Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹9.4 L (6.13%)Admitted-Finance 2 NEW ROAD RATLAM RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | ₹1.6 Cr+₹9.4 L (6.13%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Ineligible |
| Sl No | Description | Qty | Unit | G. D. Anklesaria & Co. L2 | Relyaxis Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Round the clock operation and up keep of DG Sets as per Annexure -A by deploying following minimum staff as per qualification and experience attached as per Annexure C i/c all days and holidays etc.complete as required,. a) Supervisor ( HIGH Skilled) - 1 No.
b) DG Operator ( skilled) - 7 No. c) Assistant (Un skilled) - 4 No. | 12 | Months | 8,33,812 ₹1,00,05,744 | 7,22,480 ₹86,69,760 Lowest |
| 2.00Providing maintenance i/c preventive maintenance as recommended by OEM ( to be executed through OEM/Authorized Service Agents only) as per following i/c attending break downs etc, as and when required as per scope in Annexure -B attached with Monthly preventive maintenance visits. Unlimited Break down calls..Maintenance of DG Set will be carried out as per manufacturers standard practices. B- check (Only 1 No's) at 300 HRS. or 6 month. (1 job.) C- check ( Only 1 No's) at 600 Hrs. or 1 year wich ever is earlier (1 Job.) | |||||
| 2.10 | 2000 KVA DG set installed at DG Room of main service building - 4 Nos. | 12 | Months | 3,02,823 ₹36,33,876 Lowest | 3,19,450 ₹38,33,400 |
| 2.20 | 1010 KVA DG set installed at DG Room of main service building & Library Service building - 3 Nos. | 12 | Months | 1,22,385 ₹14,68,620 | 1,19,850 ₹14,38,200 Lowest |
| 2.30 | 500 KVA DG set installed at DG Room of Hostel service building -01 Nos. | 12 | Months | 49,841 ₹5,98,092 | 39,120 ₹4,69,440 Lowest |
| 2.40 | 250 KVA DG set installed at DG Room of Housing service building - 01 Nos. | 12 | Months | 23,668 ₹2,84,016 Lowest | 30,550 ₹3,66,600 |
| 3.00 | SITC of Neutral contractor of 2000 KVA DG set to be verified by OEM complete as required. | 1 | Each | 1,35,700 ₹1,35,700 Lowest | 4,65,720 ₹4,65,720 |
| 4.00 | SITC of VMR relay Model number S2vmr -3 suitable for 1010 KVA DG set to be verified by OEM complete as required. | 3 | Each | 27,140 ₹81,420 | 12,450 ₹37,350 Lowest |
| 5.00 | SITC of Battery pulse lite 12V 160AH for 1010 KVA DG set part no. AX1012845 With buyback old battery complete as required. | 2 | Each | 42,066 ₹84,132 | 26,500 ₹53,000 Lowest |
| 6.00 | SITC of Battery pulse lite 12V 65AH for 250 KVA DG set part no. AX1012843 With buyback old battery complete as required. | 2 | Each | 17,640 ₹35,280 Lowest | 24,865 ₹49,730 |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
25 Aug 2025, 3:00 pmClosed
Superintending Engineer, AIIMS Bhopal.
Office of the Superintending Engineer, 4th Floor, Kautilya Bhawan, AIIMS, Saket Nagar, Bhopal, 462020.
Annual Operation, Maintenance and Repair of DG Sets of different capacity Installed at AIIMS Bhopal.
2025_IMSBP_870849_1
02/NIT/ SE/E/ABEU/AIIMS/BPL/2025-26
Open Tender
Electrical Works
Item Rate
365 days
AIIMS
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.3 L
Office of the Superintending Engineer,AIIMS Bhopal
20 Sept 2025
29 Jul 2025
26 Aug 2025
29 Jul 2025
25 Aug 2025
9 Aug 2025
4 Aug 2025
Amount
Round the clock operation and up keep of DG Sets as per Annexure -A by deploying following minimum staff as per qualification and experience attached as per Annexure C i/c all days and holidays etc.complete as required,. a) Supervisor ( HIGH Skilled) - 1 No. b) DG Operator ( skilled) - 7 No. c) Assistant (Un skilled) - 4 No.
Providing maintenance i/c preventive maintenance as recommended by OEM ( to be executed through OEM/Authorized Service Agents only) as per following i/c attending break downs etc, as and when required as per scope in Annexure -B attached with Monthly preventive maintenance visits. Unlimited Break down calls..Maintenance of DG Set will be carried out as per manufacturers standard practices. B- check (Only 1 No's) at 300 HRS. or 6 month. (1 job.) C- check ( Only 1 No's) at 600 Hrs. or 1 year wich ever is earlier (1 Job.)
2000 KVA DG set installed at DG Room of main service building - 4 Nos.
1010 KVA DG set installed at DG Room of main service building & Library Service building - 3 Nos.
500 KVA DG set installed at DG Room of Hostel service building -01 Nos.
250 KVA DG set installed at DG Room of Housing service building - 01 Nos.
SITC of Neutral contractor of 2000 KVA DG set to be verified by OEM complete as required.
SITC of VMR relay Model number S2vmr -3 suitable for 1010 KVA DG set to be verified by OEM complete as required.
SITC of Battery pulse lite 12V 160AH for 1010 KVA DG set part no. AX1012845 With buyback old battery complete as required.
SITC of Battery pulse lite 12V 65AH for 250 KVA DG set part no. AX1012843 With buyback old battery complete as required.
G. D. Anklesaria & Co. (BID ID -3267054)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .