Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-Finance NEAR 43A 7B P M ROY RD 17 1A 7 3 114 CHETLA RD AND 27G 109H ALIPORE RD IN WARD NO 82 | KOLKATA | WEST BENGAL | 700001 | ₹6.6 L | L1 | Accepted-Finance Accepted, Subjected to Board |
| 2 | L2₹6.7 L+₹13,625.20 (2.08%)Accepted-Finance 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | ₹6.7 L+₹13,625.20 (2.08%) | L2 | Accepted-Finance Accepted, Subjected to Board |
| 3 | L3₹8.9 L+₹2.3 L (35.2%)Accepted-Finance | ₹8.9 L+₹2.3 L (35.2%) | L3 | Accepted-Finance Accepted, Subjected to Board |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | Vinod Kumar Aggarwal L2 | D P & CO L1 | TARUN THAKUR L3 |
|---|---|---|---|---|---|---|
| 1.00Upgradation of Street light C.B. Hospital Road near Military Hospital upto C. B. Hospital, Kasauli Cantt | ||||||
| 1.01 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1 6 meter in deep gett1ng out in hard/dense soil for stay assembly/laying of cable/erection of poles etc, complete all as specified and directed by Engr-in-charge. | 62.44 | Cum | 380 ₹23,727.2 Lowest | 400 ₹24,976 | 530 ₹33,093.2 |
| 1.02 | Returning, filing in including spreading, levelling. watering and well ramming in layers n exc 25cm thick complete all as specified and directed by Engr-in-charge | 54 | Cum | 60 ₹3,240 Lowest | 290 ₹15,660 | 345 ₹18,630 |
| 1.03 | Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point compete all as specified and directed by Engr-in-charge | 9 | Cum | 60 ₹540 Lowest | 400 ₹3,600 | 350 ₹3,150 |
| 1.04 | M&L PCC Type C-2 1:3:6 using 40 mm grade stone agregate as in foundation filling and mass concrete for erection of poles in a pit of size 60cmX60cm X140cm. | 7.56 | Cum | 4,400 ₹33,264 Lowest | 4,900 ₹37,044 | 9,200 ₹69,552 |
| 1.05 | M&L PCC Type B-1 1:2:4 using 20 mm grade stone agregate as in copping to be done around the steel tubular pole upto the height of 45 cm from the ground level and 30 cm in dia complete all as specified and driected by Engr-in-Charge. | 0.54 | Cum | 7,600 ₹4,104 Lowest | 8,000 ₹4,320 | 12,000 ₹6,480 |
| 1.06 | M&L for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board 1100 volts grade heavy duty cable with XLPE insulated stranded aluminum conductor served with inner sheathing of PVC tape, armoured with aalvan1sed steel Wire or tape and overall PVC sheathed 10.0 Sqmm x 4 core with required aluminum cable lugs complete all as specified and directed by Engr-in-charge | 400 | RM | 215 ₹86,000 Lowest | 250 ₹1,00,000 | 540 ₹2,16,000 |
| 1.07 | S&F GI tubing light grade 50mm bore, ISI marked, for cable protection at road crossing complete all as specified and directed by Engr-in-charge. | 15 | RM | 450 ₹6,750 | 400 ₹6,000 Lowest | 850 ₹12,750 |
| 1.08 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant compete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete al as specified and directed by Engr-in charge. | 15 | Each | 2,450 ₹36,750 Lowest | 3,540 ₹53,100 | 2,600 ₹39,000 |
| 1.09 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.50 metres long) including two coats of aluminum paint /black paint over coat of red oxide complete all as specified and directed by Engr-in-charge. | 15 | Each | 26,000 ₹3,90,000 | 21,380 ₹3,20,700 Lowest | 22,500 ₹3,37,500 |
Tender Value
₹7.4 L
EMD Value
₹18,425
Closing Date
4 Jun 2026, 5:00 pmClosed
Chief Executive Officer
Office of Cantonment Board Kasauli
Upgradation of Street light C.B. Hospital Road near Military Hospital upto C. B. Hospital, Kasauli Cantt
2026_DGDE_765248_1
CBK/PW/925
Open Tender
Street Lighting
Item Rate
365 days
Kasauli
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Chief Executive Officer
₹18,425
27 Jul 2026
14 May 2026
6 Jun 2026
14 May 2026
4 Jun 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Upgradation of Street light C.B. Hospital Road near Military Hospital upto C. B. Hospital, Kasauli Cantt | |||||
| 1.01 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1 6 meter in deep gett1ng out in hard/dense soil for stay assembly/laying of cable/erection of poles etc, complete all as specified and directed by Engr-in-charge. | 62.44 | Cum | - | - |
| 1.02 | Returning, filing in including spreading, levelling. watering and well ramming in layers n exc 25cm thick complete all as specified and directed by Engr-in-charge | 54 | Cum | - | - |
| 1.03 | Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point compete all as specified and directed by Engr-in-charge | 9 | Cum | - | - |
| 1.04 | M&L PCC Type C-2 1:3:6 using 40 mm grade stone agregate as in foundation filling and mass concrete for erection of poles in a pit of size 60cmX60cm X140cm. | 7.56 | Cum | - | - |
| 1.05 | M&L PCC Type B-1 1:2:4 using 20 mm grade stone agregate as in copping to be done around the steel tubular pole upto the height of 45 cm from the ground level and 30 cm in dia complete all as specified and driected by Engr-in-Charge. | 0.54 | Cum | - | - |
| 1.06 | M&L for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board 1100 volts grade heavy duty cable with XLPE insulated stranded aluminum conductor served with inner sheathing of PVC tape, armoured with aalvan1sed steel Wire or tape and overall PVC sheathed 10.0 Sqmm x 4 core with required aluminum cable lugs complete all as specified and directed by Engr-in-charge | 400 | RM | - | - |
| 1.07 | S&F GI tubing light grade 50mm bore, ISI marked, for cable protection at road crossing complete all as specified and directed by Engr-in-charge. | 15 | RM | - | - |
| 1.08 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant compete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete al as specified and directed by Engr-in charge. | 15 | Each | - | - |
| 1.09 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.50 metres long) including two coats of aluminum paint /black paint over coat of red oxide complete all as specified and directed by Engr-in-charge. | 15 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.61 MB
streetlight.pdf
Tender Documents • 1.59 MB
BOQ_857080.xls
BOQ • 0.29 MB
boq.rar
PDF • 0.08 MB
corrigendum.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .