Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹4.5 L+₹22,895 (5.41%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.8 L+₹59,398 (14.0%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Sai Electrical Works L2 | RAVI RAJ ELECTRICALS L1 | S SAMATHNAM L3 |
|---|---|---|---|---|---|---|
| 1.00Wiring for circuit / sub main wiring along with earthwire with the following size of FR PVC insulated multistrand copper conductor cable in surface / recessed PVC conduit as required. (CPWD - 1.14.3) | ||||||
| 1.10 | 2 x 6 sqmm along with earth wire 1 x 6 sqmm. | 224 | Rmt | 495 ₹1,10,880 | 280 ₹62,720 Lowest | 389 ₹87,136 |
| 1.20 | 2 x 2.5 sqmm along with earth wire 1 x 2.5 sqmm. | 877 | Rmt | 245 ₹2,14,865 | 200 ₹1,75,400 Lowest | 288 ₹2,52,576 |
| 2.00Supplying and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, inter connections, phosphatised and powder painted including earthing etc.as required (but without MCB/RCCB/Isolator) etc. as required. 12 way double door Make: Legrand' / Havells/L&T or equivalent | ||||||
| 2.10 | 12 way double door Make: 'Legrand' / Havells/L&T or equivalent | 2 | Each | 1,800 ₹3,600 Lowest | 2,300 ₹4,600 | 2,155 ₹4,310 |
| 2.20 | 8 way double door Make: 'Legrand' / Havells/L&T or equivalent | 3 | Each | 1,650 ₹4,950 Lowest | 1,800 ₹5,400 | 1,653 ₹4,959 |
| 2.30 | 6 way double door Make: 'Legrand' / Havells/L&T or equivalent | 1 | Each | 145 ₹145 Lowest | 1,600 ₹1,600 | 1,056 ₹1,056 |
| 3.00 | Supplying and fixing following rating 2 pole, 40 Amps Isolator in the existing MCB DB complete with connections, testing and commissioning etc as required including cost of all materials, minor tools labour charges, LWC, GST etc., complete. Isolator 2 Pole/ 230 V, 40 Amps, Make: Legrand' / Havells/L&T or equivalent | 6 | Each | 325 ₹1,950 Lowest | 900 ₹5,400 | 557 ₹3,342 |
| 4.00 | Supplying and fixing one number 5 Amps to 32 Amps rating,240/415 volts,10 KA,"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc, as required including cost of all materials, minor tools labour charges, LWC, GST etc., complete. MCB, SP, 6 - 32 Amps Make: 'Legrand' / Havells/L&T or equivalent | 42 | Each | 150 ₹6,300 Lowest | 200 ₹8,400 | 167 ₹7,014 |
| 5.00Supplying and laying of following sizes of XLPE insulated PVC inner sheathed armoured aluminium power cable of 650/1100 under ground cable conforming to 1554/7098 through DWC 63mm pipe & coupling of suitable size by excavation of earth making cable trench/ breaking of lean concrete, refilling of cable trench with excavated soil including cost of UG cable, all materials including GST & all taxes, cost of all materials and labour charges, LWC, etc, complete.) 3½ core x 50 Sqmm cable Make;' Polycap/Finolex/Havells or equivalent | ||||||
Tender Value
₹7.4 L
EMD Value
₹14,834
Closing Date
24 Nov 2025, 3:00 pmClosed
Executiving Engineer (CSWD), ALHW
Executive Engineer (CSWD), Andaman Lakshadweep Harbour Works, Sri Vijaya Puram - 744101
Providing Sub-main wiring for connection of Solar panel inverter output power to desired load for ALHW Guest House at Anarkali and Multipurpose Hall at ALHW Multipurpose Cell Complex in Sri Vijaya Puram.
2025_ALHW_885655_1
ALHW/DCEM/TECH(T134)/1/2025
Open Tender
Electrical Works
Works
30 days
ALHW Guest House and Multipurpose Hall in SVP
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹14,834
27 Nov 2025
14 Nov 2025
25 Nov 2025
14 Nov 2025
24 Nov 2025
14 Nov 2025
Amount
Wiring for circuit / sub main wiring along with earthwire with the following size of FR PVC insulated multistrand copper conductor cable in surface / recessed PVC conduit as required. (CPWD - 1.14.3)
2 x 6 sqmm along with earth wire 1 x 6 sqmm.
2 x 2.5 sqmm along with earth wire 1 x 2.5 sqmm.
Supplying and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, inter connections, phosphatised and powder painted including earthing etc.as required (but without MCB/RCCB/Isolator) etc. as required. 12 way double door Make: Legrand' / Havells/L&T or equivalent
12 way double door Make: 'Legrand' / Havells/L&T or equivalent
8 way double door Make: 'Legrand' / Havells/L&T or equivalent
6 way double door Make: 'Legrand' / Havells/L&T or equivalent
Supplying and fixing following rating 2 pole, 40 Amps Isolator in the existing MCB DB complete with connections, testing and commissioning etc as required including cost of all materials, minor tools labour charges, LWC, GST etc., complete. Isolator 2 Pole/ 230 V, 40 Amps, Make: Legrand' / Havells/L&T or equivalent
Supplying and fixing one number 5 Amps to 32 Amps rating,240/415 volts,10 KA,"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc, as required including cost of all materials, minor tools labour charges, LWC, GST etc., complete. MCB, SP, 6 - 32 Amps Make: 'Legrand' / Havells/L&T or equivalent
Supplying and laying of following sizes of XLPE insulated PVC inner sheathed armoured aluminium power cable of 650/1100 under ground cable conforming to 1554/7098 through DWC 63mm pipe & coupling of suitable size by excavation of earth making cable trench/ breaking of lean concrete, refilling of cable trench with excavated soil including cost of UG cable, all materials including GST & all taxes, cost of all materials and labour charges, LWC, etc, complete.) 3½ core x 50 Sqmm cable Make;' Polycap/Finolex/Havells or equivalent
3½ core x 50 Sqmm cable Make;' Polycap/Finolex/Havells or equivallent
3½ core x 35 Sqmm cable Polycap/Finolex/Havells or equivallent
Cable laying upto 400 sq.mm in PCC/RCC/Bitumen/Other hard surface(10.1.4 - CPWD 2025 E&M)Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 400 sq.mm in PCC/RCC/Bitumen/Other hard surface including breaking the concrete and other hard pavement and refilling the trench with PCC/RCC (20 X 30 Cm) etc. as required including cost of GI Pipe 4", breaking & concreting charges, Cement , all other materials, labour charges, GST, Minor tools etc.complete.(For Laying 50 Sqmm 3½ core cable)
Supplying and fixing 100 Amps copper Kit-Kat Rewirable Fuse carrier unit in existing lamp post making connections,etc. as required including cost of all materials, labour charges minor tools, cost of GST charges etc,.complete. Of reputed make (SELVY/GOLDMEDAL/SENTINEL or equivalent)
M/s Sai Electrical Works (BID ID -3320564)
S SAMATHNAM (BID ID -3321147)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 21.86 MB
BOQ_930927.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .