Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | ₹37.9 L Quoted ₹40.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹41.4 LRejected-Finance | ₹41.4 L | L2 | Rejected-Finance Not lowest Bidder |
| 3 | L3₹41.7 LRejected-Finance | ₹41.7 L | L3 | Rejected-Finance Not lowest Bidder |
| 4 | L4₹41.8 LRejected-Finance | ₹41.8 L | L4 | Rejected-Finance Not lowest Bidder |
| 5 | L5₹42.5 LRejected-Finance | ₹42.5 L | L5 | Rejected-Finance Not lowest Bidder |
| Sl No | Description | Qty | Unit | M/s Bansi Lal L7 | M/S Yashpaul Gulati L1 | M/s Surjit Singh and bros L4 | JAWAHAR CONSTRUCTION COMPANY L5 | manoj and company L3 | VRTRADERS L2 | RAKESH KUMAR SATISH KUMAR L6 | HAPPY ELECTRICALS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Racking out joints/ pointing to brick work or brick tiles, laid flat in floors, surface channels, roofs etc. work built in cement mortar & M&L flush pointing to brick laid flat or brick tiles in roofs and paving in cement mortar (1:3) complete all as specified and directed | 26.5 | Per 10 Sqm | 107 ₹2,835.50 | 100 ₹2,650 | 105 ₹2,782.50 | 103 ₹2,729.50 | 107 ₹2,835.50 | 102 ₹2,703 | 109 ₹2,888.50 | 105 ₹2,782.50 |
| 2.00 | Dismantling of brick tiles or terracing tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified and directed | 500 | Sqm | 41 ₹20,500 | 40 ₹20,000 | 40 ₹20,000 | 40 ₹20,000 | 39 ₹19,500 | 41 ₹20,500 | 40 ₹20,000 | 41 ₹20,500 |
| 3.00 | Dismantling brick tiles laid in double layer jointed & pointed in cement mortar incl removal of grass vegetation complete all as specified. | 530 | Sqm | 112 ₹59,360 | 112 ₹59,360 | 110 ₹58,300 | 120 ₹63,600 | 117 ₹62,010 | 114 ₹60,420 | 120 ₹63,600 | 123 ₹65,190 |
| 4.00 | Demolition mud in roofs, any thickness, including plastering and leeping etc complete all as specified and directed | 113.3 | Cum | 369 ₹41,807.70 | 350 ₹39,655 | 361 ₹40,901.30 | 358 ₹40,561.40 | 365 ₹41,354.50 | 358 ₹40,561.40 | 373 ₹42,260.90 | 366 ₹41,467.80 |
| 5.00 | Roughening surfaces of old concrete floor/ roof for removing old bitumen coat/ any other type of treatment etc., by picking, sweeping clean and washing down with water to remove dirt/ dust etc complete all as specified and directed. | 500 | Sqm | 25 ₹12,500 | 25 ₹12,500 | 24 ₹12,000 | 24 ₹12,000 | 25 ₹12,500 | 26 ₹13,000 | 26 ₹13,000 | 25 ₹12,500 |
| 6.00 | Dismantling wrought iron or mild steel work of any description as directed by Engineer In Charge | 45.36 | Qtl | 663 ₹30,073.68 | 600 ₹27,216 | 649 ₹29,438.64 | 697 ₹31,615.92 | 663 ₹30,073.68 | 613 ₹27,805.68 | 677 ₹30,708.72 | 712 ₹32,296.32 |
| 7.00 | M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, rivetting, etc., n exc 10 kg each brackets, conforming to FE 410-0 or FE 310-0 (Brackets over 10 kg each to be measured under `Structural Steel'), complete all as specified and directed. | 7,560 | Kg | 116 ₹8.8 L | 110 ₹8.3 L | 114 ₹8.6 L | 112 ₹8.5 L | 107 ₹8.1 L | 112 ₹8.5 L | 109 ₹8.2 L | 114 ₹8.6 L |
| 8.00 | M&L for water proofing treatment to sunken/roof surface including parapet wall comprising with the following course of treatment/ specifications form bottom to top:-
(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed.
(b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface
by forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.
Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.
(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. | 500 | Sqm | 496 ₹2.5 L | 495 ₹2.5 L | 485 ₹2.4 L | 509 ₹2.5 L | 514 ₹2.6 L | 506 ₹2.5 L | 525 ₹2.6 L | 520 ₹2.6 L |
| 9.00 | M&L for two coat of aluminium paint over APP membrane complete all as specified and directed. | 500 | Sqm | 76 ₹38,000 | 70 ₹35,000 | 74 ₹37,000 | 73 ₹36,500 | 76 ₹38,000 | 72 ₹36,000 | 78 ₹39,000 | 75 ₹37,500 |
| 10.00 | M&L for polythene film, 150 micron thick, laid on roofs with 150 mm overlaps complete all as specified and as directed. | 530 | Sqm | 67 ₹35,510 | 65 ₹34,450 | 66 ₹34,980 | 66 ₹34,980 | 64 ₹33,920 | 66 ₹34,980 | 65 ₹34,450 | 67 ₹35,510 |
Tender Value
₹39.0 L
EMD Value
₹77,980
Closing Date
9 Mar 2026, 6:00 pmClosed
GE (East) Ferozepur cantt
GE (East) Ferozepur cantt
Spl repair to Bldg of MES installation under GE (East) Ferozepur Cantt
2026_MES_752963_1
8181/GE/E/FZR/2025-26/E8
Open Tender
Civil Works
180 days
GE (East) Ferozepur cantt
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (East) Ferozepur cantt
₹77,980
Yes
27 Mar 2026
16 Feb 2026
16 Mar 2026
16 Feb 2026
9 Mar 2026
2 Mar 2026
Racking out joints/ pointing to brick work or brick tiles, laid flat in floors, surface channels, roofs etc. work built in cement mortar & M&L flush pointing to brick laid flat or brick tiles in roofs and paving in cement mortar (1:3) complete all as specified and directed
Dismantling of brick tiles or terracing tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified and directed
Dismantling brick tiles laid in double layer jointed & pointed in cement mortar incl removal of grass vegetation complete all as specified.
Demolition mud in roofs, any thickness, including plastering and leeping etc complete all as specified and directed
Roughening surfaces of old concrete floor/ roof for removing old bitumen coat/ any other type of treatment etc., by picking, sweeping clean and washing down with water to remove dirt/ dust etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description as directed by Engineer In Charge
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, rivetting, etc., n exc 10 kg each brackets, conforming to FE 410-0 or FE 310-0 (Brackets over 10 kg each to be measured under `Structural Steel'), complete all as specified and directed.
M&L for water proofing treatment to sunken/roof surface including parapet wall comprising with the following course of treatment/ specifications form bottom to top:- (a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing. Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions. (ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions.
M&L for two coat of aluminium paint over APP membrane complete all as specified and directed.
M&L for polythene film, 150 micron thick, laid on roofs with 150 mm overlaps complete all as specified and as directed.
M&L 80 mm thick average consolidated thickness mud phuska on flat roofs including 25 mm thick mud plaster and 3 mm thick leeping plaster etc complete all as specified and directed
M&L 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement, on mud phuska complete all as specified and directed
All as per srl item No 12 here-in-before but using old brick tiles retrieved from dismantling (item No 2 & 3 above here-in-before) including cleaning and removal of mortar from tiles complete all as specified and directed
Demolition of un-reinforced cement concrete in any position complete all as specified and directed.
M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in haunching, kerb in roof, sunken etc or similar work complete all as specified & directed.
M&L for Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof padding complete all as specified and directed.
M&L for rendering/screeding 10 mm thick cement plaster on roof, wall surfaces in cement mortar (1:4) finished even and fair and using with water proofing compound complete all as specified and directed
Supply only integral water proofing compound complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc, complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) including all quoins,arches,pillars etc,complete all as specified and directed
All as per item 20 above here-in-before but using old bricks retrieved from dismantling under here-in-before including cleaning and removal of mortar from old bricks etc including all quoins,arches,pillars etc complete all as specified and directed
Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished fair and even including WPC, preparation of new plastered or unplastered surfaces and applying two coats of cement based paint over a coat of chalk white primer on walls complete all as specified and directed. (WPC measured and paid separately)
M&L for rendering 15 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished fair and smooth without using extra cement complete all as specified including Preparation of new surfaces of wall and applying two coats of white wash on walls including corneces, pillars etc complete all as specified & directed.
M&L for rendering 5 mm thick on ceiling surfaces in cement mortar (1:3) finished even & smooth without using extra cement including preparation of new plastered or unplastered surfaces and applying two coats of white wash on ceilings complete all as specified and directed.
M&L for Preparing old surfaces plastered or unplastered of ceiling, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime wash (white washing) complete all as specified and directed.
M&L for Preparing old surfaces plastered or unplastered of walls, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coats of cement based paint complete all as specified and directed.
M&L for Preparing old surfaces plastered or unplastered of walls, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime wash (white washing) complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and directed.
All as per item No. 29 above herein before but size exceeding 1.5 Square metre and not exceeding 4 Square metre each, complete all as specified and directed.
S&F for Pressed Steel Frames for doors 1.25 mm thick MS sheet of profile (105X60)mm for doors and windows frames with one or more rebates including necessary fixing lugs, hinges, lock, strike plates, shock absorber 20mm dia, 60mm MS conduit for housing of a drop bolt etc. treating of internal surfaces of chowkhats with coal tar or black paint complete all as specified and directed
S&F 35mm thick, Flush shutters, solid core construction, with block board core, commercial type with one face is covered with deco rative face veneer with lipping/frame to match complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20 mm graded stone agg .as in filling steel frames etc including necessary form work complete all as specified and directed
Material and labour for PCC (1:2:4) type B1 with using 20 mm graded stone agg as in bed block hold fast block complete all as specified and directed
S&F Aluminium tower bolt of extruded section, 150mm length of bolt and fixed with screws, complete all as specified and directed.
S&F 125mm size, aluminium (cast type) anodized, handle and fixed with screws complete all as specified and directed.
S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy and fixed with screws complete all as specified and directed.
S&F factory made double rebate box type side hung steel window with glazed and mesh shutters with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle with & without glazing bars, one side two shutters with glazing bars & other side glazed shutter with glazing bars including 10mm mild steel guard bars dovetailed or welded and with framed with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07. Note Wiremesh & glass will be measured separtely.
S&Fstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture not more than 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed
M&L for Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over steel surfaces complete all as specified and directed.
M&L for preparation of new steel and iron surfaces not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Preparation of old decorated surface of steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Preparation of old painted wood or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified and directed.
Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed
Taking up or down existing steel water tubing, 20mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed
S&F Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Fixing only, after cleaning old steel water tubing, 15mm bore and connections in new or old position using new fittings complete all as specified and directed.
Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings complete all as specified and directed.
Taking down eaves gutters and rainwater pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends/shoe any radius with access door fixed to walls including distance pieces and stack clamps complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile trength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of Stone slabs and tiles laid bedded pointed in mortar of any description or thickness in floors, aprons etc, complete all as specified and directed.
M & L Machine cut kota stone slab flooring 18-20mm thick over 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified
S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specified for following : (a) One light/fan/bell/Bldg security light point controlled by one single pole one way switch.
All as per item No. 61 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board, complete all as specified and directed.
All as per item No. 61 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on same board, complete all as specified and directed.
All as per item No. 61 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed.
S&F 6 amps, single pole, one way switch urea back piece (IP20), 240V, 50Hz, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F Switch piano flush type 16 amps, single pole one way, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F 6 Amps Socket 2 in 1, Urea backpiece (IP20), white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F Socket outlet, UNI, 2 in one 10 Amps & 20 Amps, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F batten holder, 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
S&F rotary stepped type electronic fan regulator compatible for BLDC for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, deluxe, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza.
Fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core FR PVC Insulated & overall round sheathed flexible with PVC, colour of cores are Red, Black & Yellow/ Green is for earthing. Sheath colour is Black of cable size 23/0.0076 complete all as specified and directed. Note : Ceiling fans obtained/ taking down from item Sr No. 58 as above
Supply and fixing LED light fitting 1 x 20 Watt, 220V, AC decorative with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S&F LED bulb of 9/10 watts B-22 CDL 3 star 6500K, complete all as specified and directed.
S&F LED street light fitting toughened glass 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp incl suitable size MS/ GI bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed.
S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, partly immersed in wall, including of MCCB 4 pole adjustable thermal & fixed magnetic type 100 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning, complete all as specified and directed.
S&F MCB SP, 32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning, complete all as specified and directed.
M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length).
S&F exhaust fan heavy duty copper winding with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
Cutting holes making good the distributed surface, grouting nuts for fixing of Exhaust fans complete all as specified and directed.
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to sxposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
CA8181.pdf
Tender Documents • 1.31 MB
BOQ_843356.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid