| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LRejected-Finance | L1 | Rejected-Finance EMD REFUND ONLY | |
| 2 | L2₹5.9 L+₹26,387.13 (4.67%)Rejected-Finance | L2 | Rejected-Finance EMD REFUND ONLY | |
| 3 | L3₹6.0 L+₹39,345.33 (6.96%)Rejected-Finance | L3 | Rejected-Finance EMD REFUND ONLY | |
| 4 | L4₹6.9 L+₹1.2 L (21.7%)Rejected-Finance | L4 | Rejected-Finance EMD REFUND ONLY | |
| 5 | L5₹7.1 L+₹1.4 L (25.1%)Rejected-Finance | L5 | Rejected-Finance EMD REFUND ONLY |
Tender Value
₹6.4 L
EMD Value
₹13,000
Closing Date
7 Jun 2021, 5:00 pmClosed
EE Provl. Divn. PWD B and R Narnaul
EE Provl. Divn. PWD B and R Narnaul
Special repair of PHC (Health and Wellness Centre) building at village Dhanunda in Mohindergarh District. (Re-invited)
2021_HRY_172210_1
7-PHC Dhanunda (Rs. 6.42 lakh) Re-invited
Open Tender
Civil Works - Buildings
Item-rate/Agreement basic
90 days
Works
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹13,000
Yes
26 Jul 2021
19 May 2021
8 Jun 2021
19 May 2021
7 Jun 2021
19 May 2021
Amount
Terracing consisting of tiles 22.86 cm x 11.43 Cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13).
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing, (b) in cement (HSR 8.5 b)
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. (HSR 13.64)
Dismantling Concrete, cement concrete plain 1:2: 4 mi (HSR 8.6 d)
Dismatnling Roofing, Stripping and stacking slates or tiles of a roof (HSR 8.10)
Dismantling Roofing, Dismantling steel work upto a height between ridge and floor level upto 5 metres in single section including dismembering, (a) R.S. Joists (HSR 8.21 a)
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement but including centering and shuttering laid in position complete in all respects. (HSR 10.82 + 10.95 (a)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including Straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths /storeys/ basements etc. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (HSR 18.22).
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (HSR 11.7)
First class brick work laid in cement sand mortar 1:6 in foundation plinth. (HSR 11.2)
Distempering with washable oil bound distemper (of approved manufacture) two coats on old distempered work. (HSR 16.60)
Providing and fixing glass strips, 3 mm thick in floors, (b) 32 mm wide (HSR 14.79 b)
12mm thick cement plaster on walls (1:6). (HSR 15.7).
15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. (HSR 15.12).
Providing two coats of exterior acrylic emulsion paint. (HSR 16.79) (b)
Cement Concrete Flooring, Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 14.13)
Plastering on under side of Ceiling, 10 mm thick cement plaster 1:4 (HSR 15.52)
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81).
Sachin Sharma
The Ishwar Singh Co. Multipurpose Society Ltd.
Varun Sharma
Ami Lal
PITAMBER GOYAL
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .