Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC CHOMO JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹43.5 L+₹7.3 L (20.0%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹48.4 L+₹12.2 L (33.5%)Rejected-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹86,980
Closing Date
21 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Air Force
Military Engineer Services AF Stn Adampur 144103
ADDITION/ALTERATION TO 13 AND 31 END ORR AT AF STN ADAMPUR
2024_MES_674382_1
GE/AF/ADM/T-32/2024-25
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹86,980
Yes
29 Nov 2024
13 Sept 2024
22 Oct 2024
13 Sept 2024
21 Oct 2024
25 Sept 2024
14 Sept 2024 - 24 Sept 2024
Amount
B/R Works
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete all as specified and directed.
Rough excavation n.exc (not exceeding) 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, laying under ground cables, foundation of poles etc. and getting out complete all as specified and directed .
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete all as specified and directed.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Broken stone hardcore of gauge n exc. 63 mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed .
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates in surface channels and drains complete all as specified and directed .
PCC type B-2 (1:2:4), using 40 mm graded stone aggregates in sub flooing/ mass concreting complete all as specified and directed .
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
Cement concrete, type B-1 (1:2:4), using 12.5 mm graded crushed stone aggregates as in lintels up to 1.5 metre clear span, bed blocks of holdfast, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified and directed.
Precast RCC type B-1 (1:2:4), using 20 mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4) complete all as specified and directed.
Reinforced cement concrete type B-1 (1:2:4), using 20 mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified and directed.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain printed PVC Sheet & 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mmx10mm (90 Degree)used instead of exposed portion of PVC sheet beading & PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and a gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site all as specified in SSR part-II & part-I complete all as specified and directed.
Solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing on PVC frame complete all as specified and directed.
5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame, complete all as specified and directed.
Factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified and directed.
Factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws,etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed. NOTE: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.
NOTES APPLICABLE TO SERIAL ITEM 22: - (i) After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality. (ii) Glass or wiremesh shall be paid separately) (iii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long, complete all as specified and directed.
Stainless steel sliding door bolt with hasp and staple (bolt type) and fixing round typeclips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long complete all as specified and directed. MAKE: PRAYAG CAT NO. SLD-1210 or equivalent make mentioned in Appndix 'B'
04 levers brass mortice lock, vertical type, 100 mm size, with 2-3 keys, IN REPAIRS, complete all as specified and directed.
Double action floor door spring, hydraulically regulated, made of 1.25 mm thick aluminium alloy sheet, foundation box main body with stainless steel cover, governing pivot made of brass, rest of part made out of heavy duty mild steel, ISI marked, complete.
Aluminium (Die cast) door closer hydraulically regulated designation No. 2 aluminium body universal type suitable for door shutters of 701 to 1100mm in width and weight between 61 to 80 kg, ISI marked, IN REPAIRS, complete all as specified and directed
Aluminium anodised barrel tower bolt of extruded section 150 mm long, ISI marked, complete all as specified and directed.
Aluminium anodised barrel tower bolt of extruded section 200 mm long, ISI marked, complete all as specified and directed.
Extruded aluminium anodised handles 125 mm long fabricated type with plate , ISI marked complete all as specified and directed.
Powder coated (Coloued) Mild steel conduit 20 mm bore, cut to size and erected in position as curtain rod on backets, with & including matching decorative finials & brackets, PVC rings @ 10 nos. per metre, fixed to walls with PVC rawl plugs & SS screws, IN REPAIRS, complete all as specified and directed.
Double leg aluminium anodised door stopper 100mm long with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, IN REPAIRS, complete all as specified and directed.
Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified and directed.
Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, quality confirming to grade Fe-290-Gde E-165, complete all as specified and directed.
Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.
Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Cast iron work grade FG 150, unmachined in bracket, gully traps, gratings, railings, frame manhole cover, fire and shoot door, dampers, stop valves boxes and similar articles complete all as specified and directed.
Mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) quality confirming to grade Fe-290-Gde E-165, complete all as specified and directed.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Powder coated aluminium door shutters with styles & rails made out of section size 83-85 mm x 44-45 mm (wall thickness not less than 2 mm) , anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified and directed. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated aluminium window and ventilator shutters side hung type with styles & rails made out of section size 47-48 mm x 44-45 mm (wall thickness not less than 1.58 mm), anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified and directed and directed. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated GI snap grid frame work including suspenders with size of grid 605 mm x 605 mm for false ceiling all as specified and shown on serial page No. 186 of MES Schedule Part-II complete all as specified and directed.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs / trusses by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
12mm thick Gypsum Board; multipurpose, decorative type for false ceiling, including straighting of frame if any required all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including taking down existing sheet complete all as specified and directed.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified and directed and directed.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed.
100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed.
Water Proofing Treatment to RCC roofs comprising of : -
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified and directed.
PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified and directed.
Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified and directed. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over cleaned RCC/plastered roof surfaces & flashings complete, all as specified and directed.
40 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4), and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified and directed.
Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE, complete all as specified and directed. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
NOTE : For Guarantee of Water Proofing Treatment refer PS clause 11.5.
Supply only water proofing compound, ISI marked, complete all as specified and directed.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified and directed.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified and directed.
Glazed ceramic coloured tiles not less than 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed.
First quality, vitrified ceramic, double charged tiles 9-10mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed.
First quality, vitrified ceramic, double charged tiles 9-10mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed.
Endura vitrified paving coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but not exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified and directed.
80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50 mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
Supply and Laying 400 micron HDPE polythene film including all necessary cutting & overlapping after applying evenly a tack coat of industrial bitumen VG-10 @ 2.5 kg per sq. m complete all as specified and directed.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6), complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair as , in cement mortar (1:4), complete all as specified and directed.
Three coats of white wash on new plastered ceiling surfaces, including preparation of surfaces, complete all as specified and directed.
One coat of interior acrylic distemper of old ceiling surfaces including prepration of surfaces complete all as specified and directed and directed.
One coat of interior acrylic distemper (white / tinted) of old wall surfaces including prepration of surfaces complete all as specified and directed.
Prepration of new plasterd wall surfaces of any description complete all as specified and directed and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer.
Two coats of exterior acrylic emulsion in disruptive/camouflaging pattern of six/four shades over and including a coat of exterior (water based) primer on PQC surfaces of any descripton, taxi tracks, links, shelter/ runway surfaces and the like horizontal surfaces, disruptive/camouflaging pattern of Six/four shades with mechanical sander having RPM of min 1200 having suction vaccum bag complete all as specified and directed and directed
Prepration of new wall surfaces of any description in disruptive/camouflaging pattern of Six/four shades complete all as specified and directed and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
NOTES APPLICABLE TO SERIAL ITEM NO. 66 TO 71: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer's Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii) The work shall be got executed through paint manufacturer/ authorised applicators of manufacturer's as specified in relevent PS clause.
Sheet glass 5-6 mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5sqm in each pane complete all as specified and directed.
Sheet glass 5-6 mm thick ordinary quality and glazing with oil putty or wooden beads in squares exc. 0.5sqm in each pane complete all as specified and directed.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
Peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc 30 cm thick, watering, ramming to obtain optimum moisture condition to the specified percentage of standard proctor density not less than 95 percent and finishing to required size & shape as directed by Engineer-in-Charge for height : -
Not exceeding 1.5 metre high from base
Exceeding 1.5 metre but not exceeding 3 metre high from base
NOTES FOR SERIAL ITEM NO 77 : - (i) Quoted rates shall include the cost of earth / soil to be brought from out side MoD land. (ii) Removing boulders / lumps of size 75mm and above by screening the soil before filling in traverse.
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking up or down steel tubing and connections from existing location, complete all as specified and directed of size: -
15mm bore
20mm bore
1000 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified and directed including the following acessories: - (i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified and directed. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified and directed. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, IN REPAIRS, complete all as specified and directed.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed MAKE:PRAYAG Cat No. P-6510 or equivalent make mentioned in Appndix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE:PRAYAG Cat No. P-6518 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE:PRAYAG Cat No. P-6508 or equivalent make mentioned in Appndix 'B'.
Pillar tap, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE: KEROVIT Cat No.KB1211001 or equivalent make mentioned in Appendix 'B'.
Wall mixer, cast copper alloy chromium plated, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS complete all as specified and directed. MAKE: KEROVIT Cat No. KB511021 or equivalent make mentioned in Appendix 'B'.'.
Overhead ABS 125mm shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix 'B'.
Sheet glass shelf 500x125 mm with brass chromium plated bracket guard and railing, IN REPAIRS complete all as specified and directed. MAKE: PRAYAG Cat No. BEA-45 or equivalent make mentioned in Appndix 'B'.
Corner glass shelf 300 mm size with brass brackets fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. BEA-44 or equivalent make mentioned in Appndix 'B'.
Brass chromium plated towel rail 500 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix 'B'.
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including Health faust with 1 metre SS tube & hook, soft close ISI marked PVC seat & cover, IN REPAIRS, complete all as specified and directed MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix 'B'.
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 504 or equivalent make mentioned in Appndix 'B'
Vitreous China wash hand basin, white, IS marked of size 550 x 400 mm, fixed IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appndix 'B'
Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints, IN REPAIRS complete all as specified and directed.
Stainless steel round slotted grating with frame, 125 mm size fixed in position with cement joints, IN REPAIRS complete all as specified and directed.
PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS, complete all as specified and directed.
Stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 940mm x 460mm x 203mm with bowl size 405mm x 354mm x 203mm IN REPLACEMENT complete all as specified and directed MAKE: PRAYAG Cat No. P-1342D or equivalent make mentioned in Appndix 'B'.
Rolling and consolidating formation surfaces with power roller exc 8 tonne and n. exc. 12 tonne complete all as specified and directed.
Rolling and consolidating soiling surfaces with power roller exc 8 tonne and n. exc. 12 tonne complete all as specified and directed.
uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / wall as SWR pipes, IN REPAIRS, complete all as specified and directed of size: -
75 mm external dia pipe
110 mm external dia pipe
uPVC/PVC bend any radius, complete all as specified and directed. suitable for uPVC soil waste discharge pipes, IN REPAIRS, of size: -
75 mm external dia pipe
110 mm external dia pipe
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified and directed,
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified and directed.
Concrete bed to drain pipes 300 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified and directed.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified and directed.
Reinforced concrete pipes 300 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified and directed.
Construction of "SOAK WELL" of size 3.60 m dia & 3 metre effective depth complete all as specified and directed and shown on drawing No. CEJZ/STD-301/90 sheet 1/4 to 4/4.
INTERNAL ELECTRIFICATION WORKS
Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES FOR SERIAL ITEM NO 109: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified and directed.
Switch piano flush button single pole one way, 16 Amp complete all as specified and directed.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified and directed.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, step socket type, single phase, complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified and directed for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified and directed.
Sand cushioning ( local dry river sand) for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed. NOTE:- Punned down thickness (over all 18cm) shall be considered for measurement and payment.)
Brick protection with pulverized fuel ash lime bricks laid flat across the route of underground cable all as specified and directed.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified and directed comprising the following: -
SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
VTPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified and directed.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, complete all as specified and directed.
Blanking plate to cover unused space in DB's complete all as specified and directed..
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified and directed.
Envirnment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, IN REPLACEMENT, complete all as specified. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete all as specified and directed. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 10W lighting fixture 2 feet long, 6500K, lumen output should not be less than 90 lumens per watt, including making connections, complete all as specified and directed. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly with eye soft technology & glarefree diffuser LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete all as specified and directed. MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
LED flood light 80 watt , outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W IP 66 protection IN REPLACEMENT and making connections, complete all as specified and directed. MAKE: Wipro Cat part no. LF40-102-060-57-XX or equivalent make mentioned in Appendix 'B'.
Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, plastic body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified and directed. MAKE: Havells Cat No. FHVVEDXWHT10 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Electric water heater storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litre, BEE 5 star rating complete with all accessories such as safety valve, thermostate, NRV, steel PVC connector for hot water etc complete all as specified and directed. MAKE: Havells Cat No. GHWAFATWB025 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable complete all as specified and directed, of following description: -
10 Sq.mm, 2 core
50 Sq.mm, 3.5 core
NOTE:- Excavation and earth work, brick protection and sand cushning will be measured & paid separatly under respective item of BoQ)
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq.mm GI wire earthing lead complete all as shown in electrical plate No. 3 and as specified in Particular Specifications clause 19.1.1 of contract, IN REPLACEMENT complete all as specified and directed.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 25 mm x 4 mm GI strip earthing lead complete all as shown in electrical plate No. 3 and as specified in Particular Specifications clause 19.1.1 of contract, IN REPLACEMENT.complete all as specified and directed
Earthing with and including copper earth plate electrode 3.15 mm thick of size 600 mm x 600 mm with 20 mm x 3 mm copper earthing strip complete all as shown in electrical plate No. 3 and as specified in Particular Specifications clause 19.1.2 of contract, IN REPLACEMENT. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit. (c) Earth resstance shall be less than 2 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed, IN REPLACEMENT, with & including the following: -
Copper strip of size 20mm x3mm.
GI strip of size 25mm x4mm.
Aluminium strip of size 25mm x3.15mm.
NOTES: (a) Strips to be fixed with porcelain/polymer insulators at the intervals of 0.6 metre so as not to be in electrical contact with building structure. (b) Brazing shall be done on both sides (overlapping) at all joints except test point.
Earth continuty conductor galvanised iron main earth lead of size 4 sq. mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles/DBs or any other directed location, IN REPLACEMENT, complete all as specified and directed.
Air termination, single pointed aluminium rod 12 mm dia 300 mm long IN REPLACEMENT, complete all as specified and directed.
Medium grade GI tubes size 40mm bore , with necessary GI fittings laid in floors / wall complete all as specified and directed, IN REPLACEMENT, complete all as specified and directed and directed.
Taking down carefully industrial type call bell and indication/ navigation light fitting, refixing and testing the same after completion of internal work as its original position, complete all as specified and directed.
Disconnecting & taking up exhaust fan of any type and any capacity or description and refixing & reconnecting the same on same or new location with & including provision of fasterners, complete all as specified and directed.
EXTERNAL WATER SUPPLY WORKS
Mild steel ERW pipe fixed with header, non return valves, slucie valvesetc. laid on pillars,/ iron stage as per the requirement having wall thickness not less than 8mm, ISI marked (IS-4270), including necessary fittings and jointing duly painted with a coat of bituminous paint on external surface of pipe, complete of size: -
65 mm bore,
100 mm bore,
Submersible pumping set non clog vertical type, with chrome steel impeller and cutter, non clog to pass 30mm size particles suitable for 65mm dia pipe , of discharge capacity 396 LPM at 20 metre head, and including 3 phase, 415 Volts, suitable capacity electric motor of the same manufacturers, including MS adopter or reducer, tail piece, flange and all accessories for proper functioning of pumping set etc including installation, testing and commissioning complete. MAKE: KSB Cat No. 3700CW or equivalent in makes mentioned in Appendix 'B' here-in-after.
PVC Insulated & PVC Sheathed submersible flat copper conductor cable 3 core of size 6 Sq.mm 3 core, suitable for working voltage 1100 Volts conforming to IS 694 including making connections to motor/starter, complete all as specfied.
DOL starter suiltable for 7.5 HP motor pump, complete all as specified and directed and directed
Cast iron Buterfly valve size 65mm dia, ISI marked (IS- 13095) heavy duty & including necessary flanged joints & jointing material, suitable for DI/CI pipe of size: -100 mm bore
Cast Iron Non return/Reflux valve 65 mm bore, flanged Type, class PN 1.6, ISI marked (IS- 14846-2000) complete with stainless steel spindle flanged both ends drilled CI gate with brass ring and iron wheel handle complete all as specified and directed with & including necessary flanged joints & jointing material, complete, all as specified.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including dismantling complete all as specified and directed and directed.
Demolition and Dismantling work
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50sqm each and removing from site all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50sqm but not exceeding 4.00sqm each and removing from site all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster of any description on brick walls, ceiling or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided all as specified.
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed and directed.
Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed
Demolition and breaking up 300mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified and directed.
Taking down carefully light fitting of any description, complete all as specified and directed.
Taking down carefully electric bell/buzzer of any description, complete all as specified and directed.
Taking down carefully service cable of any description, complete all as specified and directed.
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
siddharthenterprises (BID ID -3137693)
AAR KAY BEE ENTERPRISES (BID ID -3138306)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .