nine tank process i.e. degreasing, water rinsing, activation, derusting, water rinsing, phosphating, water rinsing, passivation and water drying.(iv)Busbar shall be of electrolytic grade aluminium and shall be insulated with Red, Yellow, Blue and black colour heat shrinkable PVC sleeves.(v) Earth bus shall run throughout the length of the panel at the bottom of the panel.(vi) Each feeder shall be provided with individual inscription plate made out of black anodized Al/polycarbonate sheet with engraved/painted letters. (vii)Power switches/MCCB's will be provided with door operating mechanism, door interlock and padlocking feature.(viii ) Danger notice board with conventional skull & bone sign in postman red to be provided on front & rare side.(ix) All incoming & outgoing feeder shall be provided with cable glands at entry & exit of cable.(x) all MCCB's to be provided with rotary operating handle.
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
S&F non metallic junction box made out of thermoplastic of size 250x250x160 mm for street light poles with connector for connection incoming and outgoing cables including provn of 01 No MCB SP 2.5 Amp to control the pole light circuit including 04 x aluminium bus bars strips 150x30x3mm of size mounting on the insulator and fixing clamp made of FI 25x3 mm with back strip with suitable nut, bolts and washers including suitable size of double compression cable glands for incoming and outgoing cables complete all as specified and directed.
S & F PVC insulated copper wire 1.5 sqmm 3 core for street light fitting from juction box to fitting comple along with suitable clamps all as specified and directed.
Supply and fixing of Automatic street light switch using infrared Sensor based Nature Switch for automatic switching of street light. Nature switch operating should be based on Nature switch lux level required illuminare level for switching ON is < 30 lux and for switching Off > 10 Lux. The sensor should also have part night opeation facility for 4,5,6....11 & 12 hours. The sensor alongwith suitable power contactor, Incoming outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of Rust proof, electric shock proof, termite proof and FR grade SMC juction box confirming to IP54.Timer should also have provision of auto/manual toggle switch. The circuit should be suitable to the three phase load of 6 KW with contactors (3 Nos) & incoming-outgoing MCBs (3 Nos each) rating of 20-25 Amps & circuit wiring of minimum 10 Sqmm complete all as specified and directed.
S&F static discharge system made from 600X600X3.15mm thick copper plate in floor with 04 Nos 15mm dia and 100mm long MS bolts and nuts and handle made of 20 mm dia copper rod 300mm long made 'U' shape and grouted in wall incl connected with earth plate with copper strip 20X3mm size complete.
M&L for Construction of platform with steps for transformer of size 2.5 x 2.5 x 1.5 mtr with following speifications:- (a) Earth work in soft/loose soil. (b) 15 cm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as lean concrete in foundation. (c) Brick work with sub class 'B' brick built in cement mortar 1:4. (d) 75 mm thick PCC 1:2:4 type D2 using 20 mm graded aggregate over brick platform. (e) Chain link fencing post of size 40 x 40 x 6 mm of height 1.80 mtr at 2 mtr c/c around brick platform including excavation and earth work 30 cm embedded portion of angle iron in PCC 1:2:4 type B2 of size 60 x 60 x 60 cm. (f) Chain link fencing of height 1.8 mtr made out of GI wire not less than 3mm and pitch not more than 75mm (g) Angle iron gate using 40 x 40 x 6 m angle iron of size 2 x 1.5 m with vertical flat 25 x 6 mm @ 10 cm c/c including hanging & locking arrangement. (h) 15 mm thick plaster in CM 1:6 on brick masonary platform. (j) All exposed surfaces of steel work shall be given two coats of synthetic enamel paint over a coat of red oxide primer. (k) Stair case of brick masonary for easy access to the platform.
Supply & fixing HT lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 10 KA suitable for 11 KV complete all as specified and directed.
FENCING
S&F for 1000mm dia Punched tape concertina coil any type coil size of any type of standards,rails etc including provision of mild steel(annealed) binding wire complete all as specified and directed.
S&F Notice board of size 0.90 M x 1.20 M complete with following specifications: (i) Flocked fabric (velvet) of approved colour over soft board core of thickness 6mm for pinning up notice and information (ii) Anodised aluminium frame for board and top cover. (iii) Transparent acrylic sheet in top cover (iv) Single coninious hinge swing type top cover (v) Flush mount locking arrangement with 02 sets of keys. (vi) Concealed holes or brackets on corners for mounting the board on wall.
NITYA NAND AND SONS CONTRACTORS PVT LTD
J.D.Builders
Brahma Infra
VIJAY JINDAL BUILDERS PVT LTD
B D Raizada Projects Pvt Ltd
Agarwal Jagdish Construction Company Private Limited
M M SHAWL Engineers and contractors pvt ltd
NSC Projects Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid