Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-Finance R O DR AMBEDKAR NAGAR SANGRUR | SANGRUR | SANGRUR | PUNJAB | ₹16.3 L | L1 | Accepted-Finance L1 |
| 2 | L2₹17.3 LAccepted-Finance | ₹17.3 L | L2 | Accepted-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
Tender Value
₹19.6 L
EMD Value
₹39,500
Closing Date
3 Mar 2026, 1:00 pmClosed
Executive Engineer, Construction Divn PWD Patiala
O/o Executive Engineer, Construction Division, PWD B and R Patiala
New Construction of NCC/NSS Block at Govt. Kirti College Nial, Patran, District Patiala
2026_CEPW_160599_1
Bid no. 35 dated 16.02.2026
Open Tender
Civil Works - Buildings
45 days
District Patiala
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹39,500
Yes
6 Apr 2026
18 Feb 2026
3 Mar 2026
18 Feb 2026
3 Mar 2026
18 Feb 2026
Civil work
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS- 6313- 2001(Part 2)& using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundationpits, by treating the bottom& sides upto height of 300mm by uniformly spraying solution @ 5Litre/Sqm(ii) In there fill earth on both sides of all built up walls@ 7.5Litre/Running meter (width-300mm,depth- 450mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outerperimeter @5 Litre solution per Sqm.
Cement Concrete 1:5:10 with stone ballast using mechanical mixer volumetric type.
Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth.
Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in Superstructure.
Door Lintel
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Damp proof course 2.5 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Ground Floor
First Floor
Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block / Clay Block.
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
12.5 mm thick cement plaster 1:4.
20mm thick cement plaster 1:4 in two coat work.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating (P.T.M.T.)
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc.
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead .
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40%excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100 mm thick cement concrete1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Bearing plaster of 10 mm thick cement plaster 1:3 cement sand finished with a floating coat of neat cement and thick coat of lime wash/POP on top of walls when dry for bearing of RCC slabs and beams.
Extra labour for projected nosing of staircase of any shape and design.
Providing and laying vitrified floor tiles in different size in light colour shades made using Full Body Technology (thickness to specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ), complete. (Full body vitirified tiles have pigment in entire body/ thickness of which make chips and scratches less noticeable and na ideal choice for high traffic zones) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout )with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size 600x600 mm.
Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. (Single Rebate ) Doors and windows frame of size 118mm x 60 mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. (Double rebate )Doors and windows frame of size 151 mm x 60 mm with 35 mm wide double rebate weighing 3.95 kg per meter.
supply and fixing of window shutter consisting frame fabricated from sheet roll formed out of .58mm thick galvanised sheet(base steel as per is:513 ) with zinc of 120gm/sqn steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD .58mm of approved shade , fixed in position fixed in position by means od screw , complete in all respect as per drawing , design , specification & entire satisfection of engineer-in-charge glazed window shutter section 47mm x 20mm (without glass)
wire mesh window shutter section 40mm * 20mm with s.s wire mesh 32 gauge flymesh with 144 holes per square inch
providing and fixing glazing in door, window , ventilator shutters and partition etc complete as per the architectural dwg and direction of engg-in-charge (cost of gasket / beading shall be paid as per respective item ) float glass panes of 5mm thick
providing & fixing beeding size 12mm x 12mm for fixed glass with ECO fixed gasket(EPDM)
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 30mm Thick
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing & Fixing door closer 700-800 mm of approved make as desired by Engineer-in-Charge I.S.I DesignationNo. II (size of door 701mm to 850mm)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and applying plaster of paris (ISI marked such as JK,Kohinoor,Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Distempering with Acrylicw washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to givean even shade
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work,metallic or plastered,concrete surface to give an even shade.
Finishing walls with acrylic smooth exterior paint of required shade witht woor more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Construction of Plinth protection complete as per drawing.
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer volumetric type.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling
Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
ELECTRICAL WORKS
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 25sq.mm (3½ Core) Un- armoured (On-Surface)
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring 16/20Amp. power plug control point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 6Amp. wall socket point
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve- C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each
SHEET METAL IRON CLAD SWITCHES:
Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-
ICTPN Switch 63amp., 415volts
OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS:
Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminium link clips complete in all respect as approved and desired by the Engineer In Charge at site.
PVC insulated & PVC sheathed aluminium conductor cable Overall Size 10mm² (1/1.40mm) Twin Core
M.S. JUNCTION BOX FOR STREET LIGHT:
Supply and erection of M.S. Junction box of suitable size made from M.S. Sheet 16 SWG (1.60mm thick). Junction box should have one locking arrangement and 2 nos. hinges on front side. It should have 1 No. Brass terminal connecting strip, 1 No. Kit kat 16 Amp/240 Volts along with M.S. Flat 20mm x 2mm clamp with nuts and bolts for fixing on the pole. The junction box should be painted with one coat of good quality primer and two coats of post office red enamel paint inside and outside complete in all respect:-
M.S. Junction Box 205mm x 155mm x 95mm
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Ceiling Fans 1200 mm Sweep (48") 3-Star having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply and erection of Heavy duty Exhust Fans 450mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of LED Flood Light 50watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK 07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.09 MB
sbd.pdf
Tender Documents • 6.46 MB
BOQ_325992.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid