Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
24 Aug 2026, 11:00 amDue today
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The Similar nature of works for this instant tender shall be "The Similar nature of works for this instant tender shall be "Any work of supply, installation, testing, commissioning, and/or repairs and maintenance of split/window/cassette-type room air conditioners." OR Any work of supply, installation, erection, testing, commissioning, and/or repairs and maintenance of centralized conventional/packaged/HVAC/VRF/VRV-type air conditioning plant/plants with/without ducts ." The tenderer should have executed the similar nature of works in Central/State Government department or PSUs of Central /State Government."
46 conditions · 5 needing a document upload
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE SUBMITTED.
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
At LMG Division Provision of RAC (Split AC's) in SS/SM's chamber/rooms.
EL-LM-26-27-O9-RT-01
EL-LM-26-27-O9-RT-01
Open
Works - General
90 Days
Hojai, Assam
₹0
₹2.0 L
31 Jul 2026
31 Jul 2026
10 Aug 2026
21 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,02,25,312.04 | ||
| — | 136.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1.5 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Inverter Type - Cooling only Room Air conditioners (RAC) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).All consumables (GI Stand for outdoor units where required) for fixing arrangement to be provided and executed by the firm as per direction of engineer in charge at site. The RAC shall comprise Indoor Unit (IDU) with evaporator, blower, filters, controls and casing, and Outdoor Unit (ODU) with compressor, condenser, fan, refrigerant and associated electrical and protection components. " The outdoor unit of the Room Air Conditioner (RAC) shall be installed on the non-platform side, with an appropriate outlet water drainage pipe arrangement." | — | — | — | 74,39,200 | |
| — | 300.00 | — | — | ||
| Supply and erection of Refrigerant Copper pipes of 6.4mm (1/4")dia to integrate outdoor / indoor units.The rate shall inclusive with Nitrile rubber insulation class O (tubular form) - 19mm thick for Suction lile &13mm thick for liquide line. Cu Make:- Rajco/ Mandev/ Totaline/ Maxflow Insulation Make:- Kflex/ Aeroflex/Armacell | — | — | — | 2,63,589 | |
| — | 300.00 | — | — | ||
| Supply and erection of Refrigerant Copper pipes of 12.7mm (1/2") dia to integrate outdoor / indoor units.The rate shall inclusive with Nitrile rubber insulation class O (tubular form) - 19mm thick for Suction lile &13mm thick for liquide line. Cu Make:- Rajco/ Mandev/ Totaline/ Maxflow Insulation Make: Kflex/Aeroflex/Armacell | — | — | — | 3,43,698 | |
| — | 136.00 | — | — | ||
| Supply, installation, testing & commissioning of wall mounted 5 KVA automatic voltage stabilizer having working range - 140V to 300V, Input range - 165V to 285V, Output range - 200V to 240V as per direction of EIC at site.( Make - Miracle or Similar model ofVertex/Hitek/V-Guard) | — | — | — | 5,50,908.8 | |
| — | 136.00 | — | — | ||
| Supply & wiring of Room Air Conditioner(RAC) point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x 4 sq.mm PVC insulated unsheathed and multi-stranded FRLS-HR copper cable on wall complete with 1 No. 25 A motor starter switch, 1 No. 32A SP mini MCB, C-series, 3kA, 6-16 A 3 pin shuttered socket with 3M concealed unbreakable GI modular box, 3 M cover plate etc. as required at site including 1sq. mm unsheathed copper cable as earth continuity wire. | — | — | — | 1,10,164.08 | |
| — | 136.00 | — | — | ||
| Supply, fixing, testing and commissioning of 6 Way SPN DB Conforming to IS 8623-1 & 3,IEC 61439-1 & 3, IK 08 single door, in CRCA Sheet steel, RAL 9003,Powder Coated Board IP43 with i)32 amp, 30mA DP RCBO, Conforming to IEC 61009-1, IS 12640-2, EN 61009-1, Short circuit Breaking Capacity - 10kA =1 no.(ii) 32 amps DP C series MCB -01 no. (iii) 16 Amps SP C series MCB - 02 nos. The SPN MCB DB whole arrangement should be properly concealed on wall and earthing properly as per direction of engineer in charge at site. | — | — | — | 9,62,166 | |
| — | 1500.00 | — | — | ||
| Supply, fitting and laying of Single core 4 sqmm Flame Retardant Low Smoke Heat Resistant PVC insulated industrial grade multistrand copper conductor(unsheathed) flexible cable voltage grade upto1100 Volt.(Conforming to IS 694:2010) | — | — | — | 96,570 | |
| — | 136.00 | — | — | ||
| Supply and erection of earthing made of B class GI pipe of 4000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip(50x6)mm should be welded with the earth pipe. The pipe is provided with tapered casing at the lowerend in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil.Where soil restivity is high,earth restivity enhancing material may be used,Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. This will supersedes the earlier drawing no. PCEE/ELG/DRG/2024/1 dated 30.09.24 & CEE/STD/1 As per Drg.No.: PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | — | — | — | 1,84,118.16 | |
| — | 1200.00 | — | — | ||
| Supply and wiring of Sub-main line by 2x10 sq. mm.PVC insulated unsheathedand multi-stranded FRLSCopper Cable confirming toIS 694/1990 through suitablesize of PVC casing cappingwith earth continuity bycopper wire of 1 sq. mm.(One RM consists of 2 wires). Casing/capping shall be fixed on the wall ceiling by MS(6X40MM) screw at an interval of not more than 300 mm. | — | — | — | 1,59,348 | |
| — | 2500.00 | — | — | ||
| Supply and wiring of sub-main line cassing capping by2x2.5 sq. mm. PVC insulatedunsheathed and multistranded FRLS Copper Cableconfirming to IS 694/1990through suitable size of PVCcassing capping with 1sq. mmunsheathed copper cable asearth continuity wire . | — | — | — | 1,15,550 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-09-RT-01_1.pdf
ATTACHMENT
_WPMSFILES__0525038849f1011.pdf List of AC
ATTACHMENT
_WPMSFILES__0525038849f1011.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].