Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC accepted | |
| 2 | L2₹4.3 L+₹57,530 (15.5%)Rejected-AOC FIRST FLOOR GEETA COMPLEX ROHTAK ROHTAK ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | L2 | Rejected-AOC rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical rejected |
Tender Value
₹4.2 L
EMD Value
₹8,360
Closing Date
7 Nov 2024, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
Micro processor based 2 wire fault, public adress system, online UPS, intelligent Analog Addressable type Smoke Detector, addressable heat detector, intelligent Analog Addressable type Manual Call Point, PVC pipe (20mm dia) and PVC FRLS single core x
2024_HRY_408122_1
20240C90C2D6 07E8 42EB 8629 AE81BD915C6E667BAR
Open Tender
Electrical Works
Works
30 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹500
₹8,360
Yes
10 Mar 2025
30 Oct 2024
8 Nov 2024
30 Oct 2024
7 Nov 2024
30 Oct 2024
Amount
NS Items
Supply and Erection of Fire Extinguishers complete in all respect. Make:- Safex / Minimax / Cease Fire Co2 Type Fire Extinguishers 4.5kg Cap with BIS 15683
Supply and Erection of Fire Extinguishers complete in all respect. Make:- Safex / Minimax / Cease Fire Co2 Water 9Ltr Cap ISI marked
Supply and Erection of Fire Extinguishers complete in all respect. Make:- Safex / Minimax / Cease Fire ABC 6KG Cap ISI Mark 15683
Supply, installation, testing and commissioning of minimum 500 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer in charge. Make: - National / Kheraj
Supply, Installation, Testing and Commissioning of Micro Processor Based 2 Wire Fault Tolerant, Networkable Type Fire Alarm / Detection Control Panel (having no. of loops to suit minimum 20% extra over the nos. of fire detectors). The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must have access levels and Panel should be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ min. 5.7`TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 40 LED Indicators. The Panel shall have Serial Ports. Panel Power supply should be 24V-150W.The panel shall have a built in power supply, battery charger capable of running for a minimum 24 hours operation complete as required . RH 5% - 95% non-condensing and conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable Type Smoke Detector that combine Photoelectric and fixed temp thermal with dual LED, hard addressable having rotary decade address switches, with mounting base complete as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the Job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interference and report to the panel current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isolators may be considered with an additional isolator module per detector. Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect. Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Addressable Loop Powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC and Operating Temp: -20 ºC to plus 60 ºC and Operating voltage 15 to 30 Vdc. RH (=95%. Shall be EN54/UL/VDS Certification Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Addressable Type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable complete as required conforming to BS5839 standards and duly approved by EN54/UL/VDS/BSA with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in charge of the work. Make: - Honeywell Morley / Siemens Cerberus / Bosch FPA / GST
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board Photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make: - Glolite / Pearl/ Omex
Supply and Erection of PVC FRLS unsheathed Copper Conductor Cable Two Core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Make Polycab / Havells / Finolex 2 core PVC unsheathed Copper Size 1.5 Sqmm
Arora Telecommunication (BID ID -1164252)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .