| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.7 L+₹20,524.06 (2.42%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹8.8 L+₹32,234.26 (3.80%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹9.8 L+₹1.3 L (15.5%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹11.8 L+₹3.3 L (39.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹20.1 L
EMD Value
₹40,200
Closing Date
18 Oct 2021, 6:00 pmClosed
GE (AF) Bhisiana
Military Engineer Services, Garrison Engineer (AF), Bhisiana, Bathinda-151201
Repair to Leakage, Seepage and certain B/R Nature Work in OTMs, Airmen Billets Accn in Domestic Area at AF Stn Bhisiana
2021_MES_476538_1
GE/BHI-41/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Bhisiana
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Bhisiana
₹40,200
Yes
6 Dec 2021
20 Sept 2021
20 Oct 2021
20 Sept 2021
18 Oct 2021
4 Oct 2021
21 Sept 2021 - 29 Sept 2021
Amount
Demolition of concrete above ground floor for sunken portion exc 15 cm thick and removing the rubbish out side MD land complete all as specified.
M&L for 15 mm thick rendering in cement mortar (1:4) as in sunken portion mixed with water proofing compound 3% by weight of cement, finishing surfaces even & smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound shall be measured and paid under appropriate item of this Sch ‘A’.
M&L for bitumen blown any grade, applied hot, two coats to concrete surfaces at the rate of 1.5 Kg per Sqm per coat complete all as specified.
M&L for polythene film, black, 50 Micron laid in floors.
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in filling of sunken and mass concrete complete all as specified and as directed.
M&L for Cement concrete type, B1, 1:2:4 (20mm graded stone aggregate) 40mm thick including finishing the surfaces even and fair to receive floor finishes.
M&L for Renewing glazed tiles in patches, area n.exc 5 sq.m. including removing and leaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified.
M&L Coloured Non Skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding in 1:6 CM complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x300x7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including 10mm thick cement plaster 1:4 CM to receive vertical tiles compete all as specified and as directed.
M&L for coloured joint free vetrified tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified.
M&L for coloured joint free vettified Tiles 9 to 10mm thick (square/ rectangular) on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 to receive vertical tiles complete all as specified.
M&L coloured Non Skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding in 1:4 CM complete all as specified and directed.
M&L 20 mm bore GI tubes for providing spout pipes in lowest portion of sunken portion (Minimum length of each spout pipe 40 cm).
Dismantling brick tiles or terracing tiles single layers on roof complete all as specified and directed.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska.
M&L for relaying after proper levelling and ramming of existing mud puska of 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska.
Demolition of existing roof treatment including pad concrete, cement plaster and deteriorated membranes.
M&L for cutting out cracks to V section in existing roofs or terracing, cleaning out wetting grouting with cement and slurry 1:3.
M&L for cutting out cracks to V section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight).
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc.
Brushing neat cement slurry with 3.0 Kg of cement per sqm after cleaning of brick tile surface/concrete surface by wire brush and water.
Demolition of cement concrete in any description and in any position not otherwise specifically provided for.
M&L for providing cement concrete type B-0 (1:2:4), 12.5 mm graded stone aggregate for providing slope, roof kerbs or mud stops rounded or chamfered edges all as directed by Engr-in-Charge.
M&L for 10mm thick cement plaster in cement mortar 1:3, including finishing even and smooth without using extra cement mixed with water proofing compound, mixed as per manufacturere instructions complete all as specified. Note : Water proofing compound shall be measured and paid separately.
Supplying only liquid water proofing compound , ISI marked complete all as specified and as directed.
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a tack coat of indestrial bitumen grade 85/25 @ 1.2 Kg/Sqm at bottom of the membrane as bonding material, all as specified and directed by Engineer-in-Charge.
Removing of bushes upto 10 cm dia trunk, grass from roof top, racking out joints/pointing to brick tiles and flush pointing with 1:3 cement mortar with water proofing compound, all as specified as directed.
M&L for PCC, 1:2:4 type B1, (20 mm graded aggregate) as in repair of chajjas, suspended slab etc, including demolition with wooden hammer and necessary formwork complete all as specified as directed by Engr-In-Charge.
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles.
M&L for Brick work with subclass 'B' bricks, staright or curved on plan exc 6.00 mtr mean redius, built in 1:6 cement mortar.
Taking down cement plaster on brick or stone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for 15 mm thick plaster in 1:4 cement mortar and finishing the surface even and smooth without using extra cement including applying two coat of cement base paint over a coat of primer and after preparation of new plastered surfaces.
M&L for Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed in cluding dismantling of cracked or UNSV tanks.
M&L for rotational moulded polyethylene water storage tanks Triple Layer White Colour 1000 ltr Capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified including dismantling of cracked or UNSV tanks.
S&F Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
M&L Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store.
Refixing 15 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) using new/serviceable GI fittings.
M&L 15 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified.
M&L Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store.
Refixing 20 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.).
M&L 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including clamps, nut bolts including dismantling of old AC rain water pipe etc in repairs.
Supply and fixing 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Supply and fixing 40mm dia GI pipes as rain water spout pipes fixing in kerb or parapet walls one end cut in 45 degree angle including cutting of holes and fixed by PCC B-0 (1:2:4) and CM 1:3.
S&F 3 mm dia GI wire for mosquito string with tightening fasteners fixed to the wall by anchorage bolts and 5 mm thick MS base plate in PCC 1:2:4 or brick work including making the disturbed surface to matching with sorroundings by plastering and painting.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any gauge, thickness and in any position including Nainital or similar pattern roof coverings.
Dismantling of corrugated steel sheeting in roof coverings any gauge, thickness and in any position including Nainital or similar pattern roof coverings.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.45 mm thick of an coloure having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as directed.
Dismantling of wrought iron or mild steel work of any description not other wise provided for.
Fixing only rolled mild steel as in roof trusses (framed/unframed) purlins, rafter, trusses, rails and wind tie etc (Tee, Angle, channel or flat sections) incl distance pieces etc of grade Fe-410-W complete all as specified and as directed.
S&F rolled mild steel as in roof trusses (framed/unframed) purlins, rafter, trusses, rails and wind tie etc (Tee, Angle, channel or flat sections) incl distance pieces etc of grade Fe-410-W quality 'A' complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces.
Dismantling of Wall and ceiling boards or insulation boards/ slabs/ blankets, any thickness, including cover fillets.
S&F of anodised aluminium snap grid of size 605 x 605mm frame work for false ceiling incl 2mm dia GI wire for hangers where ever required all as specified.
M&L 4 mm thick non asbestos fibre cement building boardsin ceilings, fixed or laid/inserted to timber/GI/Aluminium frame work with screws.
GUPTA AND ENGINEERS
M/s Kamal Builders
M/s Luxmi Constructions
M/s BALDEV SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .