Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L-1 | Accepted-AOC L-1 BIDDER |
| 2 | L-2₹1.1 Cr+₹74,882.47 (0.71%)Rejected-Finance | ₹1.1 Cr+₹74,882.47 (0.71%) | L-2 | Rejected-Finance NOT L-1 BIDDER |
| 3 | L-3₹1.1 Cr+₹4.1 L (3.86%)Rejected-Finance | ₹1.1 Cr+₹4.1 L (3.86%) | L-3 | Rejected-Finance NOT L-1 BIDDER |
| 4 | L-4₹1.1 Cr+₹5.0 L (4.72%)Rejected-Finance | ₹1.1 Cr+₹5.0 L (4.72%) | L-4 | Rejected-Finance NOT L-1 BIDDER |
| 5 | L-5₹1.1 Cr+₹5.5 L (5.20%)Rejected-Finance 651 MUKHERJEE NAGAR DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹1.1 Cr+₹5.5 L (5.20%) | L-5 | Rejected-Finance NOT L-1 BIDDER |
Tender Value
Refer Docs
Closing Date
21 Jul 2021, 3:00 pmClosed
Chief Technical Services Manager
Indian Oil Corporation Ltd., Pipelines Division Bijwasan New Delhi
Renovation of Admin building at NRPL Bijwasan.
2021_NRBIJ_137559_1
PMJTS21008
Open Tender
Civil Works
Works
150 days
NRPL Bijwasan
Please refer Tender documents.
9 documents required · 9 mandatory
Exempted
25 Feb 2022
1 Jul 2021
22 Jul 2021
1 Jul 2021
21 Jul 2021
9 Jul 2021
Amount
Dismantling aluminium/ gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by the Engineer-in-Charge.
Dismantling G.I. pipes (external , Internal & concealed) after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
a) 15 mm to 40 mm nominal bore
b) Above 40 mm nominal bore
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] : Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
a) Of Area 3.0 Sq.m and below
b) Of Area beyond 3.0 Sq.m
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1.0 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
Melamine polishing on wood work (two coats).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two coats on old work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two coats on old work
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content : With water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre.
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/10 sqm) on existing cement paint surface.
ACP CLADDING WORK: Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: (A) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (B) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based fluoropolymer resin coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (C) The fastening brackets of Aluminium alloy 6005 T5/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is included in this item only. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in square metre up to two decimal places.
Diluting and injecting chemical emulsion (Chlorpyriphos/ Lindane E.C. 20% with 1% concentration) for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same :
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) (Make: Armstronge Dune Beveled Tegular 9/16 or equivalent)
Providing and fixing LUXALON 75C & 225C un-perforated Aluminium panel coloured ceiling manufactured by M/s. HUNTER DOUGLAS INDIA or any other approved equivalent brand, each panel consisting of 75/225 mm wide x 15.5 mm deep and 0.5 mm thick with bevel edged panel made from enamelled corrosion resistance aluminium alloy AA-5050 (Al.Mg), each panel to abut each other with a narrow 'V' groove, clipping with a baked enamelled aluminium panel carrier of 32 mm wide x 39 mm deep x 0.95 mm thick in standard length of 5 metres made of double baked enamelled aluminium alloy AA-5050 (Al.Mg) black with cutouts to hold the panels in a module of 75 mm closed at a distance of 1.25 metre, each panel carrier suspended by means of G.I. suspension rod 4 mm diameter and a galvanised supsension spring clip at a distance of 1.7 metre centre to centre, making openings for light fittings etc. with suitable peimeter framing all complete as per manufacturer's recommendation and directions of the Engineer-in-Charge. [Note: Measurement shall be made wall to wall without any deduction for openings, for payment purpose].
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and shade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels :
a) Area of slab up to 0.50 sqm
b) Area of slab over 0.50 sqm
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be included in this item only) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
a) Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
b) Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement, with : 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources]
Centering and shuttering including strutting, propping etc. and removal of formwork for :
a) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
b) Columns, piers, abutments, pillars, posts and struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500 D or more
Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coarse aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge : For 50 Users
Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level :
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing and paneling to be paid for separately] : For fixed portion : Powder coated aluminium (Minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade-l Type-ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. Brass/ Stainless Steel screws etc. complete as per architectural drawings and directions of the Engineer-in-Charge : Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] : With float glass panes of 5.50 mm thickness
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (both primary and secondary sealant) etc. as per specifications, drawings and directions of the Engineer-in-Charge complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and directions of the Engineer-in-Charge complete : Up to 5 mm depth and 5 mm width
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints. : Size of Tile 600x600 mm
Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing 100mm wide Vertcal Fabric Blind system of VISTA/ MAC/ TRAC of approved make & shades complete along with standard accessories in required design/ shade as per manufacturer's recommendations, specification and directions of the Engineer-in-Charge.
12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand)
Repair to plaster of thickness 12 mm to 20 mm in patches of area up to 2.5 SQM including cutting the patch in proper shape, raking out joints, preparing and plastering the wall surface etc. complete, including disposal of rubbish at unobjectionable area outside Ownder's premises, all complete as per directions of the Engineer-in-Charge : With cement mortar 1:4 (1 cement : 4 fine sand)
Providing and fixing in position built-up cupboard, internal framework, shelves, drawers, layon slides partitions and shutters 19 mm thick pre-laminated block board of BWP Grade, Decorative Type (BWP-DEC) of approved quality or equivalent stamped with IS-1659:2004 (Latest Edition) and pre-lamination should conform to IS-2046:1995 (Latest Edition) and 3 mm thick teak wood lipping at all edges of the board with polish/ enamel paint fixed with water resistant adhesive on inside and external face as per approved shade including piano type hinges 19x25 mm, best quality teak wood lipping around the shutter edges, magnetic ball catchers, brass tower bolt, knobs, handles with S.S. roses 150 mm x 19 mm diameter (Ref. Make - DORSET, Model - IP 06 PR SS or approved equivalent) complete as per drawing including spirit polishing/ enamel painted on lipping in required shade matching to the laminate etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge. (Measurement of cupboard shall be taken as front area of shutters only):
Providing and fixing in position built-up cupboard, shutters with 19 mm thick pre-laminated block board of BWP Grade, Decorative Type (BWP-DEC) of approved quality or equivalent stamped with IS-1659:2004 (Latest Edition) and pre-lamination should conform to IS-2046:1995 (Latest Edition) and 3 mm thick teak wood lipping at all edges of the board with polish/ enamel paint fixed with water resistant adhesive on inside and external face as per approved shade including piano type hinges 19x25mm, magnetic ball catchers, brass tower bolt, knobs, handles with S.S. roses 150mm x 19mm diameter (Ref. Make - DORSET, Model - IP 06 PR SS or approved equivalent) and frame size 50x35 mm in 2nd class teak wood as per drawing complete including spirit polishing/ enamel painted on frame & lipping in required shade matching to the laminate, fixing of frame to wall with hold fasts, 1:2:4 RCC etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Measurement of cupboard shall be taken as front area of shutters only): For kitchen under slab cabinets.
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-Charge. [Note: For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.]
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per directions of the Engineer-in-Charge. [Note: Door handle, lock and stopper to be included in this item only].
Providing and fixing sensor based sliding glass door system of approved make for main entrance door of size 2.0m x 2.4m, comprising of D.C. Motor controller, transmission belt, aluminum profile, sensor and necessary accessories including 10mm thick toughened glass with required framing, fittings, accessories etc. complete in all respect as per manufacturer's specifications, drawings and directions of the Engineer-in-Charge.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directions of the Engineer-in-Charge :
a) 20 mm nominal outer dia pipes
b) 25 mm nominal outer dia pipes
c) 32 mm nominal outer dia pipes
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per directions of the Engineer-in-Charge :
a) 20 mm nominal dia pipes
b) 25 mm nominal dia pipes
c) 32 mm nominal dia pipes
d)100 mm nominal dia pipes
e)150 mm nominal dia pipes
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer : 18 mm thick
Providing and fixing IS:12817 marked stainless steel butt hinges with stainless steel screws etc. complete :
a) 100X58X1.90 mm
b) 75x47x1.70 mm
Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings- Type IV DIstribution Board : Double Door Translucent Euro DB of Havells or approved make as per appendix -1, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification.
Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings-Type II Distribution Board : Double Door EURODB of Havells or approved make as per appendix -1 make having Copper bus bar 100 A TPN, 1 Incomer 32 A TPN MCB with 32 A TPN RCCB (Senstivity 100 mA) alongwith 6 numbers 6 A SP MCB + 6 number 16 A SP MCB as per specification.
Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings(Type V Distribution Board : Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification)
LT Cables FRLSH - Copper Cables-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%-CU,2CX10 mm²,2XWY
Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications.(12" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect. )
Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor.(1 light point controlled by 1 switch)
Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor.(2 light points controlled by 1 switch)
Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor.(3 light points controlled by 1 switch )
Point wiring Supplying, installation and testing with (Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specifications and drawings)(Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets).
Point wiring Supplying, installation and testing with (Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st plug point for multiple exhaust fans in one circuit. )
Point wiring Supplying, installation and testing with(Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade including earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan including providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit.)
Point wiring Supplying, installation and testing with(Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box)
Point wiring Supplying, installation and testing with( Wiring as in item no. 1 for call bell points (1 call bell point controlled by 1 modular switch)in switch box including providing call bell / buzzer suiable for single phase 230 V as per specifications and drawings.)
Point wiring Supplying, installation and testing with(Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 3 numbers, 6 A 5 pin modular sockets and 10 A modular switches for UPS point as per specifications and drawings )
Excavation in unpaved ares of earth in the work sites for cables trenches for a depth upto 1.5 meters including shoring, strutting etc. (if necessary), backfilling the trench after cable laying with excavated earth or sand within the work sites complete in all respects including consumables, tools/ equipments and labour. The work shall be performed as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer.
LT Cables FRLSH - Aluminium Cables-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%(Al,3.5Cx70 mm²)
Supplying and spreading of approved quality, fine, dry river sand in cable trenches after cable laying complete in all respects including consumables, tools/ equipment and labour as per specifictions, drawings and directions of Engieer-in-charge / Site Engineer.
Supply and laying of approved quality 75 mm. thick second class brick flat soling with sand filling in the interestices, in cable trenches for protection of laid cables in all respects including consumables, tools/ equipments and labour as per specifications, drawings and directions of Engieer-in-charge/ Site engineer.
CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grade control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glands, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying. (3-1/2 x 50 sq.mm. Al power cable)
CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grade control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glands, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying.(3-1/2 x 35 sq.mm. Al power cable)
Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge (Power cables LT : OD above 20 mm and upto 40 mm)
PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc.(PVC Conduit 19 mm)
PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc.(PVC Conduit 25 mm)
PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc.(PVC Conduit 32 mm)
Supply erection and installation of cable conduits made up of GI pipes of medium class, subject to owner's approval, in already made trenches, on walls, concrete structures etc. including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees, etc. The job also includes bending, threading, binding, clamping, providing spacere, plugs, packings, bushing etc. as required for laying of cables, complete in all respects including consumables, tools/ equipments and labour a per specifications, drawings and directions of Engieer-in-charge/ Site Engineer.(GI pipe (dia 100 mm))
Supply erection and installation of cable conduits made up of GI pipes of medium class, subject to owner's approval, in already made trenches, on walls, concrete structures etc. including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees, etc. The job also includes bending, threading, binding, clamping, providing spacere, plugs, packings, bushing etc. as required for laying of cables, complete in all respects including consumables, tools/ equipments and labour a per specifications, drawings and directions of Engieer-in-charge/ Site Engineer.(GI pipe (dia 37 mm))
Supply,fixing and connection of Philips/approved equivalent make LED Slim Panel Round/Squaresuitable for Recessed / Surface mounting made of diecast alluminium body with powder coating, acrylic diffuser with Driver asperIS:15885 (Part2/Sec13):2012,operatingvoltaGE-VentureranGE- Ventureof150to265VoltsAC,P.F>0.9,SurGE-Venture protection:2KV,THD<10%,withhighpowerLED'shaving efficacyof>100lumins/watt,CCT:3000K-5700K,minimum CRI>70,.etc.,completeincluding supply&fixingofleadin wire,nuts,bolts,screwsetc.Allcompletewithlabourand materials as per directions of Engineer-in-Charge.40W (600MMX600MM) SQUARE TYP
Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications.(LED Ceiling Point: Supply and fixing of surface mounted LED ceiling light fitting type Mainstream spot Aura 15W of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation )
Exhaust fan Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greaves or of approved make as per appendix -1 fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications, drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete.-12" Sweep
EARTHING GRID (GI Strip):Supply, installation and testing or completely making the earthing grid system by supplying, laying the G.I. Strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc. complete in all respects including consumables, tools/ equipments and labour as per specifications, drawings and directions of Engineer-in-charge / Site Engineer.-40 mm x 5 mm GI Strip
Supply of below given M/s Philips or equivalent make lamps for installation in lighting fittings / fixtures as per directions of EIC. LED Tube light(18 Watt)
R.K. Electricals and Interiors
aeiforia constructions pvt ltd
E-VERVE DESIGN
CREATORS ENGINEERS & INTERIORS
Tatva Interiors and Contractors Pvt. Ltd.
VAISHNO CONTRACTS PRIVATE LIMITED
GRID INTERIORS PVT LTD
craftech infra projects llp
DD INFRAPROJECTS
VASTU SADAN AND ASSOCIATES
Dezinetree Projects Private Limited
CACTUS PROFILES PVT LTD
Mahua Enterprises
LUHAIF DEVELOPERS
gridengineers
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .