| 1 | L1₹58.7 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹58.7 L Quoted ₹58.9 L | L1 | Accepted-AOC Being the lowest and reasonable bidder |
| 2 | L2₹61.8 L+₹2.8 L (4.82%)Rejected-AOC | ₹61.8 L+₹2.8 L (4.82%) | L2 | Rejected-AOC Being the other than lowest bidder |
| 3 | L3₹62.5 L+₹3.6 L (6.13%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹62.5 L+₹3.6 L (6.13%) | L3 | Rejected-AOC Being the other than lowest bidder |
| 4 | L4₹63.2 L+₹4.3 L (7.28%)Rejected-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹63.2 L+₹4.3 L (7.28%) | L4 | Rejected-AOC Being the other than lowest bidder |
| 5 | L5₹66.4 L+₹7.4 L (12.6%)Rejected-AOC | ₹66.4 L+₹7.4 L (12.6%) | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹87.5 L
EMD Value
₹1.6 L
Closing Date
8 Mar 2024, 6:00 pmClosed
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
PROVN OF CONVERSION FOR LT OH LINES TO UNDERGROUND CABLE IN PERIMETER AND SECURITY LIGHT WITH ALLIED WORK AT REASI MIL STN AND CHASANA UNDER GE NAGROTA
2024_MES_639463_1
CWE/NGT-44/2023-24
Open Tender
Civil Works
Item Rate
182 days
Reasi and Chasana
As per NIT and tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE Nagrota
₹1.6 L
Yes
6 May 2024
29 Jan 2024
15 Mar 2024
29 Jan 2024
8 Mar 2024
26 Feb 2024
29 Jan 2024 - 12 Feb 2024
Amount
Dismantling and taking down old unserviceable ACSR conductor of any type/size complete all as specified and directed by Engineer in Charge.
Dismantling and taking down old unserviceable insulator any type and any size complete all as specified and directed by Engineer in Charge.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for laying of cable or pipes, trimming the sides, forming bottom surfaces to required level, n.exc 10sqm on plan and getting out, complete all as specified and directed.
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 20 cm thick complete all as specified and directed.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete all as specified and directed.
M & L for dry sand cushioning to under ground cable laid in trenches for laying of HT/LT UG cables 8 cm wide before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2009) all as specified and directed. Note: Punned thickness shall be measured and paid to the contractor.
M&L for un-reinforced precast concrete cable cover of size 300x180x40mm for protection of cable, laid transversally along the length of cable, complete all as specified and directed.
Supply, laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3.5 core complete all as specified and directed .
Supply, laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 50 Sqmm 3.5 core complete all as specified and directed .
Supply, laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 25 Sqmm 3.5 core complete all as specified and directed .
S&F GI tubing 20mm bore light grade, fixed to street light pole for connection, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed.
S&F copper wire with 3 core 2.5 sqmm PVC insulated (flexible) 1100 volts grade, connected from junction box to street light complete all as specified and directed.
Supply and Fix, shock proof, rustproof, termite resistant, weather proof, fire retardant - Class FV-0 as per IS:11731 Part-II or V-0 as per UL-94, high heat distortion temperature (200°C as per IS:10192), pole mounted Junction box, minimum size (Internally) 250 mm (H) x 200 mm (W) x 105 mm (D), including provision of 01 (One) No. electrolytic aluminium bus bar, 10 Amps, supported on non-hygroscopic fibres and brass screws for mounting with and including 01 (One) No. miniature circuit breaker (MCB) single pole, 240 Volts, 10KA, 6 Amps complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
S & F Bracket for street light fitting made out of tubing 50 mm dia, med grade 2' x 1-1/2' 135 degree bend with cutting, welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings complete all as specified and directed by Engr-in-charge.
Supply and fixing GI tubing 40 mm dia light grade laid under floors/road crossing, fixed to walls and ceiling as cable protection pipe all as specified and directed by Engr-in-Charge.
Supply and fixing GI tubing 50 mm dia light grade laid under floors/road crossing, fixed to walls and ceiling as cable protection pipe all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and Fix, Astronomical Time Switch with enclosure all as per Cat No. 'T2DDT7' with 3 Pole Power Contactors, Type MNX 25, AC3 Rating 25 A and AC1 Rating 45 A, all as per Cat No. 'CS94110' of Make 'L&T or equivalent as per list of makes given in particular specifications complete all as specified and directed.
S&F 7mtr high hot dip galvanised octagonal pole made up of 3mm thick sheet along with nuts, bolts, bracket, suitable size base plate and 4 Nos of J type foundation bolts with template as suitable for pole, complete all as specified and as per manufacturer's instructions. Make:- Bajaj, Philips, CG. Note: Foundation of pole shall be as per manufacturer's design and recommendations. The cost of earth work, foundation is deemed to be included in the quoted rate.
S&F commissioning and testing of outdoor cubical type LT Feeder pillar box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V, 3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell having TPN aluminium busbar mounted in porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring, Powder coated complete all as specified a nd directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. Angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
Incoming:- (a) MCCB 200 Amp 4 pole 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No (b) Alum bus bar 200 Amp TPN - 01 Set (c) Digital Multifunction meter showing:- V, I, PF, Hz etc with suitable CT - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a) MCCB 160 Amps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 03 Nos (b) MCCB 4 Pole, 100 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No (c) MCCB 4 Pole, 63 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu (Make - Siemens/Legrand)- 01 No
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25x4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
S&F commissioning and testing of outdoor cubical type LT Feeder pillar box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell, having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring, Powder coated complete all as specified and directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. Angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
Incoming:- (a) MCCB 160 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 03 Nos (b) Alum bus bar 200 Amp TPN - 01 Set (c) Digital Multifunction meter showing:- V, I, PF, Hz etc with suitable CT - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a) MCCB 100 Amps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand)- 01 No (b) MCCB 63 mps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No
Material and labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of pole complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
S&F commissioning and testing of CPRI approved outdoor cubical type bus bar chamber box of size 0.5Mx0.8Mx0.60M depth,(HxBxD) outdoor type alongwith one incoming MCCB 100 A 4 Pole 25 KA factory fabricated made out of CRCA sheet of 3.15 mm thick ,fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 100 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, system including provision of suitable cable glands, duly powder coated complete all as specified and directed.
S&F commissioning and testing of outdoor cubical type LT Feeder piller box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell and 2mm thick for inner shell having MS section not less then 40x40x6 mm thick having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, Powder coated complete all as specified and directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer
Incoming:- (a) MCCB 160 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 03 Nos (b) Alum bus bar 200 Amp TPN - 01 Set (c) Multifunction digital meter (consisting of Voltage 0-500 volts, Current 0-300 Amp, PT and CT (Frequency, PF, kWh, kVA parameter) - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a) MCCB 125 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal Magnetic type setting Ics = 100% of Icu (make- Siemens/ Legrand) - 01 No (b) MCCB 63 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal Magnetic type setting Ics = 100% of Icu (make- Siemens/ Legrand) - 01 No
Note:- Schedule of credit Rs. 20,000.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
SHSS ASSOCIATES
kailu construction co
vijay kumar gupta and co
RAVI KUMAR
PROACH ASSOCIATES BUILDERS & ENGINEERS
FANGALIA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .