| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.3 L+₹5,000 (0.60%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.5 L+₹18,000 (2.17%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.6 L+₹30,000 (3.61%)Rejected-Finance R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹9.4 L+₹1.1 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
28 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 WORKS ENGRS
HQ 134 WORKS ENGRS, PIN-914134, C/O 56 APO
PROVISION OF 82.5 KVA GENR SET AT AWANTIPUR UNDER GE 861 EWS
2020_MES_382499_1
134 WE-51/2020-21
Open Tender
Civil Works
Item Rate
180 days
SRINAGAR
PLEASE SEE TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE 861 EWS
₹19,000
Yes
18 Dec 2020
30 Sept 2020
30 Oct 2020
30 Sept 2020
28 Oct 2020
15 Oct 2020
60 days
Amount
Supply, installation,testing and commissioning diesel engine driven generating set water cooled of capacity 82.5 KVA, 415 volts, 0.8 power factor at NTP, mounted on common base plate with flexible coupling, with and including of acoustic insulated chamber to maintain noise level as per CPCB norms for capacity of 82.5 KVA DG set complete in built with all accessories and totally enclosed type with silencer pipe protected with asbestos rope from engine to outside the building, 0.5 mtr and independently supported AVM pads, battery starter type foundation as per manufacturers design, DG set should be capable of operating in temp range of (-) 15 degree Celsius to (+) 35 degree Celsius with and including the following :- ( Including foudation of DG set as per manifacturer size and specification ) ...contd/-
(A) Prime Mover Vertical diesel engine of suitable capacity 82.5 KVA at NTP, water cooled type closed, circuit as per BS-649 or IS-10002, direct injection type turbo Charged , battery starting system having rated speed 1500 RPM. The DG set shall be capable of running 24 hours continuously with 10% over loading for one hour in every 12 hours run as per BS- 5514/BS-649. Engine shall be equipped with all standard fittings as per manufacture’s recommendation & mounted common plate through flexible coupling with following fitting: - (i) RPM cum hour meter (ii) Battery charging ammeter. (iii) Ignition key and starting with button switch. (iv) Lubricating oil pressure gauge. (v) Mechanical / electric governor controlling. (vi) Oil temperature gauge (vii) Safety control with tripping facility for the following (a) Low lubricant oil pressure (b) Over speed (c ) High water temprature (viii) Starting equipment comprising of following:- (a) Battery as per manufacturer recommended Make :- Exide/Luminus/Amron. (b) Battery, charging alternator with inbuilt regulator. (c) Battery leads of copper cable of suitable size brass thimbles and terminals. Make of engine – Kirloskar/Mahindra/Cummins ...contd/-
(D) Other fitting :- (a) Battery Charger- Battery charges having electric circuit consisting of triodes, rectifies, capacitor and resistance etc. The battery charges should be able to charge the battery at all the time whenever electric supply given to battery charges through control panel or electric power point. (b) Fuel tank made up of MS Sheet of suitable capacity as per manufacturer’s instructions capable to store fuel for 12 hours running of DG set fixed as per manufacturer`s design and return fuel pipe with all pipes connecting upto fuel pump including oil level indicating gauge, drain plug for cleaning and air vent plug etc.
M&L for earthing complete with GI steel earth plate electrode 600x600x6.3mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip earth lead of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel all as shown on electrical plate No 5 of MES Sch 2009 Part-I connected to earthing test point and testing on completion with and including necessary excavation and earthwork, earth electrode, earthing lead from electrode to eqpt/sub stn , adequated quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 using 20mm graded black trap/granite/basalt stone aggregate, 40mm thick cover reinforced with 8mm dia bar 4 Nos both way with 12mm dia round bar handle, GI light grade protection pipe 15mm bore with funnel and wiremesh and 15mm dia GI light grade earth lead protection pipe complete all as specified and directed by Engr-in-Charge. Notes:- (i) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department.
M/S A.N CONSTRUCTIONs
M/S Mohammad Saleem and Co
M/S LATIF AHMAD BABA CONSTRUCTION
M/S MARVEL ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .